A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

One year clinical results of photoastigmatic refractive keratectomy for compound myopic astigmatism. | LitMetric

Purpose: To evaluate the efficacy, predictability, and safety of excimer laser photoastigmatic refractive keratectomy (PARK) to correct compound myopic astigmatism.

Setting: Departments of Ophthalmology, Robert Debré Hospital and Rothschild Foundation, Paris, France.

Methods: This retrospective study included 27 eyes with compound myopic astigmatism treated with a Nidek EC 5000 excimer laser. The refractive results were measured at 1 year, and the cylindrical component was analyzed by the Alpins method. Mean preoperative myopia was -4.50 diopters (D) (range -0.75 to -4.00 D) and mean preoperative cylinder, -1.64 D (range -0.75 to -4.00 D).

Results: At 1 year, the spherical equivalent was -0.47 D (range +1.00 to -3.00 D) and residual subjective astigmatism, -0.40 (range -0.25 to -1.50 D). Uncorrected visual acuity of 20/40 or better was obtained in 22 of the 27 eyes; 21 eyes were within +/- 1.0 D of emmetropia. Vector analysis showed a mean coefficient adjustment of 1.50 D +/- 0.53 (SD), a mean axis shift of 2.64 +/- 12.10 degrees, and a mean magnitude of error of 0.45 +/- 0.56 D. Haze was absent in 22 eyes and grade 1+ in 5 eyes. Five eyes gained 1 line of best corrected visual acuity and 3 lost 1 line. No patient lost more than 1 line.

Conclusion: Excimer laser PARK successfully corrected low and moderate myopia combined with up to 4.0 D of astigmatism with a low mean angle of error. To increase the accuracy of toric ablation, specific algorithms for the cylinder component are needed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0886-3350(99)00072-3DOI Listing

Publication Analysis

Top Keywords

compound myopic
12
excimer laser
12
photoastigmatic refractive
8
refractive keratectomy
8
myopic astigmatism
8
range -075
8
-075 -400
8
visual acuity
8
eyes eyes
8
eyes
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!