We present a case of congenital complete heart block associated with maternal autoantibodies in which a normal labor and delivery could safely be allowed to proceed despite the absence of the usual tool of electronic fetal heart rate monitoring for fetal distress, by the technique of rupturing membranes and using a fetal scalp electrode electrocardiographic tracing to assess the fetal atrial rate.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2007-999300DOI Listing

Publication Analysis

Top Keywords

monitoring fetal
8
heart block
8
fetal
5
perinatal monitoring
4
fetal well-being
4
well-being presence
4
presence congenital
4
congenital heart
4
block case
4
case congenital
4

Similar Publications

Background: Pregnancy related hypertension is a leading cause of preventable maternal morbidity and mortality in the US, with consistently higher rates affecting racial minorities. Many complications are preventable with timely treatment, in alignment with the Alliance for Innovation on Maternal Health's Patient Safety Bundle ("Bundle"). The Bundle has been implemented successfully in inpatient settings, but 30% of preeclampsia-related morbidity occurs in outpatient settings in North Carolina.

View Article and Find Full Text PDF

Background: Despite strong evidence-based strategies for prevention and management, global efforts to reduce deaths from postpartum haemorrhage (PPH) have failed, and it remains the leading cause of maternal mortality. We conducted a detailed review of all maternal deaths from 33 facilities in Malawi to identify health system weaknesses leading to deaths from PPH.

Methods: Data were collected regarding every maternal death occurring across all district and central hospitals in Malawi.

View Article and Find Full Text PDF

Evaluating the diagnostic accuracy of fetal scalp blood sampling: A retrospective cohort study.

Eur J Obstet Gynecol Reprod Biol

December 2024

Maternal and Fetal Health Research Centre, Division of Developmental Biology and Medicine, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, UK; Saint Mary's Hospital, Manchester University NHS Foundation Trust, UK.

Introduction: Fetal scalp blood sampling (FSBS) can be used as an adjunctive test, in the presence of a pathological intrapartum fetal heart rate trace, to provide evidence of fetal acidaemia. The role of FSBS remains controversial, this study evaluates the diagnostic accuracy of FSBS at determining various adverse neonatal outcomes.

Method: A retrospective cohort analysis of FSBS undertaken < 1 h from birth in a single UK centre in 2016 and 2017.

View Article and Find Full Text PDF

Perineal deformation during forceps, vacuum and OdonAssist™ assisted vaginal deliveries: A simulation study based on advanced image processing.

Eur J Obstet Gynecol Reprod Biol

January 2025

Department of Obstetrics and Gynecology, Jean Minjoz Hospital, Besançon University Medical Center - Alexander Fleming Boulevard, 25000 Besançon, France; University of Franche-Comte-SINERGIE Laboratory, 25000 Besancon, France. Electronic address:

Objectives: The aim of this study was to analyse influence of the fetal head position and the type of instrument used (forceps, vacuum, OdonAssist™) on perineal deformation, during simulated vaginal deliveries monitored by stereophotogrammetry.

Methods: An exploratory study was conducted using mannequins simulating vaginal births. Fifty simulated deliveries were performed with different fetal head positions and instruments: Pajot's forceps, Kiwi-vacuum, and OdonAssist™.

View Article and Find Full Text PDF

Background: When using electronic health records (EHRs) to conduct population-based studies on inherited bleeding disorders (IBDs), using diagnosis codes alone results in a high number of false positive identifications.

Objective: The objective of this study was to develop and validate an algorithm that uses multiple data elements of EHRs to identify pregnant women with IBDs.

Methods: The population included pregnant women who had at least one live birth or fetal death (>20 weeks gestation) at our institution from 2016 to 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!