Estimation of respiratory volumes from the photoplethysmographic signal. Part 2: A model study.

Med Biol Eng Comput

Department of Biomedical Engineering, Linköping University, Sweden.

Published: January 1999

A Windkessel model has been constructed with the aim of investigating the respiratory-volume dependence of the photoplethysmographic (PPG) signal. Experimental studies show a correlation between respiratory volume and the peak-to-peak value of the respiratory-induced intensity variations (RIIV) in the PPG signal. The model compartments are organised in two closed chambers, representing the thorax and the abdomen, and in a peripheral part not directly influenced by respiration. Cardiac pulse and respiration are created by continuous adjustment of the pressures in the affected compartments. Together with the criteria for heart and venous valves, the model is based on a set of 17 differential equations. These equations are solved for varying thoracic and abdominal pressures corresponding to different respiratory volumes. Furthermore, a sensitivity analysis is performed to evaluate the properties of the model. The PPG signals are created as a combination of peripheral blood flow and pressure. From these signals, the respiratory synchronous parts are extracted and analysed. To study some important limitations of the model, respiratory type and rate are varied. From the simulations, it is possible to verify our earlier experimental results concerning the relationship between respiratory volume and the peak-to-peak value of the RIIV signal. An expected decrease in the amplitude of the respiratory signal with increased respiratory rate is also found, which is due to the lowpass characteristics of the vessel system. Variations in the relationship between thoracic and abdominal respiration also affect the RIIV signal. The simulations explain and verify what has been found previously in experimental studies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02513265DOI Listing

Publication Analysis

Top Keywords

respiratory volumes
8
signal model
8
ppg signal
8
experimental studies
8
respiratory volume
8
volume peak-to-peak
8
thoracic abdominal
8
riiv signal
8
respiratory
7
signal
6

Similar Publications

Free-Breathing Respiratory Triggered High-Pitch Lung CT: Insights From Phantom and Patient Scans.

Invest Radiol

January 2025

From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).

Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.

View Article and Find Full Text PDF

Individuals with Preserved Ratio Impaired Spirometry (PRISm), defined as FEV/FVC ≥0.7 and FEV1 <80% predicted, are at higher risk of developing COPD. However, data for Australian adults are limited.

View Article and Find Full Text PDF

Purpose: Conventional radiotherapy (CRT) has limited local control and poses a high risk of severe toxicity in large lung tumors. This study aimed to develop an integrated treatment plan that combines CRT with lattice boost radiotherapy (LRT) and monitors its dosimetric characteristics.

Methods: This study employed cone-beam computed tomography from 115 lung cancer patients to develop a U-Net +  + deep learning model for generating synthetic CT (sCT).

View Article and Find Full Text PDF

COVID-19 infection has been linked to ocular involvement, particularly retinal microvascular changes. Additionally, prolonged hypoxemia may affect retinal sublayers located within the retinal watershed zone. The aim of this study was to evaluate retinal and optic nerve OCT parameters in patients with COVID-19 illness of varying severity and compare them with controls.

View Article and Find Full Text PDF

Global oxygen minimum zones (OMZs) often reach hypoxia but seldom reach anoxia. Recently it was reported that Michaelis Menten constants (K) of oxidative enzymes are orders of magnitude higher than respiratory K values, and in the Hypoxic Barrier Hypothesis it was proposed that, in ecosystems experiencing falling oxygen, oxygenase enzyme activities become oxygen-limited long before respiration. We conducted a mesocosm experiment with a phytoplankton bloom as an organic carbon source and controlled dissolved oxygen (DO) concentrations in the dark to determine whether hypoxia slows carbon oxidation and oxygen decline.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!