A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions. | LitMetric

Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

Magn Reson Med

McConnell Brain Imaging Center, Montreal Neurological Institute, McGill University, Quebec, Canada.

Published: January 1999

For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences compared to commonly used echo-planar imaging (EPI) are an increased signal-to-noise ratio and the absence of distortions and artifacts due to magnetic field inhomogeneities. RARE- and GRASE-FAIR are applied to functional brain mapping studies in humans during visual stimulation. Results demonstrate that the presented techniques allow for perfusion maps with higher spatial resolution compared to EPI-FAIR. Relative regional cerebral blood flow change in the occipital cortex during visual stimulation was measured to be 41+/-4% (n = 5). The comparison of FAIR data obtained with RARE and GRASE techniques shows that RARE yields images with the higher signal-to-noise ratio. However, the GRASE technique features a shorter acquisition time and less RF power deposition and is thus better suited for multi-slice acquisitions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18>3.0.co;2-5DOI Listing

Publication Analysis

Top Keywords

perfusion-based functional
8
functional magnetic
8
magnetic resonance
8
resonance imaging
8
single-shot rare
8
rare grase
8
signal-to-noise ratio
8
visual stimulation
8
imaging
4
imaging single-shot
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!