Unlabelled: One of the most serious complications of conventional endotracheal intubation is unidentified placement of the tube in the esophagus. The aim of our study was to evaluate four different methods for immediate detection of the tube position: auscultation, capnographic determination of ETCO2, esophageal detection method (EDM) using a self-inflating bulb, and the transillumination method using a lighted stylet (Trachlight; Laerdal, Armonk, NY). Thirty-eight endotracheally intubated patients admitted to our medical intensive care unit were enrolled in the study. A second identical tube was inserted into the esophagus under laryngoscopic control. The endotracheal tube was then disconnected from the ventilator. Two blinded examiners, one experienced, the other inexperienced, determined the tube position within 30 s using one of the four methods. The order of the tubes tested and the methods used were randomized. In 130 of 152 examinations, both examiners correctly diagnosed the position of the tube. The wrong result was obtained by both examiners 4 times; only the experienced examiner was wrong 4 times, and only the inexperienced examiner was wrong 14 times. Using ETCO2, both examiners were correct in all cases. Auscultation showed an obvious relation to the examiner's experience: the experienced examiner was correct in all cases, the inexperienced examiner was correct in only 68% of cases. Using the self-inflating bulb, there were two wrong results of the experienced examiner and one wrong result of the inexperienced examiner. The transillumination technique was associated with a high error rate by both examiners (16% and 13%, respectively). Comparing all four methods showed that capnography is superior to auscultation (P = 0.0005) and to the Trachlight detection method (P = 0.0078). EDM was not statistically superior to auscultation and transillumination. Capnography was the most reliable method for rapid evaluation of tube position, followed by EDM, whereas auscultation and Trachlight did not seem to be of comparable value. Experience was a determining factor for auscultation.
Implications: To prevent unidentified esophageal intubation, a serious complication in the critical care setting, four methods for detecting tube position were tested by two examiners (one experienced, the other inexperienced) in endotracheally intubated patients after insertion of a second tube into the esophagus.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00000539-199904000-00016 | DOI Listing |
J Clin Nurs
January 2025
Shanghai East Hospital, School of Medicine, Tongji University, Shanghai, China.
Aims And Objectives: This study aimed to investigate the impact of sleep position preferences (SPP) on sleep quality, comfort and catheter care quality in patients after endoscopic nasobiliary drainage (ENBD).
Design: This was an observational prospective study.
Methods: This study included 167 participants with common bile duct stones (CBDS) who underwent ENBD from the gallstone ward of a hospital as a convenience sample.
Materials (Basel)
January 2025
Department of Periodontology, Dental Research Division, Guarulhos University, Guarulhos 07023-070, Brazil.
Objective: The objective of this study was to evaluate autologous platelet-rich fibrin (PRF) membrane weights and measurements after production by different centrifuges. Moreover, the values obtained with blood cellular components were correlated.
Methods: Twelve systemically healthy participants underwent dental implant surgery associated with PRF membranes as the graft biomaterial at the implant site.
Int J Mol Sci
January 2025
Department of Developmental and Regenerative Biology, Medical Research Institute, Institute of Science Tokyo, Tokyo 113-8510, Japan.
The eye primordium of vertebrates initially forms exactly at the side of the head. Later, the eyeball architecture is tuned to see ahead with better visual acuity, but its molecular basis is unknown. The position of both eyes in the face alters in patients with holoprosencephaly due to () mutations that disturb the development of the ventral midline of the neural tube.
View Article and Find Full Text PDFPLOS Glob Public Health
January 2025
Médecins Sans Frontières, International, Geneva, Switzerland.
Ultraportable (UP) X-ray devices are ideal to use in community-based settings, particularly for chest X-ray (CXR) screening of tuberculosis (TB). Unfortunately, there is insufficient guidance on the radiation safety of these devices. This study aims to determine the radiation dose by UP X-ray devices to both the public and radiographers compared to international dose limits.
View Article and Find Full Text PDFAnn Card Anaesth
January 2025
Department of Anaesthesiology, Lilavati Hospital and Research Centre, Mumbai, Maharashtra, India.
We report a case of a 74-year-old female with a retrosternal goiter undergoing video-assisted thoracic surgery (VATS) for a left lung lower lobectomy, necessitating one-lung ventilation (OLV). We encountered a highly unusual complication: contralateral tension pneumothorax. Forty-five minutes into the surgical procedure, a sudden cardiovascular collapse occurred.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!