Objective: To quantitate the contribution of postprandial blood glucose, which improves with the short-acting insulin analog lispro [Lys(B28),Pro(B29)] in type 1 diabetes, to the overall 24-h blood glucose concentration and the long-term HbA1c concentration under conditions of different postabsorptive blood glucose.

Research Design And Methods: A total of 24 type 1 diabetic patients on long-term intensive therapy with premeal human regular insulin (Hum-R) and bedtime NPH were randomly assigned to a continuation of Hum-R (group 1, n = 8), lispro (group 2, n = 8), or lispro + NPH (in variable proportions) administered at mealtime (group 3, n = 8) for 3 months, NPH administered at bedtime was continued in all three groups. Data from home blood glucose monitoring were collected, and a 24-h plasma glucose and insulin profile was obtained during a 2-day hospital visit to calculate areas under the postprandial glucose curve (3.5 h after breakfast, 3.5 h after lunch, and 3.0 h after dinner for a total of 10.0 h) and the postabsorptive blood glucose curve (the remaining 14.0 h out of 24.0 h) (AUC). Eight nondiabetic subjects were also studied.

Results: The substitution of Hum-R with lispro (group 2) resulted in lower postprandial blood glucose, but greater postabsorptive blood glucose (P < 0.05 vs. group 1). The postprandial blood glucose AUC was lower (161 +/- 19 vs. 167 +/- 20 mg.100 ml-1.h-1), but the postabsorptive blood glucose AUC was greater (155 +/- 22 vs. 142 +/- 19 mg.100 ml-1.h-1) (P < 0.05). Therefore, the 24-h blood glucose AUC was no different (NS). Consequently, HbA1c was no different (NS). This occurred because in group 2, mealtime lispro resulted in normal prandial plasma insulin, but also resulted in lower interprandial concentration (P < 0.05 vs. group 1). When NPH was added to lispro (30% at breakfast, 40% at lunch, 10% at dinner) in group 3, postabsorptive plasma insulin was similar to group 1 (NS), in group 3, the postprandial blood glucose AUC (153 +/- 17 mg.100 ml-1.h-1) was lower and the postabsorptive blood glucose AUC was no different, as compared with group 1 (NS). Therefore, the 24-h blood glucose AUC was lower (147 +/- 17 vs. 155 +/- 21 and 158 +/- 20 mg.100 ml-1.h-1), and HbA1c was lower (6.41 +/- 0.12 vs. 6.84 +/- 0.2 and 6.96 +/- 0.2% (groups 3, 1, and 2 respectively, P < 0.05). Frequency of hypoglycemia was greater in group 2 (P < 0.05), but not in group 3 (NS) vs. group 1.

Download full-text PDF

Source
http://dx.doi.org/10.2337/diacare.22.5.795DOI Listing

Publication Analysis

Top Keywords

blood glucose
52
glucose auc
24
postabsorptive blood
20
postprandial blood
16
+/- mg100
16
mg100 ml-1h-1
16
glucose
15
blood
14
group
14
24-h blood
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!