There are potential benefits to addition of visceral organ perfusion, by means of a 9-Fr. catheter system (octopus), to distal aortic perfusion during thoracoabdominal aneurysm surgery. However, in the literature there are reports of adverse effects. The authors therefore compared two groups of patients who underwent thoracoabdominal aneurysm surgery with and without visceral organ perfusion. In the group in which the visceral perfusion was applied, the use of platelets (26 versus 11 units; P < 0.05), fresh frozen plasma (3.4 versus 1.5 units; P < 0.05) and packed cells (20 versus 8 units, P < 0.05) was significantly increased. An equal number of patients in both groups developed renal failure postoperatively. An explanation for this adverse effect can be found in the high shear rates in the catheters used, mainly as a result of the small diameter. High shear rates cause haemolysis. Also, the flow through the catheters is insufficient to maintain adequate perfusion of the visceral organs. A higher flow in these catheters would result in an even higher shear rate. It is therefore concluded that coagulopathy and insufficient bloodflow is caused by the small internal diameter of the catheters, which renders the device insufficient.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0967-2109(98)00067-2DOI Listing

Publication Analysis

Top Keywords

thoracoabdominal aneurysm
12
aneurysm surgery
12
versus units
12
units 005
12
visceral perfusion
8
visceral organ
8
organ perfusion
8
high shear
8
shear rates
8
catheters result
8

Similar Publications

The optimal management of acute type A aortic dissection (ATAAD) remains a controversial subject. While some surgeons opt for a hemiarch approach to minimize bypass and cross-clamping time, others prefer partial or total arch replacement to prevent the need for additional operations. The advent of hybrid approaches offers a variety of options to the aortic surgeon in treating ATAAD.

View Article and Find Full Text PDF

Objectives: To evaluate outcomes after implementation of a preoperative protocol requiring fluoroscopic guidance in patients undergoing thoracoabdominal aortic aneurysm (TAAA) repair identified as being at risk for spinal drain placement complications.

Design: This retrospective analysis included patients who underwent spinal drain placement for TAAA repair between November 2013 and November 2018. Patient outcomes were assessed before (control) and after (study) protocol implementation.

View Article and Find Full Text PDF

Introduction/aim: The partial deployment technique (PDT) is an unconventional option of T-branch deployment to allow target arteries (TAs) cannulation/stenting from the upper arm access, in case of narrow (NPA: <25mm) or severely angulated (APA: >60°) aorta. Aim of this study was to report outcomes of the endovascular repair of complex aortic (c-AAAs) and thoracoabdominal (TAAAs) aneurysms by T-branch and PDT.

Methods: All consecutive patients underwent urgent endovascular repair of c-AAAs and TAAAs by T-branch (Cook-Medical, Bloomington, IN, US) and PDT from 2021 to 2023 were analyzed.

View Article and Find Full Text PDF

: The parallel stent graft endovascular aortic repair (PGEVAR) technique is an off-the-shelf option used for elective complex abdominal aortic aneurysm repair with acceptable outcome results, as reported so far. The PGEVAR technique, using chimney or periscope parallel grafts, can also be used for patients with ruptured complex abdominal aortic aneurysms. However, only few data about the mid- to long-term outcomes are available.

View Article and Find Full Text PDF

Thoracoabdominal aortic aneurysms (TAAAs) are rare but serious conditions characterized by dilation of the aorta characterized by remodeling of the vessel wall, with changes in the elastin and collagen content. Individuals with Marfan syndrome have a genetic predisposition for elastic fiber fragmentation and elastin degradation and are prone to early aneurysm formation and progression. Our objective was to analyze the medial collagen characteristics through histological, polarized light microscopy, and electron microscopy methods across the thoracic and abdominal aorta in twenty-five patients undergoing open surgical repair, including nine with Marfan syndrome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!