Purpose: To assess the safety and efficacy of endovascular repair of abdominal aortic aneurysm in high-risk patients during the short to intermediate term.

Materials And Methods: Endovascular aneurysm repair was performed in 50 patients considered too high risk for conventional repair. Stent-grafts were inserted through surgically exposed femoral arteries with fluoroscopic guidance. The anesthetic technique was epidural in 36 patients, general in 12, and local in two. Aortouniiliac stent-grafts were inserted in 42 patients and aortoaortic in eight.

Results: There were no deaths and no conversions to open surgical repair. The primary success rate (complete aneurysm exclusion according to CT criteria) was 88% (44 of 50). The secondary, clinical, and continuing success rates were all 98% (49 of 50). Surgical time was 196 minutes +/- 67 (mean +/- SD), blood loss was 284 mL +/- 386, and volume of contrast material administered was 153 mL +/- 64. The time from the end of the surgery to resumption of a normal diet was 0.58 days +/- 0.56, to ambulation was 1.22 days +/- 0.77, and to discharge from the hospital was 3.63 days +/- 1.60. Wound problems accounted for the majority of complications. There were no instances of pulmonary failure, renal failure, stent-graft migration, or late leakage.

Conclusion: Endovascular repair of abdominal aortic aneurysm is feasible in two-thirds of high-risk patients, with a low mortality and high success rate during the short to intermediate term.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.210.2.r99ja37361DOI Listing

Publication Analysis

Top Keywords

abdominal aortic
12
aortic aneurysm
12
high-risk patients
12
endovascular repair
12
days +/-
12
aneurysm high-risk
8
repair abdominal
8
short intermediate
8
stent-grafts inserted
8
success rate
8

Similar Publications

: To study the influence of diabetes mellitus (DM) and metformin treatment on aneurysm sac remodeling after endovascular aneurysm repair (EVAR). : A retrospective single-center cohort analysis was conducted on consecutive patients who underwent elective EVAR for an infrarenal abdominal aortic aneurysm (AAA) between January 2011 and December 2021. Differences between study groups were analyzed and Kaplan-Meier analysis were employed to describe overall and reintervention-free survival.

View Article and Find Full Text PDF

: The parallel stent graft endovascular aortic repair (PGEVAR) technique is an off-the-shelf option used for elective complex abdominal aortic aneurysm repair with acceptable outcome results, as reported so far. The PGEVAR technique, using chimney or periscope parallel grafts, can also be used for patients with ruptured complex abdominal aortic aneurysms. However, only few data about the mid- to long-term outcomes are available.

View Article and Find Full Text PDF

Endovascular stent graft repair was developed to minimize the invasiveness of open surgery for thoracic and abdominal aortic diseases. This approach involves covering the diseased segment with a stented artificial graft. However, in thoracic endovascular aortic repair (TEVAR) for aortic arch diseases, special consideration is needed to preserve the aortic arch vessels.

View Article and Find Full Text PDF

Thoracoabdominal aortic aneurysms (TAAAs) are rare but serious conditions characterized by dilation of the aorta characterized by remodeling of the vessel wall, with changes in the elastin and collagen content. Individuals with Marfan syndrome have a genetic predisposition for elastic fiber fragmentation and elastin degradation and are prone to early aneurysm formation and progression. Our objective was to analyze the medial collagen characteristics through histological, polarized light microscopy, and electron microscopy methods across the thoracic and abdominal aorta in twenty-five patients undergoing open surgical repair, including nine with Marfan syndrome.

View Article and Find Full Text PDF

: We aimed to predict patient-specific rupture risks and growth behaviors in abdominal aortic aneurysm (AAA) patients using biomechanical evaluation with finite element analysis to establish an additional AAA repair threshold besides diameter and sex. : A total of 1219 patients treated between 2005 and 2024 (conservative and repaired AAAs) were screened for a pseudo-prospective single-center study. A total of 15 ruptured (rAAA) vs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!