A novel computed tomographic (CT) technique used for the instantaneous measurement of the dynamic elastic modulus of intact excised porcine aortic vessels subjected to physiological pressure waveforms is described. This system was comprised of a high resolution X-ray image intensifier based computed tomographic system with limiting spatial resolution of 3.2 mm-1 (for a 40 mm field of view) and a computer-controlled flow simulator. Utilising cardiac gating and computer control, a time-resolved sequence of 1 mm thick axial tomographic slices was obtained for porcine aortic specimens during one simulated cardiac cycle. With an image acquisition sampling interval of 16.5 ms, the time sequences of CT slices were able to quantify the expansion and contraction of the aortic wall during each phase of the cardiac cycle. Through superficial tagging of the adventitial surface of the specimens with wire markers, measurement of wall strain in specific circumferential sectors and subsequent calculations of localised dynamic elastic modulus were possible. The precision of circumferential measurements made from the CT images utilising a cluster-growing segmentation technique was approximately +/- 0.25 mm and allowed determination of the dynamic elastic modulus E(dyn) with a precision of +/- 8 kPa. Dynamic elastic modulus was resolved as a function of the harmonics of the physiological pressure waveform and as a function of the angular position around the vessel circumference. Application of this dynamic CT (DCT) technique to seven porcine thoracic aortic specimens produced a circumferential average (over all frequency components) E(dyn) of 373 +/- 29 kPa. This value was not statistically different (p < 0.05) from the values of 430 +/- 77 and 390 +/- 47 kPa obtained by uniaxial tensile testing and volumetric measurements respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF02513260 | DOI Listing |
J Biomech Eng
January 2025
State Key Laboratory of Fluid Power and Mechatronic Systems, Department of Mechanical Engineering, Zhejiang University, Hangzhou, 315000, China.
Due to individual differences, accurate identification of tissue elastic parameters is essential for biomechanical modeling in surgical guidance for hepatic venous injections. This paper aims to acquire the absolute Young's modulus of heterogeneous soft tissues during endoscopic surgery with 2D ultrasound images. First, we introduced a force-sensor-less approach that utilizes a pre-calibrated soft patch with a known Young's modulus and its ultrasound images to calculate the external forces exerted by the probe on the tissue.
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
January 2025
Vascular Biology Center and Department of Medicine, Medical College of Georgia at Augusta University, Augusta, GA USA.
The contribution of sex hormones to cardiovascular disease, including arterial stiffness, is established; however, the role of sex chromosome interaction with sex hormones, particularly in women, is lagging. Arterial structural stiffness depends on the intrinsic properties and transmural wall geometry that comprise a network of cells and extracellular matrix (ECM) proteins expressed in a sex-dependent manner. In this study, we used four-core genotype (FCG) mice to determine the relative contribution of sex hormones versus sex chromosomes or their interaction with arterial structural stiffness.
View Article and Find Full Text PDFJ Acoust Soc Am
January 2025
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.
View Article and Find Full Text PDFNanoscale
January 2025
National Engineering Research Center for Colloidal Materials, School of Chemistry & Chemical Engineering, Shandong University, Jinan 250100, P. R. China.
The controllable synthesis of monodisperse mesoporous silica microspheres with unique physicochemical properties is becoming increasingly important for a variety of applications such as catalysts, chromatography, drug delivery and sensors. Here, we report a facile microfluidic-assisted sol-gel method for the preparation of silica microspheres with precisely controlled properties such as the size of the microspheres, the surface morphology, porosity and stiffness. All these properties can be manipulated by changing specific synthesis parameters, such as changing the microfluidic channels to tune the size of the microdroplets (tens to hundreds of microns), changing the contents of the precursor solution to manipulate the surface morphology (wrinkled to smooth surface) and changing the gelation/annealing conditions to tune the porosity (surface area up to 1021 m g) and stiffness of the microspheres (elastic modulus tunable from 0.
View Article and Find Full Text PDFSoft Matter
January 2025
Leibniz-Institut für Polymerforschung Dresden e.V., Hohe Strasse 6, Dresden, 01069, Germany.
Field-induced microstructure evolution can play an important role in defining the coupled magneto-mechanical response of Magneto-Active Elastomers (MAEs). The behavior of these materials is classically modeled using mechanical, magnetic and coupled magneto-mechanical contributions to their free energy function. If the MAE sample is fully clamped so it cannot deform, the mechanical coupling is reduced to the internal microscopic deformations caused by the particles moving and deforming the elastic medium that surrounds them.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!