Background: Treatment of hypoplasia of the entire arch in coarctation is a surgical challenge. The current approaches have technical difficulties, high recurrence rates, and increased morbidity and mortality.
Methods: Over a 14-month period, a combined extended end-to-end repair with patch enlargement of the concavity of the entire arch was performed in 6 neonates and 1 infant. Through a midsternotomy and using cardiopulmonary bypass and hypothermia, extended end-to-end repair was performed initially leaving the proximal anastomosis open. The enlarging polytetrafluoroethylene patch was then sutured starting at the incised descending aorta distal to the extended end-to-end repair and continued retrogradely through the transverse arch to the ascending aorta proximal to the aortic cannulation site. One neonate had a patent ductus arteriosus and another had ventricular septal defect closure. One neonate had arterial switch and 3 had Norwood-type procedures performed with the enlarging patch extended to the pulmonary artery anastomosis. The remaining infant had arch enlargement performed after an arterial switch procedure and extended end-to-end repair.
Results: All patients did well and showed no residual gradient up to 1 year follow-up. Two patients successfully had bidirectional Glenn shunt at 9 months of age, and one had closure of residual arterial septal defect at 8 months of age.
Conclusion: The combined extended end-to-end repair and arch enlargement procedure should minimize recurrence rates because of a tension-free enlargement of the entire aortic arch and elimination of the coarctation ridge and ductile tissues. Combined with the arterial switch and Norwood-type procedures, the approach results in a large neoaorta.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0003-4975(98)01254-5 | DOI Listing |
Kardiochir Torakochirurgia Pol
December 2024
Tashkent Pediatric Medical Institute Hospital, Tashkent, Uzbekistan.
Introduction: Coarctation of the aorta (CoA) patients often experience recoarctation, the reoccurrence of aortic narrowing, presenting a considerable clinical challenge.
Aim: This study aims to investigate the triggers or contributing factors associated with the development of recoarctation (reCoA) following the initial repair of CoA.
Material And Methods: The retrospective cohort study includes information about 120 patients, who underwent 4 different types of surgical repairs of coarctation of the aorta through left thoracotomy in the period 2012-2022.
JTCVS Open
December 2024
Department of Cardiac Surgery, Boston Children's Hospital, Boston, Mass.
Objective: For neonatal repair of coarctation of the aorta, patients may either undergo thoracotomy with extended end-to-end anastomosis or sternotomy for aortic arch reconstruction with cardiopulmonary bypass. The objective of this study was to evaluate the comparative effectiveness of the 2 approaches in patients with arch hypoplasia.
Methods: This is a single-center retrospective cohort study from July 2005 through May 2022 of patients who underwent neonatal repair for isolated coarctation of the aorta with additional arch hypoplasia.
Sci Rep
January 2025
Department of Electronics and Communication Engineering, Nagarjuna College of Engineering and Technology, Bengaluru, 562164, Karnataka, India.
Wireless sensor networks (WSNs) are imperative to a huge range of packages, along with environmental monitoring, healthcare structures, army surveillance, and smart infrastructure, however they're faced with numerous demanding situations that impede their functionality, including confined strength sources, routing inefficiencies, security vulnerabilities, excessive latency, and the important requirement to keep Quality of Service (QoS). Conventional strategies generally goal particular troubles, like strength optimization or improving QoS, frequently failing to provide a holistic answer that effectively balances more than one crucial elements concurrently. To deal with those challenges, we advocate a novel routing framework that is both steady and power-efficient, leveraging an Improved Type-2 Fuzzy Logic System (IT2FLS) optimized by means of the Reptile Search Algorithm (RSA).
View Article and Find Full Text PDFStructure
December 2024
Key Laboratory of Biomacromolecules (CAS), National Laboratory of Biomacromolecules, CAS Center for Excellence in Biomacromolecules, Institute of Biophysics, Chinese Academy of Sciences, 15 Datun Road, Beijing 100101, China; College of Life Sciences, University of Chinese Academy of Sciences, Beijing 100049, China. Electronic address:
BORC (BLOC-one-related complex) is a hetero-octameric complex, consisting of eight coiled-coil proteins (BORCS1-8). BORC controls lysosomal and synaptic vesicle transport and positioning by recruiting ARL8. The structural mechanisms underlying BORC assembly and ARL8 activation remain unclear.
View Article and Find Full Text PDFMed Image Anal
December 2024
School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, China; Shanghai United Imaging Intelligence Co., Ltd., Shanghai, China; Shanghai Clinical Research and Trial Center, Shanghai, China. Electronic address:
Variations in hue and contrast are common in H&E-stained pathology images due to differences in slide preparation across various institutions. Such stain variations, while not affecting pathologists much in diagnosing the biopsy, pose significant challenges for computer-assisted diagnostic systems, leading to potential underdiagnosis or misdiagnosis, especially when stain differentiation introduces substantial heterogeneity across datasets from different sources. Traditional stain normalization methods, aimed at mitigating these issues, often require labor-intensive selection of appropriate templates, limiting their practicality and automation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!