To produce different amounts of callus in rats, we devised a procedure to fix leg fractures using intramedullary nails that differ in bending rigidity. We inserted a silicone cannula into the intact diaphysis of the tibia of rats that had already been killed and then fractured the tibia by a three-point bending technique. The fracture was stabilised by insertion of either a stainless-steel or polypropylene nail into the silicone cannula. Biomechanical testing showed that the initial stiffness of the fractures differed between the two nail types by a factor of 16. In vivo, 16 Wistar rats were operated on by the same technique to study the formation of callus. Four weeks after fracture, the size of the callus differed significantly between the steel-nailed and polypropylene-nailed fractures. In conclusion, mechanically differing internal fixation devices led to different callus responses in rats when all other factors were kept equal.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jor.1100170215 | DOI Listing |
Can Respir J
October 2024
The Fourth Affiliated Hospital of Soochow University (Suzhou Dushu Lake Hospital), Department of Respiratory and Critical Care Medicine, Suzhou 215000, Jiangsu, China.
To explore the complications of long-term placement of Montgomery T silicone stent (Ttube) in the treatment of subglottic benign airway stenosis (SBAS) and the timing of successful Ttube removal. We retrospectively collected the clinical data of 32 patients with SBAS who underwent the treatment of Ttube and analyzed their placement and successful removal of the Ttube. There were 22 males and 10 females, aged from 21 to 79 years (60.
View Article and Find Full Text PDFPatient Saf Surg
September 2024
Division of Oculofacial and Orbital Surgery, Gavin Herbert Eye Institute, Irvine, CA, USA.
Background: This study aims to evaluate the efficacy of an oxygen scavenging mask device in reducing local oxygen concentrations from nasal cannula ventilation compared to a standard open facial surgical field.
Methods: This is a controlled experiment using a custom-fabricated silicone midfacial oxygen scavenging device, SimMan airway management trainer manikin (Laerdal Medical, Stavanger, Norway), handheld oxygen detector (Forensics Detectors, Los Angeles, United States) and oxygen from a Datex Ohmeda Aisys Carestation anesthesia unit (GE HealthCare, Chicago, United States). Oxygen concentrations were measured at 18 facial landmarks (Fig.
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi
July 2024
Int J Retina Vitreous
June 2024
Department Ophthalmology UZLeuven, Herestraat 49, Leuven, 3000, Belgium.
Background: The EVA Nexus system offers several technical improvements over its predecessor. The newly designed Aveta cannula system for vitrectomy surgery avoids the need for removal of the valve from the infusion cannula. The chamfered leading edge of the cannula also reduces the insertion force needed.
View Article and Find Full Text PDFIndian J Ophthalmol
June 2024
Smt. Kanuri Santhamma Centre for Vitreo-Retinal Diseases, Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India.
Background: Submacular hemorrhage (SMH) is a sight-threatening disorder. Choroidal neovascularization secondary to age-related macular degeneration, polypoidal choroidal vasculopathy, trauma, angioid streaks, and pathological myopia are a few important causes. The conventional treatment of massive SMH is vitrectomy with manual removal of the clot with extensive retinectomy with/without tissue plasminogen activator (tPA).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!