The method for checking the results of measurements of the analyzed substance and the calibrator for parallelism the immunological testing kit ABICAP-test-DIPHTHERIA, produced by ABION (Germany), is described. The international standard sample of diphtheria antitoxin human serum was used as calibrator, and human serum No. 18, obtained from the Biomed Group (Russia), was used as the substance to be analyzed. The described method made it possible to detect the parallelism of "dose-response" curves with the relative error not exceeding 20%. Such accuracy proved to be sufficient for practical purposes and was in agreement with the amplitude of oscillations in measured optical densities. The shift of graphs along the abscissa made it possible to estimate the concentration of the serum as exceeding the concentration of the standard sample 2.3 times. The use of analytical approximation for the standard seems to be an important feature in the described method.

Download full-text PDF

Source

Publication Analysis

Top Keywords

substance calibrator
8
standard sample
8
human serum
8
described method
8
[the assessment
4
assessment parallelism
4
parallelism measuring
4
measuring analyzable
4
analyzable substance
4
calibrator immunological
4

Similar Publications

Resorcinol is a widespread substance used in a large variety of manufacturing industries, including cosmetics, with endocrine-disrupting activity on the thyroid function. The aim of the present study was to develop and validate a sensitive, selective and robust method to quantify resorcinol in urine and thereby assess hairdressers' occupational exposure. As resorcinol is mainly excreted in urine as glucuronide or sulfate forms, the first step consisted in hydrolyzing urine samples with a β-glucuronidase-arylsulfatase enzyme for 16 h.

View Article and Find Full Text PDF

Lipid peroxidation is a major process that determines the quality of various oil samples during their use and storage, in which the primary products are hydroperoxides (HP'). HP' are very stable compounds at ambient conditions and are harmful to human health. Therefore, the evaluation of the degree of oil oxidation is an excellent tool for ensuring food safety.

View Article and Find Full Text PDF

Background: Evidence-based mental health requires patient-relevant outcome data, but many indicators lack clinical meaning and fail to consider youth perceptions. The minimally important change (MIC) indicator designates change as meaningful to patients, yet is rarely reported in youth mental health trials.

Objective: This study aimed to establish MIC thresholds for two patient-reported outcome measures (PROMs), the Columbia Impairment Scale (CIS) and the Strengths and Difficulties Questionnaire (SDQ), using different estimation methods.

View Article and Find Full Text PDF

The performance of Upflow Anaerobic Sludge Blanket (UASB) bioreactors treating sulfate (SO) -rich effluents depends on multiple factors, including microbial interactions and operational conditions. The high complexity of these systems necessitates the use of mathematical modelling tools to better understand the process and predict the long-term impacts of various operational variables. In this work, a mathematical model describing the long-term operation of a sulfate-fed 2.

View Article and Find Full Text PDF

Recent emphasis on the development of safe-and-sustainable-by-design chemicals highlights the need for methods facilitating the early assessment of persistence. Activated sludge experiments have been proposed as a time- and resource-efficient way to predict half-lives in simulation studies. Here, this persistence "read-across" approach was developed to be more broadly and robustly applicable.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!