Value of scintigraphy in chronic peritoneal dialysis patients.

Kidney Int

New Haven CAPD, Renal Research Institute, Department of Medicine, Saint Raphael Hospital and Yale University School of Medicine, New Haven, Connecticut 06511, USA.

Published: March 1999

Background: A variety of factors can adversely impact chronic peritoneal dialysis (CPD) as an effective renal replacement therapy for patients with end-stage renal disease. These factors include peritonitis, poor clearances, loss of ultrafiltration, and a variety of anatomic problems, such as hernias, peritoneal fluid leaks, loculations, and catheter-related problems caused by omental blockage. This study reviews our experience with peritoneal scintigraphy for the evaluation of some of these difficulties.

Methods: From 1991 to 1996, 50 peritoneal scintigraphy scans were obtained in 48 CPD patients. Indications for scintigraphy were evaluated, and the patients were placed into four groups: group I, abdominal wall swelling; group II, inguinal or genital swelling; group III, pleural fluid; and group IV, poor drainage and/or poor ultrafiltration. A peritoneal scintigraphy protocol was established and the radiotracer isotope that was used was 2.0 mCi of 99mtechnetium sulfur colloid placed in two liters of 2.5% dextrose peritoneal dialysis solution.

Results: Ten scans were obtained to study abdominal wall swelling, with seven scans demonstrating leaks; six of these episodes improved with low-volume exchanges. Twenty scans were obtained to evaluate inguinal or genital swelling, and 10 of these had scintigraphic evidence for an inguinal hernia leak (9 of these were surgically corrected). One of four scans obtained to evaluate a pleural fluid collection demonstrated a peritoneal-pleural leak that corrected with a temporary discontinuation of CPD. Sixteen scans were obtained to assess poor drainage and/or ultrafiltration. Five of these scans demonstrated peritoneal location, and all of these patients required transfer to hemodialysis. The other 11 scans were normal; four patients underwent omentectomies, allowing three patients to continue with CPD.

Conclusion: Peritoneal scintigraphy is useful in the evaluation and assessment of CPD patients who develop anatomical problems (such as anterior abdominal, pleural-peritoneal, inguinal, and genital leaks) and problems with ultrafiltration and/or drainage.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1523-1755.1999.0550031111.xDOI Listing

Publication Analysis

Top Keywords

peritoneal scintigraphy
16
peritoneal dialysis
12
inguinal genital
12
peritoneal
9
chronic peritoneal
8
patients
8
scintigraphy evaluation
8
scans
8
cpd patients
8
abdominal wall
8

Similar Publications

Purpose: Radionuclide-labeled fibroblast activation protein inhibitor (FAPI) is an emerging tumor tracer. We sought to assess the uptake and diagnostic performance of F-FAPI-42 PET/CT compared with simultaneous 2-deoxy-2[F]fluoro-D-glucose (F-FDG) PET/CT in primary and metastatic lesions in patients with malignant digestive system neoplasms and to determine the potential clinical benefit.

Procedures: Forty-two patients (men = 30, women = 12, mean age = 56.

View Article and Find Full Text PDF

Peritoneopericardial leakage is a rare but important complication of peritoneal dialysis. Peritoneal scintigraphy is reported to be effective in diagnosing the peritoneopericardial communication. Although switching to hemodialysis is commonly recommended, reducing exchange volumes and performing peritoneal dialysis in an upright sitting position may also be considered particularly in pediatric patients.

View Article and Find Full Text PDF

We report an interesting case of a 64-year-old man with a history of radical prostatectomy for prostate cancer. The patient presented with steady increasing prostate-specific antigen levels, but with negative findings on previous multiple conventional prostate-specific membrane antigen (PSMA) PET/CT (with [68Ga]Ga-PSMA-11) and [18F]FDG PET/CT. A recently introduced PSMA tracer using long-lived 89Zr (half-life 3.

View Article and Find Full Text PDF

Diagnostic Efficacy of Staging Laparoscopy Compared to CT and PET-CT in Gastric Cancer: A Retrospective Cohort Analysis.

Medicina (Kaunas)

December 2024

Gastroenterology Surgery Clınıc, Koşuyolu Hıgh Specıalızatıon Educatıon and Research Hospıtal, University of Health Sciences, 34147 Istanbul, Turkey.

: This study aimed to assess the diagnostic accuracy and prognostic significance of staging laparoscopy (SL) compared to computed tomography (CT) and positron emission tomography-computed tomography (PET-CT) in gastric cancer staging. We evaluated the ability of SL to detect occult peritoneal metastases and influence of SL on survival outcomes across cancer stages and treatment approaches. : In this retrospective cohort study, 95 patients with gastric cancer underwent preoperative assessment using CT, PET-CT, and SL between 2018 and 2024.

View Article and Find Full Text PDF

Purpose: To evaluate organ-specific response to [Lu]DOTATATE Peptide Receptor Radionuclide Therapy (PRRT) in patients with small intestine neuroendocrine tumor (SiNET) through [Ga]DOTATOC PET/CT, and to analyze tumor uptake and functional volume variations at different metastatic sites in relation to disease progression during clinical follow-up after treatment.

Methods: A retrospective analysis was conducted on 33 metastatic patients. PET/CT were performed pre-treatment (PET0), mid-treatment after two PRRT cycles (PET2), and post-treatment (PET4).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!