A prospective, randomised trial was carried out to examine the efficacy of perforate invagination (PIN, Credenhill Ltd, Derbyshire, UK) stripping of the long saphenous vein (LSV) in comparison to conventional stripping (Astratech AB, Sweden) in the surgical management of primary varicose veins. Eighty patients with primary varicosities secondary to sapheno-femoral junction (SFJ) incompetence and LSV reflux were recruited. Patients were randomised to PIN or conventional stripping with all other operative techniques remaining constant. Follow-up was performed at 1 and 6 weeks postoperatively. There were no statistically significant differences between the two techniques in terms of time taken to strip the vein, percentage of vein stripped or the area of bruising at 1 week. The size of the exit site was significantly smaller with the PIN device (P < or = 0.01). Optimal use of the conventional stripper provides results comparable to the PIN device. Choice of stripping device remains the surgeon's, bearing in mind that the PIN stripper achieves slightly better cosmesis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2503177 | PMC |
Acc Chem Res
January 2025
Helmholtz Institute Ulm (HIU) Electrochemical Energy Storage, Helmholtzstrasse 11, 89081 Ulm, Germany.
ConspectusLithium-ion batteries (LIBs) based on graphite anodes are a widely used state-of-the-art battery technology, but their energy density is approaching theoretical limits, prompting interest in lithium-metal batteries (LMBs) that can achieve higher energy density. In addition, the limited availability of lithium reserves raises supply concerns; therefore, research on postlithium metal batteries is underway. A major issue with these metal anodes, including lithium, is dendritic formation and insufficient reversibility, which leads to safety risks due to short circuits and the use of flammable electrolytes.
View Article and Find Full Text PDFNat Nanotechnol
January 2025
Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, MD, USA.
Room-temperature non-aqueous sodium metal batteries are viable candidates for cost-effective and safe electrochemical energy storage. However, they show low specific energy and poor cycle life as the use of conventional organic-based non-aqueous electrolyte solutions enables the formation of interphases that cannot prevent degradations at the positive and negative electrodes. Here, to promote the formation of inorganic NaF-rich interphases on both negative and positive electrodes, we propose the salt-in-presalt (SIPS) electrolyte formulation strategy.
View Article and Find Full Text PDFCornea
January 2025
Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
Purpose: This study aimed to describe a novel technique of direct anterior chamber (AC) air replacement (DACAR) for the management of Descemet stripping automated endothelial keratoplasty (DSAEK) in postvitrectomized eyes and eyes with previous glaucoma surgery.
Methods: DACAR was performed after a corneal donor graft was transplanted through a wound using the pull-through technique. DACAR involves stabilizing the graft with forceps while introducing air into the AC via an infusion cannula to ensure complete air exchange.
Allergy
January 2025
Department of Dermatology, Icahn School of Medicine at the Mount Sinai, New York, New York, USA.
Introduction: Chronic hand eczema (CHE) is a highly prevalent inflammatory skin condition which is often resistant to conventional treatments. Molecular insights of CHE remain limited. Tape stripping combined with high-throughput RNA sequencing can now provide a better insight into CHE pathogenesis in a minimally invasive fashion.
View Article and Find Full Text PDFRSC Adv
January 2025
Department of Freshman Engineering, PVP Siddhartha Institute of Technology Vijayawada 520007 Andhra Pradesh India.
Assessing heavy metal ion (HMI) contamination to sustain drinking water hygiene is a challenge. Conventional approaches are appealing for the detection of HMIs but electrochemical approaches can resolve the limitations of these approaches, such as tedious sample preparation, high cost, time consuming and the need for trained professionals. Here, an electrochemical approach is developed using a nano-sphered polypyrrole (PPy) functionalized with MoS (PPy/MoS) by square wave anodic stripping voltammetry for the detection of HMIs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!