This study evaluates the efficacy of gadobentate-dimeglumine (Gd-BOPTA) for enhancement of liver signal-to-noise ratio (SNR) and lesion-liver contrast-to-noise ratio (CNR) on T1-weighted spin-echo (SE) and gradient-recalled-echo (GRE) images at two different doses. Fifty patients with known or suspected liver lesions were examined at 1.5 T. T1-weighted SE (TR/TE 300/12 msec) and GRE images (TR/TE80/4.2 msec/flip angle 80 degrees) were obtained before and at 40-80 minutes and 90-120 minutes after administration of 0.05 or 0.1 mmol/kg Gd-BOPTA. Quantitative measurements of tissue signal intensity were performed at each dose. Liver showed significant enhancement after Gd-BOPTA on T1-weighted SE and GRE images (0.05 mmol: P < 0.05; 0.1 mmol: P < 0.001). The dose of 0.1 mmol/kg provided higher liver SNR than 0.05 mmol/kg. Mean liver SNR was higher on GRE than SE images (P < 0.0001). Lesion-liver CNR significantly increased on GRE images after 0.1 mmol (P < 0.05). There was a trend toward superiority of 0.1 mmol over 0.05 mmol/kg. GRE images were superior to SE images for pre- and post Gd-BOPTA lesion-liver CNR (P < 0.05). Our study suggests that Gd-BOPTA provides prolonged enhancement of liver SNR and CNR, that a dose of 0.1 mmol/Kg appears to be superior than 0.05 mmol/Kg, and that GRE techniques should be used in preference over SE techniques.

Download full-text PDF

Source
http://dx.doi.org/10.1002/(sici)1522-2586(199907)10:1<80::aid-jmri11>3.0.co;2-sDOI Listing

Publication Analysis

Top Keywords

gre images
24
005 mmol/kg
16
mmol 005
12
liver snr
12
gd-bopta quantitative
8
images
8
images doses
8
enhancement liver
8
005
8
005 mmol
8

Similar Publications

Background: Splenic stiffness is a potential imaging marker of portal hypertension. Normative spleen stiffness values are needed to define diagnostic thresholds.

Objective: To report stiffness measurements of the spleen in healthy children undergoing liver magnetic resonance (MR) elastography across MRI vendors and field strengths.

View Article and Find Full Text PDF

Objectives: Brain metastases are the most common intracranial malignancy in adults, and their detection is crucial for treatment planning. Post-contrast 3D T1 gradient-recalled echo (GRE) sequences are commonly used for this purpose, but contrast-enhanced 3D T1 turbo spin-echo (TSE) sequences with motion-sensitized driven-equilibrium (MSDE) technique ("black blood") may offer improved detection. This study aimed to compare the effectiveness of contrast-enhanced 3D black blood sequences to standard 3D T1 GRE sequences in detecting brain metastases on a 1.

View Article and Find Full Text PDF

χ-sepnet: Deep Neural Network for Magnetic Susceptibility Source Separation.

Hum Brain Mapp

February 2025

Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea.

Magnetic susceptibility source separation (χ-separation), an advanced quantitative susceptibility mapping (QSM) method, enables the separate estimation of paramagnetic and diamagnetic susceptibility source distributions in the brain. Similar to QSM, it requires solving the ill-conditioned problem of dipole inversion, suffering from so-called streaking artifacts. Additionally, the method utilizes reversible transverse relaxation ( ) to complement frequency shift information for estimating susceptibility source concentrations, requiring time-consuming data acquisition for (e.

View Article and Find Full Text PDF

Background: Several factors can impair image quality and reliability of liver magnetic resonance elastography (MRE), such as inadequate driver positioning, insufficient wave propagation and patient-related factors.

Purpose: To report initial results on automatic classification of liver MRE image quality using various deep learning (DL) architectures.

Study Type: Retrospective, single center, IRB-approved human study.

View Article and Find Full Text PDF

Background: There is evidence that iron metabolism may play a role in the underlying pathophysiological mechanism of migraine. Studies using (=1/ ) relaxometry, a common MRI-based iron mapping technique, have reported increased values in various brain structures of migraineurs, indicating iron accumulation compared to healthy controls.

Purpose: To investigate whether there are short-term changes in during a migraine attack.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!