A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of on-line endocardial border detection on determination of left ventricular volume and ejection fraction by transthoracic 3-dimensional echocardiography. | LitMetric

This study was performed to determine whether use of on-line automated border detection (ABD) could reduce data analysis time for 3-dimensional echocardiography (3DE) while maintaining accuracy of 3DE in measures of left ventricular (LV) volumes and ejection fraction (EF). The study proceeded in 2 phases. In the validation phase, 20 subjects were examined with the use of 3DE and of monoplane 2-dimensional (2D) ABD. Results were compared with the reference standard of magnetic resonance imaging (MRI). In the test phase, 20 subjects underwent two 3DE studies (once with images optimized for visual border definition and once with images optimized for ABD border tracking) and a conventionally used 2D ABD study. For 3DE, volumes and EF were determined with the use of manually traced borders and ABD. Analysis times were recorded with a digital stopwatch. In the validation phase, 3DE and MRI results correlated very well (r = 0.99) without systematic differences. Comparison of 2D ABD with MRI showed good correlation for LV volumes (r >/= 0.90) and EF (r = 0.85) despite significant underestimation. For the test phase, Acoustic Quantification-optimized 3-dimensional datasets underestimated end-diastolic volume and EF relative to visually optimized 3-dimensional datasets regardless of whether borders were hand-traced or ABD was used. However, correlations ranged from r = 0.96 to r = 0.98 for LV volumes and 0.88 to 0.91 for LV EF and were superior to those for 2D ABD. Data analysis times decreased moderately with the use of ABD, but scan times increased; total study times were unchanged. Use of on-line ABD with 3DE reduces data analysis time and is more accurate than conventional monoplane 2D ABD but results in underestimation of LV volumes and EF. Additional automated postprocessing techniques may be required to obtain accurate measures, consistently using 3DE in conjunction with on-line ABD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0894-7317(99)70002-7DOI Listing

Publication Analysis

Top Keywords

abd
12
data analysis
12
border detection
8
left ventricular
8
ejection fraction
8
3-dimensional echocardiography
8
analysis time
8
3de
8
validation phase
8
phase subjects
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!