Detection of compact low-chromatin areas in cell nuclei images.

Stud Health Technol Inform

Faculty of Electrical Engineering, University of Ljubljana, Slovenia.

Published: September 1999

When analysing some DNA stained human cell nuclei using a light microscope or an quantitative image cytometer, compact low-chromatin areas (CLCA) can be observed. We are still not certain about the meaning and source of this phenomena. To enable the detection of CLCA by an image cytometer, a special image processing algorithm has to be developed and new nuclear cell features have to be designed. The presented image processing algorithm automatically detects CLCA in nuclei cell images taken from different tissues. The algorithm is composed of many basic image processing operations. The sequence of operations is determined by a priory knowledge about the properties of CLCA as a set of heuristic roles. The calculated CLCA features are CLCA area, perimeter, average intensity, compactnes and edge sharpness. The matching of the automatic CLCA detection and manual detection (performed by a biologist) was tested using 1400 cell nuclei. The results show a 83.4% match for the nuclei without CLCA and a 93.8% match for the cells with CLCA.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cell nuclei
12
image processing
12
clca
9
compact low-chromatin
8
low-chromatin areas
8
image cytometer
8
processing algorithm
8
cell
5
nuclei
5
image
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!