We investigated the idea that the cerebellum is required for precise timing of fast skilled arm movements by studying one situation where timing precision is required, namely finger opening in overarm throwing. Specifically, we tested the hypothesis that in overarm throws made by cerebellar patients, ball high-low inaccuracy is due to disordered timing of finger opening. Six cerebellar patients and six matched control subjects were instructed to throw tennis balls at three different speeds from a seated position while angular positions in three dimensions of five arm segments were recorded at 1,000 Hz with the search-coil technique. Cerebellar patients threw more slowly than controls, were markedly less accurate, had more variable hand trajectories, and showed increased variability in the timing, amplitude, and velocity of finger opening. Ball high-low inaccuracy was not related to variability in the height or direction of the hand trajectory or to variability in finger amplitude or velocity. Instead, the cause was variable timing of finger opening and thereby ball release occurring on a flattened arc hand trajectory. The ranges of finger opening times and ball release times (timing windows) for 95% of the throws were on average four to five times longer for cerebellar patients; e.g., across subjects mean ball release timing windows for throws made under the medium-speed instruction were 11 ms for controls and 55 ms for cerebellar patients. This increased timing variability could not be explained by disorder in control of force at the fingers. Because finger opening in throwing is likely controlled by a central command, the results implicate the cerebellum in timing the central command that initiates finger opening in this fast skilled multijoint arm movement.

Download full-text PDF

Source
http://dx.doi.org/10.1152/jn.1999.82.1.103DOI Listing

Publication Analysis

Top Keywords

finger opening
32
cerebellar patients
24
ball high-low
12
high-low inaccuracy
12
ball release
12
finger
9
timing
9
opening
8
overarm throws
8
fast skilled
8

Similar Publications

Objective: To explain design features of scissors and surgical instruments that work against left-handed users and demonstrate how the user can adapt their technique for ambidextrous use of standard instruments.

Animals: Any species.

Methods: Standard instruments are designed for maximal efficiency with the use of a right-handed grip.

View Article and Find Full Text PDF

While myoelectric control has been commercialized in prosthetics for decades, its adoption for more general human-machine interaction has been slow. Although high accuracies can be achieved across many gestures, current control approaches are prone to false activations in real-world conditions. This is because the same electromyogram (EMG) signals generated during the elicitation of gestures are also naturally activated when performing activities of daily living (ADLs), such as when driving to work or while typing on a keyboard.

View Article and Find Full Text PDF

. The current paper describes the creation of a simultaneous trimodal neuroimaging protocol. The authors detail their methodological design for a subsequent large-scale study, demonstrate the ability to obtain the expected physiologically induced responses across cerebrovascular domains, and describe the pitfalls experienced when developing this approach.

View Article and Find Full Text PDF

Lichen planus is an inflammatory disease that affects the skin and mucous membranes, and although rare, it can manifest in the vulvar region. Vulvar lichen planus can occur in women of reproductive age and may cause vulvar adhesion, potentially complicating examinations and delivery during pregnancy. We report a case in which a pregnant woman with vulvar adhesion due to vulvar lichen planus successfully delivered vaginally following labiaplasty.

View Article and Find Full Text PDF

Background: Stroke is the leading cause of acquired motor deficiencies in adults. Restoring prehension abilities is challenging for individuals who have not recovered active hand opening capacities after their rehabilitation. Self-triggered functional electrical stimulation applied to finger extensor muscles to restore grasping abilities in daily life is called grasp neuroprosthesis (GNP) and remains poorly accessible to the post-stroke population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!