Publications by authors named "Ziren Wan"

In dense nonaqueous phase liquid (DNAPL) contaminant source zones, aqueous concentrations of trichloroethene (TCE) in groundwater may approach saturation levels (8.4 mM). It is generally believed that such saturation concentrations are toxic to organohalide-respiring bacteria (OHRB), thus limiting the effectiveness of bioremediation.

View Article and Find Full Text PDF

The coupling of thermal remediation with microbial reductive dechlorination (MRD) has shown promising potential for the cleanup of chlorinated solvent contaminated sites. In this study, thermal treatment and bioaugmentation were applied in series, where prior higher thermal remediation temperature led to improved TCE dechlorination performance with both better organohalide-respiring bacteria (OHRB) colonization and electron donor availability. The 60 °C was found to be a key temperature point where the promotion effect became obvious.

View Article and Find Full Text PDF

PFASs and chlorinated solvents are the common co-contaminants in soil and groundwater at firefighter training areas (FTAs). Although PFASs mixtures could have adverse impacts on bioremediation of trichloroethylene (TCE) by inhibiting Dehalococcoides (Dhc), little is known about the effect and contribution of PFOA or PFOS on dechlorination of TCE by non-Dhc organohalide-respiring bacteria (OHRB). To study this, PFOA and PFOS were amended to the growth medium of a non-Dhc OHRB-containing enrichment culture to determine the impact on dechlorination.

View Article and Find Full Text PDF

Successful remediation of semi-volatile contaminants using electrical resistance heating (ERH) coupled technologies requires a deep understanding of contaminant migration and accessibility, especially with stratigraphic heterogeneity and dense nonaqueous phase liquid (DNAPL) occurrence. Here, we chose nitrobenzene (NB) as a model contaminant of semi-volatile DNAPL and uniquely demonstrated that temperature variation during ERH could induce NB DNAPL migration out of the low permeability zone (LPZ) even below water boiling temperature. When heating the system using alternating current (AC) of 140 V to a temperature range of 50-79 °C, obvious DNAPL migration was visually observed.

View Article and Find Full Text PDF

Fire-training areas (FTAs) are an important source of perfluoroalkyl and polyfluoroalkyl substances (PFASs) pollution. However, the effect of PFASs on soil bacterial communities remains limited. Here, we detected the PFASs in soils ranging from 3.

View Article and Find Full Text PDF