Introduction: Indications for stress-cardiovascular magnetic resonance imaging (CMR) to assess myocardial ischemia and viability are growing. First pass perfusion and late gadolinium enhancement (LGE) have limited value in balanced ischemia and diffuse fibrosis. Quantitative perfusion (QP) to assess absolute pixelwise myocardial blood flow (MBF) and extracellular volume (ECV) as a measure of diffuse fibrosis can overcome these limitations.
View Article and Find Full Text PDFPurpose: Superimposing soft tissue and bony structures in computed tomography (CT) of the cervical spine (C-spine) is a limiting factor in optimizing radiation exposure maintaining an acceptable image quality. Therefore, we assessed image quality of dose-optimized (DO) C-spine CT in patients capable of shoulder pull-down in an emergency setting.
Methods And Materials: DO-CT (105mAs/120 kVp) of the C-spine in trauma settings was performed in patients with shoulder pull-down if C5 was not superimposed by soft tissue on the lateral topogram, otherwise standard-dose (SD)-CT (195 mAs/120 kVp) was performed.
Objectives: The aim of this study was to compare image quality, conspicuity, and endoleak detection between single-energy low-kV images (SEIs) and dual-energy low-keV virtual monoenergetic images (VMIs+) in computed tomography angiography of the aorta after endovascular repair.
Materials And Methods: An abdominal aortic aneurysm phantom simulating 36 endoleaks (2 densities; diameters: 2, 4, and 6 mm) in a medium- and large-sized patient was used. Each size was scanned using single-energy at 80 kVp (A) and 100 kVp (B), and dual-energy at 80/Sn150kVp for the medium (C) and 90/Sn150kVp for the large size (D).
Objectives: Compare incidence of over-scanning in chest CT among six hospitals and impact on effective and organ effective radiation dose.
Methods: Scout images of 600 chest CTs from six hospitals (A-F) were retrospectively reviewed using a radiation dose tracking software (RTS). Optimal scan range was determined and compared to the actual scan range.
Objective: The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels.
Materials And Methods: Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software.
Purpose: The aims of this study were twofold. First, we investigated the extent of changes in arterial peak enhancement and changes in the duration of a diagnostic arterial enhancement when small amounts of CA volumes (≤30mL) were administered at varying tube voltages. Second, we investigated how to optimize CA injection protocols for CT-angiography with long scan times at various tube voltages to achieve optimal vascular enhancement at the lowest reasonable CA dose.
View Article and Find Full Text PDFAbdom Radiol (NY)
October 2017
Purpose: To assess the accuracy of iodine quantification in a phantom study at different radiation dose levels with dual-energy dual-source CT and to evaluate image quality and radiation doses in patients undergoing a single-energy and two dual-energy abdominal CT protocols.
Methods: In a phantom study, the accuracy of iodine quantification (4.5-23.
Objectives: To evaluate the impact of model-based iterative reconstruction (MBIR) on image quality and low-contrast lesion detection compared with filtered back projection (FBP) in abdominal computed tomography (CT) of simulated medium and large patients at different tube voltages.
Methods: A phantom with 45 hypoattenuating lesions was placed in two water containers and scanned at 70, 80, 100, and 120 kVp. The 120-kVp protocol served as reference, and the volume CT dose index (CTDI) was kept constant for all protocols.
Background Bone subtraction radiography allows reading pulmonary changes of chest radiographs more accurately without superimposition of bones. Purpose To evaluate the value of bone subtraction chest radiography using dual energy (DE) bone subtracted lung images compared to conventional radiographs (CR) in adult patients with cystic fibrosis (CF). Material and Methods Forty-nine DE radiographs of 24 patients (16 men) with CF (mean age, 32 years; age range, 18-71 years) were included.
View Article and Find Full Text PDFObjective: The aim of this study was to investigate the image quality, radiation dose, and accuracy of virtual noncontrast images and iodine quantification of split-filter dual-energy computed tomography (CT) using a single x-ray source in a phantom and patient study.
Materials And Methods: In a phantom study, objective image quality and accuracy of iodine quantification were evaluated for the split-filter dual-energy mode using a tin and gold filter. In a patient study, objective image quality and radiation dose were compared in thoracoabdominal CT of 50 patients between the standard single-energy and split-filter dual-energy mode.
Objective: The purpose of this article is to investigate the magnitude of dose optimization for a manufacturer-recommended urolithiasis protocol in a second-generation dual-source CT scanner.
Materials And Methods: Custom renal phantoms with 24 stones were scanned using the manufacturer-provided dual-energy CT protocol (tube A, 100 kVp and 210 reference mAs; tube B, 140 kVp and 162 reference mAs) and seven dose-optimized protocols in which the reference tube current-time product setting of tube A was reduced stepwise by 20 mAs. Detection and characterization of the stones was assessed.
Objectives: Organ-based tube current modulation aims to reduce exposure to radiosensitive organs like the breasts by considering their anatomical location and altering tube current during rotation. Former phantom studies demonstrated a dose reduction of 20-37 %. Our study aimed to estimate the potential of dose reduction with this technique in relation to the actual location of breast tissue in a large clinical cohort.
View Article and Find Full Text PDFBackground: The accuracy of CT pulmonary angiography (CTPA) in detecting or excluding pulmonary embolism has not yet been assessed in patients with high body weight (BW).
Methods: This retrospective study involved CTPAs of 114 patients weighing 75-99 kg and those of 123 consecutive patients weighing 100-150 kg. Three independent blinded radiologists analyzed all examinations in randomized order.
Objectives: To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA.
Methods: In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated.
Objective: The objective of the study was to test the diagnostic performance of low-dose computed tomography pulmonary angiography (CTPA) at peak tube voltage of 80 kVp with both reduced radiation and reduced contrast material (CM) dose.
Materials And Methods: In this single-center, single-blinded prospective randomized trial, 501 patients with body weights of less than 100 kg with suspected acute pulmonary embolism (PE) were assigned to normal-dose CTPA (100-kVp tube energy and 100-mL CM, 255 patients) and low-dose CTPA (80-kVp tube energy and 75-mL CM, 246 patients). Primary end points were evidence of PE in CTPA and accuracy of CTPA on a composite reference standard.
Objective: The purpose of this study was to assess the impact of a noise reduction technique on image quality, radiation dose, and low-contrast detectability in abdominal CT for obese patients.
Materials And Methods: A liver phantom with 12 different tumors was designed, and fat rings were added to mimic intermediately sized and large patients. The intermediate and large phantoms were scanned with our standard abdominal CT protocol (image noise level of 15 HU and filtered back projection [FBP]).
Objectives: The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD.
Methods: An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp).
Objectives: To determine the value of combined automated attenuation-based tube-potential selection and iterative reconstructions (IRs) for optimising computed tomography (CT) imaging of hypodense liver lesions.
Methods: A liver phantom containing hypodense lesions was imaged by CT with and without automated attenuation-based tube-potential selection (80, 100 and 120 kVp). Acquisitions were reconstructed with filtered back projection (FBP) and sinogram-affirmed IR.
Purpose: To compare the low-contrast detectability and image quality of computed tomography (CT) at different radiation dose levels reconstructed with iterative reconstruction (IR) and filtered back projection (FBP).
Materials And Methods: A custom liver phantom with 12 simulated hypoattenuating tumors (diameters of 5, 10, 15, and 20 mm; tumor-to-liver contrast values of -10, -20, and -40 HU) was designed. The phantom was scanned with a standard abdominal CT protocol with a volume CT dose index of 21.
Objective: The objective of our study was to compare the effect of dual-energy subtraction and bone suppression software alone and in combination with computer-aided detection (CAD) on the performance of human observers in lung nodule detection.
Materials And Methods: One hundred one patients with from one to five lung nodules measuring 5-29 mm and 42 subjects with no nodules were retrospectively selected and randomized. Three independent radiologists marked suspicious-appearing lesions on the original chest radiographs, dual-energy subtraction images, and bone-suppressed images before and after postprocessing with CAD.
Purpose: To determine the frequency of apparent acute pulmonary embolism (PE) and of concomitant disease in computed tomography pulmonary angiography (CTPA); to compare the frequency of PE in patients with pneumonia or acute cardiac disorder (acute coronary syndrome, tachyarrhythmia, acute left ventricular heart failure or cardiogenic shock), with the frequency of PE in patients with none of these alternative chest pathologies (comparison group).
Methods: Retrospective analysis of all patients who received a CTPA at the emergency department (ED) within a period of four years and 5 months.
Results: Of 1275 patients with CTPA, 28 (2.
Purpose: To identify reasons for ordering computed tomography pulmonary angiography (CTPA), to identify the frequency of reasons for CTPA reflecting defensive behavior and evidence-based behavior, and to identify the impact of defensive medicine and of training about diagnosing pulmonary embolism (PE) on positive results of CTPA.
Methods: Physicians in the emergency department of a tertiary care hospital completed a questionnaire before CTPA after being trained about diagnosing PE and completing questionnaires.
Results: Nine hundred patients received a CTPA during 3 years.
Objective: To assess the effect of tumor size and tumor-to-liver contrast of simulated hypovascular liver tumors on the diagnostic accuracy of hepatic computed tomography (CT).
Materials And Methods: This retrospective study was approved by the institutional review board, and informed consent was waived. A total of 153 simulated hypovascular liver tumors were embedded in 70 hepatic CT data sets that were acquired during the portal venous phase.