This study analyzed the biomechanical behavior of rigid and nonrigid tooth-implant supported fixed partial dentures. Different implants were used to observe the load distribution over teeth, implants, and adjacent bone using three-dimensional finite element analysis. A simulation of tooth loss of the first and second right molars was created with an implant placed in the second right molar and a prepared tooth with simulated periodontal ligament (PDL) in the second right premolar.
View Article and Find Full Text PDFObjective: This study evaluated the influence of carbamide peroxide, 10% and 16%, on the surface roughness and gloss of a pressable ceramic.
Materials And Methods: Carbamide peroxide (10% or 16%) was applied for 4 hours or 3 hours per day for 14 days, respectively, in pressable ceramic discs (14 mm × 2 mm). Specimens were stored in distilled water at 37°C.
Purpose: The objective of this study was to evaluate the marginal fit and the flexural resistance of nickel-chromium frameworks welded by different techniques, gas-torch, laser, and tungsten inert gas (TIG), compared with that of frameworks made via one-piece casting.
Methods: To evaluate the marginal fit, a master model was fabricated simulating four implants. Transfers and replicas were used to transfer the positions of the implants to the model, using a silicone matrix.
Tooth loss can result in loss of facial esthetics, in addition to its effect on mastication, swallowing, and speech. Adequate planning is required in order for the prosthetic treatment of the teeth and implants to be successful. Here, we present a clinical case demonstrating that improper positioning of an implant can make prosthetic rehabilitation unfeasible, necessitating new surgical and rehabilitation planning to achieve the desired esthetics.
View Article and Find Full Text PDFThere is no consensus in literature regarding the best plan for prosthetic rehabilitation with partial multiple adjacent implants to minimize stress generated in the bone-implant interface. The aim of this study was to evaluate the biomechanical behavior of cemented fixed partial dentures, splinted and nonsplinted, on Morse taper implants and with different types of coating material (ceramic and resin), using photoelastic stress analysis. A photoelastic model of an interposed edentulous space, missing a second premolar and a first molar, and rehabilitated with 4 different types of cemented crowns and supported by 2 adjacent implants was used.
View Article and Find Full Text PDFPurpose: The purpose of this study was to compare the tensile strength of commercially pure titanium dowels and cores cemented with zinc phosphate or resin cements.
Methods: Twenty-one extracted human canines were endodontically treated. The root preparations were accomplished using Largo reamers (10mm in depth and 1.