We report for the first time that cultured lens epithelial cell layers and rabbit lenses in vitro transport fluid. Layers of the alphaTN4 mouse cell line and bovine cell cultures were grown to confluence on permeable membrane inserts. Fluid movement across cultured layers and excised rabbit lenses was determined by volume clamp (37 degrees C). Cultured layers transported fluid from their basal to their apical sides against a pressure head of 3 cmH2O. Rates were (in microliter. h-1. cm-2) 3.3 +/- 0.3 for alphaTN4 cells (n = 27) and 4.7 +/- 1.0 for bovine layers (n = 6). Quinidine, a blocker of K+ channels, and p-chloromercuribenzenesulfonate and HgCl2, inhibitors of aquaporins, inhibited fluid transport. Rabbit lenses transported fluid from their anterior to their posterior sides against a 2.5-cmH2O pressure head at 10.3 +/- 0.62 microliter. h-1. lens-1 (n = 5) and along the same pressure head at 12.5 +/- 1.1 microliter. h-1. lens-1 (n = 6). We calculate that this flow could wash the lens extracellular space by convection about once every 2 h and therefore might contribute to lens homeostasis and transparency.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/ajpcell.1999.276.3.C548 | DOI Listing |
PLoS One
January 2025
Laboratory and Forensic Medicine (I-PPerForM), Institute of Pathology, Universiti Teknologi MARA, Sungai Buloh, Selangor, Malaysia.
Cataracts are significant causes of blindness, closely linked to prolonged hypercholesterolemia. While saffron has the potential for eye health, its effects on lens lesions remain understudied. This study aimed to investigate the effect of saffron on the lens changes in atherosclerotic-induced New Zealand white rabbits (NZWR).
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Fudan University Eye Ear Nose and Throat Hospital, Shanghai, China.
Background: To evaluate the biosafety, reduction in anterior capsule opacification, and fluctuation in intraocular pressure (IOP) of a new phakic refractive lens (PRL) with a sinusoidal drainage groove design.
Methods: This self-controlled experiment was performed on eight eyes of four rabbits. Each rabbit was implanted with a sinusoidal PRL (PRL-S5) in the right eye and a conventional posterior chamber PRL (PC-PRL) in the left eye.
Acta Biomater
January 2025
National Engineering Research Center of Ophthalmology and Optometry, School of Biomedical Engineering, School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, China. Electronic address:
Posterior capsule opacification (PCO) is the most common complication after cataract surgery. It is primarily caused by the proliferation, migration, and adhesion of residual lens epithelial cells within the capsular bag following phacoemulsification and intraocular lens (IOL) implantation. Although investigations of surface modification onto IOL have partially reduced PCO development in recent years, there are still challenges in long-term efficacy and intraocular biocompatibility.
View Article and Find Full Text PDFColloids Surf B Biointerfaces
January 2025
National Engineering Research Center of Ophthalmology and Optometry, School of Biomedical Engineering, School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, China. Electronic address:
Intraocular lens (IOL) implantation surgery is the most effective treatment for cataract. However, glistening formed by the incoming liquid microvacuoles can significantly damage postoperative visual quality after prolonged implantation, for which there is still lack of effective clinical treatment. In this study, inspired by the amazing water-repellency of natural superhydrophobic surface, a functionalized IOL material modified with the superhydrophobic and transparent coating was prepared using layer-by-layer electrostatic self-assembly technique combined with fluorination.
View Article and Find Full Text PDFJ Control Release
December 2024
School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, Zhejiang, China. Electronic address:
Bacterial keratitis is a major cause of blindness, hindered by the rising threat of antibiotic resistance. Although corneal bandage lenses (CBLs) are widely utilized in ophthalmic treatment, their effectiveness in treating bacterial keratitis remains limited due to risks of secondary infections, patient discomfort, and complications. In this study, we developed a novel biomimetic coating on CBLs by grafting Ag/Cu bimetallic nanoparticles (Ag/Cu-NPs) and thiol-functionalized heparin (Hep-SH) using a rapid polydopamine (PDA) deposition technique, effectively mimicking the ocular surface glycocalyx structure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!