Rationale And Objectives: The authors performed this study to compare the in vivo efficacies of the temporary venous spring filter and the RF02 filter in an animal model.
Materials And Methods: Either the spring filter or the RF02 filter was placed in the inferior vena cava of 10 pigs each, and two clots (5 x 20 mm) were funneled into the filters at 1-hour intervals. The second clots were funneled without removing the first clots captured by the filters. Clot-trapping ability, caval occlusion associated with the clot-trapping procedure, arterial blood gas concentrations, and changes in arterial and iliac venous pressures were evaluated.
Results: Placement of the RF02 filter caused elevation of iliac venous pressure with a maximum of 2.2 mm Hg (median) (n = 13, P = .003). Placement of the spring filter parallel to venous flow enabled capture of 90% (nine of 10) and 100% (six of six) of the first and second clots, respectively. The RF02 filter captured clots consistently. The difference between filters was not statistically significant. Both filters equally contributed to elevation of iliac venous pressure (median, 9.3 and 7.2 mm Hg [n = 9] with the spring filter and RF02 filter, respectively). Caval occlusion occurred in 17% (one of six) and 67% (six of nine) of animals after two clots were trapped in the spring filter and RF02 filter, respectively (P = .06). Other parameters were not influenced by the clot-trapping procedure.
Conclusion: Although a larger version should be developed and better stability of the filter is needed, the spring filter proved to be an efficient filtering device and had a lower rate of caval occlusion compared with the RF02 filter.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s1076-6332(99)80229-3 | DOI Listing |
bioRxiv
January 2025
Department of Mathematics, Morgan State University, 1700 E. Cold Spring Lane, Baltimore, 21251, MD, USA.
Single-cell RNA-seq analysis characterizes developmental mechanisms of cellular differentiation, lineage determination, and reprogramming with differential conditioning of the microenvironment. In this article, the underlying dynamics are formulated via optimal transport with algorithms that calculate the transition probability of the state of cell dynamics over time. The algorithmic biases of optimal transport (OT) due to entropic regularization are balanced by Sinkhorn divergence, which normally de-biases the regularized transport by centering them.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
January 2025
U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.
Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).
Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.
Appl Environ Microbiol
January 2025
Office of Applied Science, Center for Veterinary Medicine, U.S. Food and Drug Administration, Laurel, Maryland, USA.
As a diverse and complex food matrix, the animal food microbiota and repertoire of antimicrobial resistance (AMR) genes remain to be better understood. In this study, 16S rRNA gene amplicon sequencing and shotgun metagenomics were applied to three types of animal food samples (cattle feed, dry dog food, and poultry feed). ZymoBIOMICS mock microbial community was used for workflow optimization including DNA extraction kits and bead-beating conditions.
View Article and Find Full Text PDFJ Occup Environ Hyg
January 2025
Division of Field Studies and Engineering, National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), Cincinnati, Ohio.
Structural firefighters are exposed to an array of polycyclic aromatic hydrocarbons (PAHs) as a result of incomplete combustion of both synthetic and natural materials. PAHs are found in both the particulate and vapor phases in the firefighting environment and are significantly associated with acute and chronic diseases, including cancer. Using a fireground exposure simulator (FES) and standing mannequins dressed in four different firefighter personal protective equipment (PPE) conditions, each with varying levels of protective hood interface and particulate-blocking features, the efficacy of the hoods was assessed against the ingress of PAHs (specifically, naphthalene).
View Article and Find Full Text PDFPLoS One
December 2024
Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration (FDA), Silver Spring, MD, United States of America.
During the SARS-CoV-2 pandemic, a need for methods to decontaminate and reuse personal protective equipment (PPE) and medical plastics became a priority. In this investigation we aimed to develop a contamination evaluation protocol for laboratory pipette tips, after decontamination. Decontamination methods tested in this study included cleaning with a common laboratory detergent (2.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!