Seven PCA infusion pumps from seven manufacturers were evaluated. The condition for acceptable use of most of the units is that they not be used at low volumes that could result in overinfusion from the stored volume when an occlusion is cleared. All pumps met most accuracy, electrical safety, and performance criteria. Purchasing decisions should also take into consideration the cost of disposables, application, and medication security.

Download full-text PDF

Source

Publication Analysis

Top Keywords

infusion pumps
8
evaluation selection
4
selection patient-controlled
4
patient-controlled analgesia
4
analgesia infusion
4
pumps pca
4
pca infusion
4
pumps manufacturers
4
manufacturers evaluated
4
evaluated condition
4

Similar Publications

Background: A growing number of centers offer hepatic artery infusion pump (HAIP) chemotherapy for advanced liver malignancies. While small series have demonstrated feasibility of robotic HAIP placement, comparison of outcomes with open placement is lacking. We compared outcomes after robotic versus open HAIP placement.

View Article and Find Full Text PDF

A woman in her 40s presented with severe post-bariatric hypoglycaemia that persisted despite nutritional therapy and pharmacological therapy with acarbose and subcutaneous octreotide with meals. The nutritional limitations were difficult to sustain, and she developed adverse effects to the pharmacological therapy, and hence, doses could not be increased. She was subsequently treated with subcutaneous octreotide via an insulin pump, with a continuous basal rate and additional bolus doses with meals.

View Article and Find Full Text PDF

Patients with type 1 diabetes and their physicians have long desired a fully closed-loop artificial pancreas (AP) system that can alleviate the burden of blood glucose regulation. Although deep reinforcement learning (DRL) methods theoretically enable adaptive insulin dosing control, they face numerous challenges, including safety and training efficiency, which have hindered their clinical application. This paper proposes a safe and efficient adaptive insulin delivery controller based on DRL.

View Article and Find Full Text PDF

Refractory cancer pain affects 10-20% of patients with advanced malignancies and is not adequately controlled by opioids. The intrathecal therapy is an effective interventional procedure for referral, but the implanted infusion pumps are costly and the refilling requires technical expertise. Hypophysectomy, in its three stages-surgical, chemical, and radiosurgical-has emerged as an alternative for managing this pain.

View Article and Find Full Text PDF

Introduction: With the increasing use of aeromedical transport for critically ill patients, it is essential to understand the impact of pressure changes on drug infusion delivery systems. As airplanes ascend and descend, gases/bubbles are released from solutions when ambient pressure decreases and dissolves when pressure increases. This may affect mechanical fluid delivery systems and cause clinically significant changes, especially within a critical care setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!