Objective: Nearly 60% of migraine patients treated with monoclonal antibodies (mAbs) targeting the calcitonin gene-related peptide (CGRP) pathway experience a ≥ 50% reduction in monthly migraine days (MMD) at 12 weeks compared to baseline (responders). However, approximately half of the patients not responding to anti-CGRP mAbs ≤ 12 weeks do respond ≤ 24 weeks (late responders). We assessed frequency and characteristics of patients responding to anti-CGRP mAbs only > 24 weeks (ultra-late responders).
View Article and Find Full Text PDFThe wide span and high density of lines in its rovibrational spectrum render hydrogen cyanide a useful spectroscopic media for referencing absolute frequencies of lasers in optical communication and dimensional metrology. We determined, for the first time to the best of our knowledge, the molecular transitions' center frequencies of the HCN isotope in the range from 1526 nm to 1566 nm with 1.3 × 10 fractional uncertainty.
View Article and Find Full Text PDFSensors (Basel)
February 2023
Accurate measurements of long distances (in the order of tens of meters or more) are necessary in manufacturing processes of large structures, as, for example, in the aerospace industry. In the most demanding applications, the goal is to achieve a relative accuracy of 10 in the measurement of distances (e.g.
View Article and Find Full Text PDFBackground And Objectives: The identification of predictors of response to antiCGRP mAbs could favor tailored therapies and personalized treatment plans. This study is aimed at investigating predictors of ≥ 50%, ≥ 75% and 100% response at 24 weeks in patients with high-frequency episodic (HFEM: 8-14 days/month) or chronic migraine (CM).
Methods: This is a large, multicenter, cohort, real-life study.
Background: Fremanezumab has demonstrated to be effective, safe, and tolerated in the prevention of episodic or chronic migraine (CM) in randomized, placebo-controlled trials (RCTs). Real-life studies are needed to explore drug effects in unselected patients in routine circumstances and to provide higher generalizability results. This study explores the effectiveness, safety, and tolerability of fremanezumab in a real-life population of individuals affected by high-frequency episodic (HFEM: 8-14 days/month) or CM.
View Article and Find Full Text PDFAppl Neuropsychol Adult
September 2022
Accurate screening for cognitive impairment in alcohol and other drug (AOD) services would help to identify individuals who may need supports to obtain the greatest benefit from substance use disorder (SUD) treatment. At present there is no screening measure that has been developed specifically to detect cognitive impairment in a SUD population. This study examines the psychometric properties of the Brief Executive-function Assessment Tool (BEAT), which was specifically designed for this purpose.
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2020
The symptomatic irreproducibility of data in biomedicine and biotechnology prompts the need for higher order measurements of cells in their native and near-native environments. Such measurements may support the adoption of new technologies as well as the development of research programs across different sectors including healthcare and clinic, environmental control and national security. With an increasing demand for reliable cell-based products and services, cellular metrology is poised to help address current and emerging measurement challenges faced by end-users.
View Article and Find Full Text PDFAims: Bicuspid aortic valve (BAV) is associated with aortic wall alterations. We aimed to detect any correlation between aortic elasticity and genetic and biomolecular patterns of elastin.
Methods And Results: Forty-nine BAV patients (mean age: 38 ± 17.
We describe a VLBI experiment in which, for the first time, the clock reference is delivered from a National Metrology Institute to a radio telescope using a coherent fibre link 550 km long. The experiment consisted of a 24-hours long geodetic campaign, performed by a network of European telescopes; in one of those (Medicina, Italy) the local clock was alternated with a signal generated from an optical comb slaved to a fibre-disseminated optical signal. The quality of the results obtained with this facility and with the local clock is similar: interferometric fringes were detected throughout the whole 24-hours period and it was possible to obtain a solution whose residuals are comparable to those obtained with the local clock.
View Article and Find Full Text PDFThis article deals with the evaluation of the chemical purity of iodine-filled absorption cells and the optical frequency references used for the frequency locking of laser standards. We summarize the recent trends and progress in absorption cell technology and we focus on methods for iodine cell purity testing. We compare two independent experimental systems based on the laser-induced fluorescence method, showing an improvement of measurement uncertainty by introducing a compensation system reducing unwanted influences.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
November 2015
We realize a coherent fiber link for application in very long baseline interferometry (VLBI) for radio astronomy and geodesy. A 550-km optical fiber connects the Italian National Metrological Institute (INRIM) to a radio telescope in Italy and is used for the primary Cs fountain clock stability and accuracy dissemination. We use an ultrastable laser frequency- referenced to the primary standard as a transfer oscillator; at the radio telescope, an RF signal is generated from the laser by using an optical frequency comb.
View Article and Find Full Text PDFWe demonstrate the ability of our hyperspectral imaging device, based on a scanning Fabry-Perot interferometer, to obtain a single hyper-image of a sample marked with different fluorescent molecules, and to unambiguously discriminate them by observing their spectral fingerprints. An experiment carried out with cyanines, fluorescein, and quantum dots emitting in the yellow-orange region, demonstrates the feasibility of multi-labeled fluorescence microscopy without the use of multiple filter sets or dispersive means.
View Article and Find Full Text PDFIn this paper we present a new hyperspectral imager based on a Fabry-Perot interferometer with low reflectivity dielectric mirrors. This set-up has been validated by measuring hypercubes of scenes containing emitting bodies and reflective surfaces in the visible region and compared with success with reference spectra. The system is based on dielectric mirrors which, with respect to similar systems based on metallic mirrors, have lower losses at lower cost and are available off-the-shelf.
View Article and Find Full Text PDFAn imaging spectrometer based on a Fabry-Perot interferometer is presented. The Fabry-Perot interferometer scans the mirror distance up to contact and the intensity modulated light signal is transformed using a Fourier Transform based algorithm, as the Michelson based Fourier Transform Spectrometers does. The resulting instrument has the advantage of a compact, high numerical aperture, high luminosity hyperspectral imaging device.
View Article and Find Full Text PDFLibraries of succinamic acid derivatives resulting from the condensation of a series of succinic acid derivatives with amines are reported as putative khafrefungin analogues. A total of 480 compounds derived from the initial condensation of 8 scaffolds with 60 different amines have been synthesized using automated technology with the help of scavenger resins. A simple acetate hydrolysis of five of the above sublibraries afforded additional 300 compounds for a total of 780 compounds.
View Article and Find Full Text PDFLibraries of N-substituted aminocyclitol derivatives of the scyllo and racemic chiro series by means of parallel solution-phase methodology with the help of robotic technology are described. Chemical diversity has been introduced by reaction of selected scaffolds with a set of aldehydes, acyl chlorides, sulfonyl chlorides, chloroformates, and amines to afford the corresponding amines, amides, sulfonamides, carbamates and ureas, respectively. The optimized methodology has proven excellent, in terms of overall purities of the resulting libraries, for the production of amides.
View Article and Find Full Text PDFThe first international comparison of femtosecond laser combs has been carried out at the International Bureau of Weights and Measures (BIPM). Three comb systems were involved: BIPM-C1 and BIPM-C2 from the BIPM and ECNU-C1 from the East China Normal University (ECNU). The agreement among the three combs was found to be on the subhertz level in the vicinity of 563 THz.
View Article and Find Full Text PDFA femtosecond laser-based optical frequency synthesizer is referenced to an optical standard, and we use it to demonstrate the generation and control of the frequency of electromagnetic fields over 100 terahertz of bandwidth with fractional uncertainties approaching 1 part in 10(19). The reproducibility of this performance is verified by comparison of different types of femtosecond laser-based frequency synthesizers from three laboratories.
View Article and Find Full Text PDFWe investigated 19 patients affected by chronic peripheral neurological disorders treated with therapeutic plasma exchange (TPE) to verify the efficacy of the therapeutic protocol used in these diseases. Every patient was clinically considered after 5 TPE. Those who showed an improvement started chemotherapy and continued TPE at the rate of 2 procedures/week for 2 weeks, then 1 procedure/week for 1 month and finally 1 procedure every 2 weeks for 2 months.
View Article and Find Full Text PDFSynthesis and cytotoxicity of the new analogs (11-13) of docetaxel possessing cyclohexyl groups instead of phenyl groups at the C-3' and/or C-2 benzoate positions are described. The C-2 cyclohexanecarboxylate analog of paclitaxel (15) is also synthesized for comparison. The potency of these new taxoids were examined for their inhibitory activity for microtubule disassembly and also for their cytotoxicity against murine P388 leukemia cell line as well as doxorubicin-resistant P388 leukemia cell line (P388/Dox).
View Article and Find Full Text PDF