Based on the assumption that postmortem cerebrospinal fluid (CSF) is contaminated depending on the chosen sampling technique in the forensic setting resulting in bloody or at least hemolytic CSF samples, we systematically documented a total of 183 postmortem CSF samples. These samples were all assessed for their quality and color, regardless of the cause of death or the postmortem interval. The investigations were carried out through subjective assessment of color and turbidity, as well as objective measurements of the optical density (OD) of the CSF supernatants after centrifugation of each sample, with standardized photographic documentation.
View Article and Find Full Text PDFObjective: To investigate the effect of decontamination procedures on the microshear bond strength (μSBS) of blood-contaminated resin-modified glass ionomer cement (RMGIC) bonded to resin composite (RC).
Methods: Eighty RMGIC disc specimens were allocated into 5 groups (n=16). All groups except Group 2 were contaminated with blood.
The significance of biomechanical analyses for forensic time since death estimations has recently been demonstrated. Previous biomechanical analyses successfully discriminated post-mortem brain tissue from tissue with a post-mortem interval of at least one day when held at 20 °C. However, the practical utility of such analyses beyond day one at 20 °C was limited.
View Article and Find Full Text PDFTraumatic brain injury (TBI) is a ubiquitous, common sequela of accidents with an annual prevalence of several million cases worldwide. In forensic pathology, structural proteins of the cellular compartments of the CNS in serum and cerebrospinal fluid (CSF) have been predominantly used so far as markers of an acute trauma reaction for the biochemical assessment of neuropathological changes after TBI. The analysis of endogenous metabolites offers an innovative approach that has not yet been considered widely in the assessment of causes and circumstances of death, for example after TBI.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
March 2024
The course of the middle meningeal vessels can be traced through imprints on the inner table of the human neurocranium. It is as yet unexplored whether these notches lower the load-bearing capacity of the bone when compared to areas that are free of vascular imprints. Here, 310 temporo-parietal samples with and without vascular imprints, from 52 human Crosado-embalmed cadavers, were tested in a three-point bending setup with a half-cylindrical impactor (1 mm radius of curvature) contacting the sample at 11 m/s.
View Article and Find Full Text PDFStress urinary incontinence presents a condition not only found in female elderlies, but also in young athletes participating in high-impact sports such as volleyball or trampolining. Repeated jumps appear to be a predisposing factor. Yet the pathophysiology remains incompletely elucidated to date; especially with regard to the influence of the surrounding buttock tissues including gluteus maximus.
View Article and Find Full Text PDFTime since death estimation is a vital part of forensic pathology. Despite the known tissue degradation after death, the efficacy of using biomechanical tissue properties to estimate time since death remains unexplored. Here, eight brain tissue localizations were sampled from the frontal lobe, parietal lobe, anterior and posterior deep brain, superior colliculi, pons, medulla, and cerebellum of 30 sheep; were then stored at 20 °C; and subsequently subjected to rheometry tests on days zero to four after death.
View Article and Find Full Text PDFObjective: Capsular repair aims to minimize damage to the hip joint capsular complex (HJCC) and subsequent dislocation risk following total hip arthroplasty (THA). Numerous explanations for its success have been advocated, including neuromuscular feedback loops originating from within the intact HJCC. This research investigates the hypothesis that the HJCC contributes to hip joint stability by analyzing HJCC innervation.
View Article and Find Full Text PDFBiomechanical experiments help link tissue morphology with load-deformation characteristics. A tissue-dependent minimum sample number is indispensable to obtain accurate material properties. Stress-strain properties were retrieved from human dura mater and scalp skin, exemplifying two distinct soft tissues.
View Article and Find Full Text PDFObjective: To investigate the influence of blood and saliva contamination on the microshear bond strength (μSBS) between resin-modified glass ionomer cement (RMGIC) and resin composite (RC).
Methods And Materials: Eighty RMGIC discs were allocated into four groups (n=20). Group 1 received universal dental adhesive application in a self-etch mode followed by a build-up with RC.
J Mech Behav Biomed Mater
February 2023
Despite of its assumed role to mitigate brain tissue response under dynamic loading conditions, the human dura mater is frequently neglected in computational and physical human head models. A reason for this is the lack of load-deformation data when the dura mater is loaded dynamically. To date, the biomechanical characterization of the human dura mater predominantly involved quasi-static testing setups.
View Article and Find Full Text PDFRoutine coronal paraffin-sections through the dorsal frontal and parieto-occipital cortex of a total of sixty cases with divergent causes of death were immunohistochemically (IHC) stained with an antibody against TMEM119. Samples of cerebrospinal fluid (CSF) of the same cases were collected by suboccipital needle-puncture, subjected to centrifugation and processed as cytospin preparations stained with TMEM119. Both, cytospin preparations and sections were subjected to computer-assisted density measurements.
View Article and Find Full Text PDFDetermining the biomechanical properties of human tissues commonly involves the immersion or spraying of the tissues to maintain them in a hydrated state. However, the influence of the pH value of these solutions on the biomechanical properties of the tissues is not well understood. This study investigated the effects of the pH value on the biomechanical properties of the collagen-rich human iliotibial band (ITB).
View Article and Find Full Text PDFAccurate biomechanical properties of the human dura mater are required for computational models and to fabricate artificial substitutes for transplantation and surgical training purposes. Here, a systematic literature review was performed to summarize the biomechanical properties of the human dura mater that are reported in the literature. Furthermore, anthropometric data, information regarding the mechanically tested samples, and specifications with respect to the used mechanical testing setup were extracted.
View Article and Find Full Text PDFA high number of victims of mass casualty incidences are identified through their teeth. While forensic odontologists need to have a complex skillset during a disaster victim identification (DVI) response, hands-on training opportunities are rare. In countries with very limited forensic casework, such as New Zealand, many forensic odontologists find it difficult to achieve the number of annual forensic dental identifications required to maintain their credentialling.
View Article and Find Full Text PDFTraumatic brain injury (TBI) is a major cause of death and its accurate diagnosis is an important concern of daily forensic practice. However, it can be challenging to diagnose TBI in cases where macroscopic signs of the traumatic head impact are lacking and little is known about the circumstances of death. In recent years, several post-mortem studies investigated the possible use of biomarkers for providing objective evidence for TBIs as the cause of death or to estimate the survival time and time since death of the deceased.
View Article and Find Full Text PDFThe foot comprises of active contractile and passive connective tissue components, which help maintain stability and facilitate movement during gait. The role of age- or pathology-related degeneration and the presence of fat within muscles in foot function and pain remains unclear. The existence of fat has to date not been quantified or compared between individuals according to age, sex, side or subregion.
View Article and Find Full Text PDFDiagnosing traumatic brain injury (TBI) from body fluids in cases where there are no obvious external signs of impact would be useful for emergency physicians and forensic pathologists alike. None of the previous attempts has so far succeeded in establishing a single biomarker to reliably detect TBI with regards to the sensitivity: specificity ratio in a post mortem setting. This study investigated a combination of body fluid biomarkers (obtained post mortem), which may be a step towards increasing the accuracy of biochemical TBI detection.
View Article and Find Full Text PDFObtaining biomechanical properties of biological tissues for simulation purposes or graft developments is time and resource consuming. The number of samples required for biomechanical tests could be reduced if the load-deformation properties of a given tissue layer could be estimated from adjacent layers or if the biomechanical parameters were unaffected by age, bodyside, sex or post-mortem interval. This study investigates for the first time potential correlations of multiple super-imposed tissue layers using the temporal region of the human head as an area of broad interest in biomechanical modelling.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
January 2022
Accurate biomechanical properties of the human cranial dura mater are paramount for computational head models, artificial graft developments and biomechanical basic research. Yet, it is unclear whether areas of the dura containing meningeal vessels biomechanically differ from avascular areas. Here, 244 dura mater samples with or without vessels from 32 cadavers were tested in a quasi-static uniaxial tensile testing setup.
View Article and Find Full Text PDFA single, specific, sensitive biochemical biomarker that can reliably diagnose a traumatic brain injury (TBI) has not yet been found, but combining different biomarkers would be the most promising approach in clinical and postmortem settings. In addition, identifying new biomarkers and developing laboratory tests can be time-consuming and economically challenging. As such, it would be efficient to use established clinical diagnostic assays for postmortem biochemistry.
View Article and Find Full Text PDFObjectives: Conventional autopsies remain the gold standard of postmortem healthcare quality assurance and help gathering extended knowledge on diseases. In answer to constantly declining autopsy rates non- or minimally invasive autopsy methods were introduced. Ultrasound is a well-established tool for imaging commonly used in clinical practice.
View Article and Find Full Text PDF