A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Near-infrared spectroscopy for bioprocess monitoring and control. | LitMetric

Near-infrared spectroscopy for bioprocess monitoring and control.

Biotechnol Bioeng

Centre for Advanced Instrumentation Systems, University College London, Torrington Place, London.

Published: June 1999

This article describes the calibration of a spectroscopic scanning instrument for the measurement of selected contaminants in a complex biological process stream. Its use is for the monitoring of a process in which contaminants are to be removed selectively by flocculation from yeast cell homogenate. The main contaminants are cell debris, protein, and RNA. A low-cost instrument has been developed for sensitivity in the region of the NIR spectrum (from 1900 to 2500 nm) where preliminary work found NIR signatures from cell debris, protein, and RNA. Calibration models have been derived using a multivariate method for concentrations of these contaminants, such as would be found after the flocculation process. Two strategies were compared for calibrating the NIR instrument. In one case, samples were prepared by adding materials representative of the contaminants to clarified yeast homogenate so the contaminant levels were well known but outside the range of interest. In the other case, where samples were like those from the process stream after flocculation and floc removal, there was uncertainty of analysis of contaminant level, but the calibration was in the range of interest. Calibration using process stream samples gave results close to those derived from traditional assays. When the calibration models were used to predict the contaminant concentrations in previously unseen samples, the correlation coefficients between measurements and predictions were above 90% in all cases but one. The prediction errors were similar to the errors in the traditional assays.

Download full-text PDF

Source
http://dx.doi.org/10.1002/(sici)1097-0290(19990620)63:6<684::aid-bit6>3.0.co;2-qDOI Listing

Publication Analysis

Top Keywords

process stream
12
cell debris
8
debris protein
8
protein rna
8
calibration models
8
case samples
8
range interest
8
traditional assays
8
calibration
5
contaminants
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!