A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Renal volume measurements: accuracy and repeatability of US compared with that of MR imaging. | LitMetric

Purpose: To determine the accuracy and repeatability of ultrasonography (US) with the ellipsoid formula in calculating the renal volume.

Materials And Methods: The renal volumes in 20 volunteers aged 19-51 years were determined by using US with the ellipsoid formula and magnetic resonance (MR) imaging with the voxel-count method by two independent observers for each modality. The observers performed all measurements twice, with an interval between the first and second examinations. The voxel-count method was the reference standard. Repeatability was evaluated by calculating the SD of the difference (method of Bland and Altman).

Results: Renal volume was underestimated with US by 45 mL (25%) on average. A comparable underestimation was found when the ellipsoid formula was applied to MR images. This indicates that the inaccuracy of US renal volume measurements (a) occurred because the kidney does not resemble an ellipsoid and (b) was not primarily related to the imaging modality. Intra- and interobserver variations in US volume measurements were poor; the SD of the difference was 21-32 mL. For comparison, the SD of the difference in reference-standard measurements was 5-10 mL.

Conclusion: Use of US with the ellipsoid formula is not appropriate for accurate and reproducible calculation of renal volume.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.211.3.r99jn19623DOI Listing

Publication Analysis

Top Keywords

renal volume
16
ellipsoid formula
16
volume measurements
12
accuracy repeatability
8
voxel-count method
8
renal
6
measurements
5
ellipsoid
5
measurements accuracy
4
repeatability compared
4