Statement Of Problem: Fracture strength of denture base resins is of great concern, and many approaches have been used to strengthen acrylic resin dentures.
Purpose: This study measured the effect of 5 fiber strengtheners on the fracture resistance of denture base acrylic resin material. Impact strength, transverse strength, deflection, and elasticity modulus values of a heat-polymerized denture base resin (Trevalon), reinforced with glass, carbon, thin Kevlar, thick Kevlar, and polyethylene fibers in woven form were studied.
Material And Methods: One hundred acrylic resin test specimens reinforced with woven fibers were fabricated. The control group consisted of 20 specimens with no fiber reinforcement. For the impact strength test, a Charpy-type impact tester was used. Transverse strength was assessed with a 3-point bending test by using a screw-driven mechanical testing machine. Ten specimens were used for each test.
Results: The highest impact test values were produced by polyethylene-reinforced group, and the lowest values were obtained from specimens containing no fibers. There were significant differences among the test groups, but no significant differences in transverse strength were found. The lowest transverse strength values were obtained for specimens strengthened with polyethylene fibers, which also insignificantly decreased transverse strength of the acrylic resin.
Conclusion: The impact strength of denture base acrylic resins was increased with fibers in woven form. Tested fibers did not have a significant effect on the transverse strengths.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0022-3913(99)70218-0 | DOI Listing |
Medicine (Baltimore)
January 2025
Second Hospital of the Air Force Medical University, Xi 'an, China.
Background: This study investigates the therapeutic efficacy of dynamic neuromuscular stabilization (DNS) technology paired with Kinesio Taping in patients with persistent nonspecific low back pain, as well as the effect on neuromuscular function and pain self-efficacy.
Methods: A randomized controlled clinical study was conducted to collect clinical data on DNS combined with KT for the treatment of chronic nonspecific low back pain from November 2023 to April 2024. The inclusion criteria were patients with chronic nonspecific lower back pain, aged between 18 and 30 years old, and without serious underlying medical conditions, such as cardiac disease, hypertension, and diabetes.
Biomimetics (Basel)
December 2024
Digital Manufacturing and Materials Characterization Laboratory, School of Science and Technology, International Hellenic University, 57001 Thermi, Greece.
The current research aims to analyze the shape and structural features of the eggs of the lepidoptera species sp. (Lepidoptera, Nympalidae) and develop design solutions through the implementation of a novel strategy of biomimetic design. Scanning electron microscopy (SEM) analysis of the chorion reveals a medial zone that forms an arachnoid grid resembling a ribbed dome with convex longitudinal ribs and concave transverse ring members.
View Article and Find Full Text PDFHand Surg Rehabil
January 2025
Unidade do Punho e Mão, Hospital Cuf Tejo, Lisboa, Portugal; Centre Hospitalier Régional Universitaire de Nîmes, Department of Orthopaedic Surgery, Nîmes, France; Orthopaedic Group Ormeau Pyrénées, Polyclinique de L'Ormeau - ELSAN, Tarbes, France.
Compression of the median nerve in the carpal tunnel is a frequent pathology with severe functional impact. An ultrasound-guided technique was developed to preserve structures, diminish scar fibrosis and enable fast return to full activity. Its advantages are safety and low additional cost.
View Article and Find Full Text PDFMult Scler
January 2025
NYU Langone Medical Center, New York, NY, USA.
Background: Neuromyelitis optica spectrum disorder (NMOSD) is a rare autoimmune disorder that occurs in children and adults.
Case: We report a case of a 10-year-old female with AQP4+ NMOSD who presented with paraparesis from longitudinally extensive transverse myelitis (LETM) from C2 to the conus medullaris. The patient showed gradual improvement in strength and sensation with solumedrol and plasma exchange therapy.
Sci Rep
January 2025
Department of Mechanical and Nuclear Engineering, Khalifa University of Science & Technology, Abu Dhabi, UAE.
This study investigates the quasi-static and dynamic compression performance of a newly designed stacked pyramidal lattice (SPL) structure composed of struts that resemble I-beams. These novel lattice structures are 3D-printed considering three different stacking sequences, and their stiffness, strength, and energy absorption properties are experimentally assessed through low-velocity impact (1.54 m/s) and quasi-static compression tests.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!