Transcatheter intracavitary fibrinolysis of loculated pleural effusions: experience in 102 patients.

Cardiovasc Intervent Radiol

Interventional Radiology Service, Hospital Clínico Universitario, C/ San Juan Bosco 15, E-50009 Zaragoza, Spain.

Published: July 1999

Purpose: To assess the efficacy of intrapleural urokinase instillation through small-caliber catheters for the treatment of loculate and/or septate effusions.

Methods: We inserted small-caliber catheters (8.2 Fr) in 102 patients with septate and/or loculate pleural effusions using ultrasonographic guidance. Urokinase (100,000 IU/2 hr, 3 times a day) was instilled through the catheter until the effusion resolved and D-dimer levels were <500 ng/ml. Patients were enrolled regardless of the etiology of the pleural effusion provided there were no contraindications for the use of urokinase. D-dimer levels were determined before and after treatment. Follow-up was performed by chest radiograph and sonography at 1 day, 7 days, and every 30 days thereafter for 6 months.

Results: Successful catheter placement was achieved in all cases. The mean time catheters stayed in place was 5.7 days and the mean dose of drug instilled was 690,000 IU. Pleural effusion drainage was complete at the first assessment in all patients. Failure of the treatment, with recurrent effusion at 30 days, occurred in six patients (5.8%). Complete resolution without sequelae was observed in 19 patients (19.6%). In 75 cases (73.5%) resolution was partial, with pleural thickening (>2 mm). Two patients died from unrelated causes within 30 days after catheter placement. Complications were seen in 13 patients (12.74%): hydropneumothorax, nine cases (8.82%); infection of the puncture point, three cases (2.94%); and adverse reaction, one case (0.98%). No further treatment was required.

Conclusion: The use of intrapleural fibrinolytic agents delivered through small-caliber catheters for the treatment of loculate and/or septate pleural effusion is a simple, effective, minimally invasive and inexpensive procedure that can prevent sequelae and shorten drainage time.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s002709900345DOI Listing

Publication Analysis

Top Keywords

small-caliber catheters
12
pleural effusions
8
102 patients
8
catheters treatment
8
treatment loculate
8
loculate and/or
8
and/or septate
8
transcatheter intracavitary
4
intracavitary fibrinolysis
4
fibrinolysis loculated
4

Similar Publications

Article Synopsis
  • - The text discusses the difficulties faced in closing coronary fistulas due to the complex shape and small size of the abnormal blood vessels.
  • - It introduces microvascular plugs (MVP), which are specialized devices designed for blocking off small blood vessels, and highlights their advantages like being easier to use with smaller catheters.
  • - The article presents three adult cases where coronary fistulas were successfully closed using these MVPs through a radial access approach.
View Article and Find Full Text PDF

Enhancing Guidewire Efficacy for Transradial Access: The EAGER Randomized Controlled Trial.

Circ Cardiovasc Interv

October 2024

Cardiology Department, Gosford Hospital, Central Coast Local Health District, Australia (A.C.B., W.M., P.M., E.C., E.R., N.H., A.P., S.L.S., A.K., T.K., A.H., R.S., K.S., A.M., M.P., M.I., M.W., P.J., T.J.F.).

Background: The 1.5 mm Baby J hydrophilic narrow J-tipped wire is a development of the standard 0.035" 3-mm J-tipped peripheral guidewire, designed to improve efficiency of transradial coronary procedures by safely navigating small caliber radial arteries to the aorta.

View Article and Find Full Text PDF

The conus artery (CA) supplies the right ventricular outflow tract (RVOT). ST-segment elevation in leads V1-3, which can resemble Brugada electrocardiogram (EKG) patterns, has been reported due to occlusion of the CA. A 68-year-old male was admitted to the hospital with a diagnosis of non-ST-elevation myocardial infarction.

View Article and Find Full Text PDF

Percutaneous endovascular treatment of peripheral vascular disease with small-caliber short sheaths may lead to device removal difficulties. A 50-year-old woman on hemodialysis underwent endovascular intervention for right common femoral artery stenosis, via the right brachial artery. A 4-Fr short sheath was used for the procedure owing to a previous hematoma at the puncture site.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!