The objective was to study results of carotid endarterectomies performed between 1975 and 1991, comparing primary closure to Dacron patch closure. This was a retrospective study. Data from patient follow-up by physical examination, chart review, and Duplex study were used. Scan data were obtained in 92 of the primary cases, at a mean of 5 years postoperatively, and in 63 of the patch cases, at a mean of 4.1 years postoperatively. During this period, 269 endarterectomies were closed primarily and 101 were closed with a knitted Dacron patch. Twenty patients in the primary group and nine patients with patch closure were lost to follow-up, which extended for up to 12.5 years, with a mean of 4.7 +/- 3.6 years. No acute closures, infections or aneurysms developed in either group. Perioperative stroke incidence was 4.1 per cent for primary closure and 3.0 per cent for the patch group (P > 0.05). Late stenosis occurred in 17.3 per cent of the primary group and 11.1 per cent of the patch closure group (P > 0.05). Five-year survival was 76.2 per cent in the primary group, compared with 79.2 per cent for patch closure. Late stroke incidence was 2.8 per cent in the primary group and 3.3 per cent in the patch closure group. Results of smaller (< or = 3.5 mm) carotid arteries closed with knitted Dacron patches are equivalent to those of larger carotid arteries closed primarily.
Download full-text PDF |
Source |
---|
J Neurosurg Pediatr
January 2025
2Norton Children's Hospital and Norton Children's Neuroscience Institute, Norton Healthcare, Louisville; and.
Objective: CSF leaks are a significant source of patient morbidity following intradural spine surgeries. Watertight dural closure is crucial during these procedures to minimize the risk of a CSF leak. This study reports postoperative outcomes and changes in patient management after switching to penetrating titanium clips for dural closure in a large cohort of pediatric patients receiving a tethered cord release (TCR) or a selective dorsal rhizotomy (SDR).
View Article and Find Full Text PDFJ Innov Card Rhythm Manag
December 2024
University of Arizona College of Medicine-Phoenix, Phoenix, AZ, USA.
Device infection remains a dreaded and increasingly common complication of pacemaker procedures, often mandating removal of all implanted materials. Intensive wound management may be necessary following extraction, requiring multiple follow-up encounters in the outpatient setting. Here, a case of pacemaker pocket infection necessitating complete system extraction is presented.
View Article and Find Full Text PDFJ Clin Med
December 2024
Division of Plastic, Aesthetic and Reconstructive Surgery, Department of Surgery, Medical University of Graz, 8036 Graz, Austria.
Non-healing soft tissue defects pose challenges to treating physicians. Microsurgical reconstruction is a treatment option for achieving wound closure and limb salvage. These free tissue transfers are often challenging due to associated risk factors.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan.
The Y-incision aortic annular enlargement (AAE) has been established as a safe and effective technique for upsizing the aortic annulus by 3 to 4 valve sizes. However, concerns have been raised regarding its technical complexity during reoperations, particularly given the extensive enlargement of the aortic annulus and root. We present a case of reoperative aortic valve replacement after previous Y-incision AAE for prosthetic valve endocarditis and aortic root abscess.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
September 2024
Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan.
A 54-year-old man underwent right S6 segmentectomy for right lung cancer. After discharge, he presented with fever, hemoptysis, and cough, and computed tomography showed an intermediate bronchus fistula. Because direct closure or bronchoplasty was challenging, a Dumon (Novatech) stent was inserted directly into the fistula from the surgical field and covered with an autologous pericardial patch, pedicled mediastinal fat, and intercostal muscle.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!