The authors developed a temporal subtraction scheme based on a nonlinear geometric warping technique to assist radiologists in the detection of interval changes in chest radiographs obtained on different occasions. The performance of the current temporal subtraction scheme is reasonably good; however, severe misregistration can occur in some cases. The authors evaluated the quality of 100 chest temporal subtraction images selected from their clinical image database. Severe misregistration was mainly attributable to initial incorrect global matching. Therefore, they attempted to improve the quality of the subtraction images by applying a new initial image matching technique to determine the global shift value between the current and the previous chest images. A cross-correlation method was employed for the initial image matching by use of blurred low-resolution chest images. Nineteen cases (40.4%) among 47 poor registered subtraction images were improved. These results show that the new initial image matching technique is very effective for improving the quality of chest temporal subtraction images, which can greatly enhance subtle changes in chest radiographs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3452488PMC
http://dx.doi.org/10.1007/BF03168846DOI Listing

Publication Analysis

Top Keywords

temporal subtraction
20
subtraction images
20
initial image
16
image matching
16
changes chest
12
chest radiographs
12
subtraction
8
detection interval
8
interval changes
8
subtraction scheme
8

Similar Publications

Accessory posterior cerebral artery as a duplicate anterior choroidal artery.

Surg Radiol Anat

January 2025

Department of Neurosurgery, Nakamura Memorial Hospital, South 1, West 14, Chuo-ku, Sapporo, Hokkaido, 060-8570, Japan.

Purpose: Anatomical variations in the anterior choroidal artery (AChA) and/or the posterior cerebral artery (PCA) are rare. Hyperplastic AChA is an anatomical variant supplying both the AChA area and the PCA area. In accessory PCA, a hyperplastic AChA supplies part of the PCA territory.

View Article and Find Full Text PDF

ROBUST OUTER VOLUME SUBTRACTION WITH DEEP LEARNING GHOSTING DETECTION FOR HIGHLY-ACCELERATED REAL-TIME DYNAMIC MRI.

Proc IEEE Int Symp Biomed Imaging

May 2024

Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA.

Real-time dynamic MRI is important for visualizing time-varying processes in several applications, including cardiac imaging, where it enables free-breathing images of the beating heart without ECG gating. However, current real-time MRI techniques commonly face challenges in achieving the required spatio-temporal resolutions due to limited acceleration rates. In this study, we propose a deep learning (DL) technique for improving the estimation of stationary outer-volume signal from shifted time-interleaved undersampling patterns.

View Article and Find Full Text PDF

Background: Superficial temporal artery (STA)-middle cerebral artery (MCA) side-to-side microvascular anastomosis can achieve the same clinical effects as traditional STA-MCA end-to-side anastomosis in extracranial-intracranial revascularization surgery, furthermore, STA-MCA side-to-side anastomosis has the lower risk of postoperative cerebral hyperperfusion syndrome (CHS) and the potential to recruit all scalp arteries as the donor sources via self-regulation. Therefore, STA-MCA side-to-side microvascular anastomosis seems to be a revascularization strategy superior to traditional STA-MCA end-to-side anastomosis. In this study, we presented seven cases in which a STA-MCA side-to-side microvascular anastomosis was performed with a 4-5 mm long arteriotomy using the in-situ intraluminal suturing technique.

View Article and Find Full Text PDF

Traumatic direct type carotid cavernous fistula (CCF) is an acquired arteriovenous shunt between the carotid artery and the cavernous sinus post severe craniofacial trauma or iatrogenic injury. We reported a 46-year-old woman who had developed a traumatic direct type CCF after severe head trauma with a skull base fracture and brain contusion hemorrhage. The clinical manifestations of the patient included pulsatile exophthalmos, proptosis, bruits, chemosis, and a decline in consciousness.

View Article and Find Full Text PDF

Anxiety is a widespread mental health issue, and binaural beats have been explored as a potential non-invasive treatment. EEG data reveal changes in neural oscillation and connectivity linked to anxiety reduction; however, harmonics introduced during signal acquisition and processing often distort these findings. Existing methods struggle to effectively reduce harmonics and capture the fine-grained temporal dynamics of EEG signals, leading to inaccurate feature extraction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!