The mechanical properties of biodegradable polymers and composites proposed for use in internal fixation (in place of stainless steel) are crucial to the performance of devices made from them for support of healing bone. To assess the reported range of properties and degradation rates, we searched and reviewed papers and abstracts published in English from 1980 through 1988. Mechanical property data were found for poly(lactic acid), poly(glycolic acid), poly(epsilon-caprolactone), polydioxanone, poly(ortho ester), poly(ethylene oxide), and/or their copolymers. Reports of composites based on several of these materials, reinforced with nondegradable and degradable fibers, were also found. The largest group of studies involved poly(lactic acid). Mechanical test methods varied widely, and studies of the degradation of mechanical properties were performed under a variety of conditions, mostly in vitro rather than in vivo. Compared to annealed stainless steel, unreinforced biodegradable polymers were initially up to 36% as strong in tension and 54% in bending, but only about 3% as stiff in either test mode. With fiber reinforcement, reported highest initial strengths exceeded that of stainless steel. Stiffness reached 62% of stainless steel with nondegradable carbon fibers, 15% with degradable inorganic fibers, but only 5% with degradable polymeric fibers. The slowest-degrading unreinforced biodegradable polymers were poly(L-lactic acid) and poly(ortho ester). Biodegradable composites with carbon or inorganic fibers generally lost strength rapidly, with a slower loss of stiffness, suggesting the difficulty of fiber-matrix coupling in these systems. The strength of composites reinforced with (lower modulus) degradable polymeric fibers decreased more slowly. Low implant stiffness might be expected to allow too much bone motion for satisfactory healing. However, unreinforced or degradable polymeric fiber reinforced materials have been used successfully clinically. The key has been careful selection of applications, plus use of designs and fixation methods distinctly different from those appropriate for stainless steel devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jab.770010109 | DOI Listing |
ChemSusChem
January 2025
Universita degli study di cagliari, Dipartimento di Scienze Chimiche e Geologiche, Cittadella Universitaria, SS 554 bivio per Sestu, 09042, Monserrato, ITALY.
Solvent-free techniques have gained considerable attention in recent years due to their environmental advantages and potential to enable chemical reactivities beyond the reach of traditional solution-based methods. Mechanochemistry has emerged as a groundbreaking approach to drive sustainable chemical processes. Despite its promise, some challenges still need to be explored, including the overlooked issue of material leaching during grinding, a phenomenon in which components from milling media or reaction vessels, such as stainless steel, unintentionally alter reaction outcomes.
View Article and Find Full Text PDFInt J Low Extrem Wounds
January 2025
Laser Physics Department, College of Science for Women, University of Babylon, Hillah, Iraq.
The utilization of zinc oxide nanoparticles is thought to augment wound healing because of their antibacterial characteristics and capacity to stimulate cellular regeneration, especially in instances of minor burn injuries. On the other hand, it has been shown that tissue regeneration is aided by low-power laser therapy via photobiomodulation. Zinc oxide nanoparticles and low-power laser therapy are the two therapeutic modalities that will be compared in this study in order to assess how well they promote healing after burn injury and provide important new information on improved wound care techniques.
View Article and Find Full Text PDFRSC Adv
January 2025
Norwegian Tribology Center, Department of Mechanical and Industrial Engineering, Norwegian University of Science and Technology (NTNU) Trondheim Norway
The focus on energy efficiency to move towards a more sustainable use of resources has intensified efforts to minimize friction and wear in mechanical systems, which account for 23% of the world's energy consumption. In this study, polyoxometalate ionic liquids (POM-ILs) are introduced as environmentally acceptable lubricant additives, for their potential friction-reducing and anti-wear (AW) properties. These compounds, characterized by their complex structures and tunable properties, have been investigated for their tribological performance across base fluids of varying polarities.
View Article and Find Full Text PDFAdv Healthc Mater
January 2025
Laboratory for Biointerfaces, Empa, Swiss Federal Laboratories for Materials and Technology, Lerchenfeldstrasse 5, St. Gallen, 9014, Switzerland.
Surface-mediated transmission of pathogens plays a key role in healthcare-associated infections. However, proper techniques for its quantitative analysis are lacking, making it challenging to develop novel antimicrobial and anti-fouling surfaces to reduce pathogen spread via environmental surfaces. This study demonstrates a gelatin hydrogel-based touch transfer test, the HydroTouch test, to evaluate pathogen transmission on high-touch surfaces under semi-dry conditions.
View Article and Find Full Text PDFSci Rep
January 2025
Faculty of Mechanical Engineering, VŠB -Technical University of Ostrava, 17. listopadu 2172/15, 708 00, Ostrava-Poruba, Czech Republic.
Three types of commercial austenitic stainless steels, 1.4307 (AISI 304 L), 1.4404 (AISI 316 L) 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!