Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the efficacy, predictability, and safety of excimer laser photoastigmatic refractive keratectomy (PARK) to correct compound myopic astigmatism.
Setting: Departments of Ophthalmology, Robert Debré Hospital and Rothschild Foundation, Paris, France.
Methods: This retrospective study included 27 eyes with compound myopic astigmatism treated with a Nidek EC 5000 excimer laser. The refractive results were measured at 1 year, and the cylindrical component was analyzed by the Alpins method. Mean preoperative myopia was -4.50 diopters (D) (range -0.75 to -4.00 D) and mean preoperative cylinder, -1.64 D (range -0.75 to -4.00 D).
Results: At 1 year, the spherical equivalent was -0.47 D (range +1.00 to -3.00 D) and residual subjective astigmatism, -0.40 (range -0.25 to -1.50 D). Uncorrected visual acuity of 20/40 or better was obtained in 22 of the 27 eyes; 21 eyes were within +/- 1.0 D of emmetropia. Vector analysis showed a mean coefficient adjustment of 1.50 D +/- 0.53 (SD), a mean axis shift of 2.64 +/- 12.10 degrees, and a mean magnitude of error of 0.45 +/- 0.56 D. Haze was absent in 22 eyes and grade 1+ in 5 eyes. Five eyes gained 1 line of best corrected visual acuity and 3 lost 1 line. No patient lost more than 1 line.
Conclusion: Excimer laser PARK successfully corrected low and moderate myopia combined with up to 4.0 D of astigmatism with a low mean angle of error. To increase the accuracy of toric ablation, specific algorithms for the cylinder component are needed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0886-3350(99)00072-3 | DOI Listing |