Usefulness of transthoracic echocardiography in detecting significant prosthetic mitral valve regurgitation.

Am J Cardiol

Department of Medicine, Baylor College of Medicine, The Methodist Hospital, Houston, Texas 77030, USA.

Published: January 1999

To identify the transthoracic echo-Doppler (TTE) variables most predictive of significant mitral regurgitation (MR) of mechanical prosthetic valves, TTE and trans-esophageal echo (TEE) studies were independently reviewed in 57 patients (mean age [+/-SD] 59+/-12.5 years) undergoing both studies within 2+/-3 days. Several 2-dimensional and Doppler hemodynamic variables from the TTE studies were derived. Prosthetic MR was significant (moderate or severe) by TEE in 20 patients, whereas mild or no MR was seen in 37 patients. The best univariate predictors of significant MR by TTE were peak velocity of mitral inflow, mean gradient, tricuspid regurgitation velocity, isovolumic relaxation time, and ratio of time velocity integral of mitral inflow to time velocity integral in the left ventricular outflow (TVI(MV)/TVI(LVO)). Peak mitral velocity and TVI(MV)/TVI(LVO) were the best predictors of significant MR and performed similarly (area under the receiver-operating characteristic curve: 0.97 for both). A peak velocity of > or =1.9 m/s was 90% sensitive and 89% specific for significant prosthetic MR, whereas a TVI(MV)/TVI(LVO) > or =2.5 had a sensitivity and specificity of 89% and 91%, respectively. A decision tree was constructed to assess the conditional probabilities of having significant MR given all the possible outcomes of the 2 best predictors. None of the patients with peak velocity < 1.9 m/s and TVI(MV)/TVI(LVO) <2.5 by TTE had significant MR. Conversely, all patients with peak velocity > or =1.9 m/s and TVI(MV)/TVI(LVO) > or =2.5 had significant MR. The use of more complex algorithms did not further improve the results. Thus, measurements of hemodynamic Doppler variables on TTE examination can accurately identify a large number of patients without significant prosthetic MR, thereby reducing the need for further investigation with TEE.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0002-9149(98)00824-8DOI Listing

Publication Analysis

Top Keywords

peak velocity
12
variables tte
8
mitral inflow
8
time velocity
8
velocity integral
8
best predictors
8
=19 m/s
8
tvimv/tvilvo =25
8
m/s tvimv/tvilvo
8
velocity
7

Similar Publications

Intraluminal prosthetic graft thrombus (IPT) has been described in case of endovascular aortic pathology repair. This study aimed to assess hemodynamic indicators associated with various anatomical morphologies following endovascular aortic repair (EVAR), aiming to offer further references for the choice of clinical therapy. Six model models (normal, iliac compression, aortic compression, aortoiliac compression, iliac distortion, and long-leg stent) were established based on common anatomical morphologies following EVAR.

View Article and Find Full Text PDF

Previous studies demonstrated that dexmedetomidine (Dex) posttreatment aggravated myocardial dysfunction and reduced survival in septic mice. Yet, whether Dex elicits similar effects in septic patients as defined by Sepsis-3 remains unknown. This study sought to assess the effects of Dex-based sedation on mortality and cardiac dysfunction in septic patients defined by Sepsis-3 and to further reveal the mechanisms in septic rats.

View Article and Find Full Text PDF

Assessment of varus thrust using inertial measurement units.

Clin Biomech (Bristol)

December 2024

Department of Kinesiology and Applied Physiology, University of Delaware, Newark, DE, USA. Electronic address:

Background: Varus thrust is common in those with knee osteoarthritis. Varus thrust is traditionally identified with visual analysis or motion capture, methods that are either dichotomous or limited to the laboratory setting. Inertial measurement unit data has been found to correlate with motion capture measures of varus thrust in those with severe knee osteoarthritis, allowing for a quantitative and accessible way of measuring varus thrust.

View Article and Find Full Text PDF

Blasting excavation is widely used in mining, tunneling and construction industries, but it leads to produce ground vibration which can seriously damage the urban communities. The peak particle velocity (PPV) is one of main indicators for determining the extent of ground vibration. Owing to the complexity of blasting process, there is controversy over which parameters will be considered as the inputs for empirical equations and machine learning (ML) algorithms.

View Article and Find Full Text PDF

The continuous exposure of chemical pesticides in agriculture, their contamination in soil and water pose serious threat to the environment. Current study used an approach to evaluate various pesticides like Hexaconazole, Mancozeb, Pretilachlor, Organophosphate and λ-cyhalothrin degradation capability of esterase. The enzyme was isolated from Salinicoccus roseus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!