Objective: To compare the overall diagnostic costs associated with non-contrast and contrast echocardiography.

Study Design: Phase III clinical trial.

Patients And Methods: In a secondary analysis of data from a phase III clinical trial of the intravenous contrast agent Optison, we compared the costs associated with obtaining a diagnosis in 203 patients who underwent non-contrast and contrast echocardiography. Costs for the initial test and any follow-up tests were derived from adjusted Medicare charges and a transition-1 microcost accounting system.

Results: Diagnostic yield from echocardiograms was 87% with the use of Optison (3 mL) and 49% when no contrast agent was used (P < 0.001). Because technically inadequate echocardiograms were more common in the non-contrast group, follow-up testing was recommended for 42% of patients in this group compared with 12% of those who had undergone a contrast-enhanced echocardiogram (P < 0.001). Although use of Optison increased the initial diagnostic cost by $125, overall costs were 17% lower when Optison was used (P < 0.0001). Use of Optison also resulted in a 17% to 70% decrease in confirmatory transesophageal echocardiography, catheterization, and nuclear studies. Optison improved diagnostic accuracy by 2.7-fold in patients with an initial non-diagnostic echocardiogram, resulting in a substantial cost savings of $269 per patient.

Download full-text PDF

Source

Publication Analysis

Top Keywords

contrast agent
12
intravenous contrast
8
optison
8
agent optison
8
costs associated
8
non-contrast contrast
8
phase iii
8
iii clinical
8
optison enhance
4
enhance echocardiography
4

Similar Publications

Background: The skin, with its robust structural integrity and advanced immune defense system, serves as a critical protective barrier against environmental toxins and carcinogenic compounds. Despite this, it remains vulnerable to the harmful effects of certain hazardous agents.

Objectives: This study aimed to investigate the chemopreventive potential of β-caryophyllene (BCP) in mitigating 7,12-dimethylbenz[a]anthracene (DMBA)-induced skin carcinogenesis, focusing on the modulation of apoptosis and PI3K/AKT signaling pathways.

View Article and Find Full Text PDF

Aims: To develop a transformer-based generative adversarial network (trans-GAN) that can generate synthetic material decomposition images from single-energy CT (SECT) for real-time detection of intracranial hemorrhage (ICH) after endovascular thrombectomy.

Materials: We retrospectively collected data from two hospitals, consisting of 237 dual-energy CT (DECT) scans, including matched iodine overlay maps, virtual noncontrast, and simulated SECT images. These scans were randomly divided into a training set (n = 190) and an internal validation set (n = 47) in a 4:1 ratio based on the proportion of ICH.

View Article and Find Full Text PDF

Under conditions that are close to the real cellular environment, the human telomeric single-stranded overhang (∼200 nt) consisting of tens of TTAGGG repeats tends to form higher order structures of multiple G-quadruplex (G4) blocks. On account of the higher biological relevance of higher order G4 structures, ligand compounds binding to higher order G4 are significant for the drug design toward inhibiting telomerase activity. Here, we study the interaction between a cationic porphyrin derivative, 5,10,15,20-tetra{4-[2-(1-methyl-1-piperidinyl)propoxy]phenyl}porphyrin (T4), and a human telomeric G4-dimer (AG(TAG)) in the mimic intracellular molecularly crowded environment (PEG as a crowding agent) and K or Na solution (i.

View Article and Find Full Text PDF

Objectives: To evaluate the effectiveness of breast MRI, including diffusion-weighted imaging (DWI), in detecting residual lesions in patients with malignancy after excisional biopsy.

Methods: From January 2018 to December 2023, 3T breast MRI was performed to assess lesion morphology, residual size, and enhancement kinetics. The apparent diffusion coefficient (ADC) values were measured, and the diagnostic outcomes of CE-MRI, CE-MRI with DWI, mammography (MG), and ultrasound (US) were compared with clinical and histopathological data.

View Article and Find Full Text PDF

Objectives: Accurate kidney and tumor segmentation of computed tomography (CT) scans is vital for diagnosis and treatment, but manual methods are time-consuming and inconsistent, highlighting the value of AI automation. This study develops a fully automated AI model using vision transformers (ViTs) and convolutional neural networks (CNNs) to detect and segment kidneys and kidney tumors in Contrast-Enhanced (CECT) scans, with a focus on improving sensitivity for small, indistinct tumors.

Methods: The segmentation framework employs a ViT-based model for the kidney organ, followed by a 3D UNet model with enhanced connections and attention mechanisms for tumor detection and segmentation.

View Article and Find Full Text PDF