Aims: Transvenous lead extraction (TLE) is important in the management of cardiac implantable electronic devices but carries risk. It is most commonly completed from the superior access, often with 'bail-out' support via the femoral approach. Superior and inferior access may be used in tandem, which has been proposed as an advance in safety and efficacy.
View Article and Find Full Text PDFIntroduction: The IMPACT study established the role of controlled esophageal cooling in preventing esophageal thermal injury during radiofrequency (RF) ablation for atrial fibrillation (AF). The effect of esophageal cooling on ablation lesion delivery and procedural and patient outcomes had not been previously studied. The objective was to determine the effect of esophageal cooling on the formation of RF lesions, the ability to achieve procedural endpoints, and clinical outcomes.
View Article and Find Full Text PDFRecent decades have seen a series of advances in percutaneous transvenous procedures for cardiac arrhythmias, including the implantation of leadless pacemakers. Many of these procedures require the insertion of large caliber sheaths in large veins, usually the femoral vein. Securing hemostasis efficiently and reliably at the access site is a key step to improving a procedure's safety profile.
View Article and Find Full Text PDFA 39-years old ventricular lead of a right-sided single-chamber pacemaker required extraction for infection. Angulation at the right subclavian-superior vena cava junction coupled with calcified fibrotic encapsulating tissue prevented advancement of a rotational dissecting sheath. To straighten the lead, it was pulled from the subclavian and out of the right internal jugular vein, whilst the Needle's-Eye Snare via the femoral access provided counter-traction.
View Article and Find Full Text PDFAims: To investigate the abnormalities of the coronary venous system in candidates for cardiac resynchronization therapy (CRT) and describe methods for circumventing the resulting difficulties.
Methods: From four implanting institutes, data of all CRT implants between October 2008 and October 2020 were screened for abnormal cardiac venous anatomy, defined as an anatomical variation not conforming to the accepted 'normal' anatomy. Patient demographics, procedural detail, and subsequent left ventricle (LV) lead pacing indices were collected.
COVID-19 causes severe illness that results in morbidity and mortality. Electrocardiographic features, including QT prolongation, have been associated with poor acute outcomes; data on the medium-term outcomes remain scarce. This study evaluated the 1-year outcomes of patients who survived the acute COVID-19 infection.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2022
Background: Transvenous lead extraction (TLE) is rising in parallel to cardiac implantable electronic device implantations. Persistent left side superior vena cava (PLSVC) is a relatively common anatomical variant in the healthy population; TLE in patients with a PLSVC is rare.
Method: Data were collated from 6 European TLE institutes of 10 patients who had undergone lead extraction with a PLSVC.
Background: The Sars-Cov-2 infection is a multisystem illness that can affect the cardiovascular system. Tachyarrhythmias have been reported but the prevalence of bradyarrhythmia is unclear. Cases have been described of transient high-degree atrioventricular (AV) block in COVID-19 that were managed conservatively.
View Article and Find Full Text PDFBackground: Cardiac implantable electronic device (CIED)-related perforation is uncommon but potentially lethal. Management typically includes the use of computed tomography (CT) scanning and often involves cardiac surgery.
Methods: Patients presenting to a single referral centre with CIED-related cardiac perforation between 2013 and 2019 were identified.
J Cardiovasc Electrophysiol
April 2021
Background: Cardiac resynchronization therapy-defibrillator (CRT-D) implantation via the cephalic vein is feasible and safe. Recent evidence has suggested a higher implantable cardioverter-defibrillator (ICD) lead failure in multi-lead defibrillator therapy via the cephalic route. We evaluated the relationship between CRT-D implantation via the cephalic and ICD lead failure.
View Article and Find Full Text PDFAims: Thermal injury to the oesophagus is an important cause of life-threatening complication after ablation for atrial fibrillation (AF). Thermal protection of the oesophageal lumen by infusing cold liquid reduces thermal injury to a limited extent. We tested the ability of a more powerful method of oesophageal temperature control to reduce the incidence of thermal injury.
View Article and Find Full Text PDFAims: Restoring sinus rhythm (SR) by ablation alone is an endpoint used in radiofrequency (RF) ablation for long-standing persistent atrial fibrillation (AF) but not with cryotherapy. The simultaneous use of two cryotherapy catheters can improve ablation efficiency; we compared this with RF ablation in chronic persistent AF aiming for termination to SR by ablation alone.
Methods And Results: Consecutive patients undergoing their first ablation for persistent AF of >6 months duration were screened.
Background: Small series has shown that cardiac resynchronisation therapy (CRT) can be achieved in a majority of patients using exclusively cephalic venous access. We sought to determine whether this method is suitable for widespread use.
Methods: A group of 19 operators including 11 trainees in three pacing centres attempted to use cephalic access alone for all CRT device implants over a period of 8 years.
Purpose: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter.
Methods: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter.
J Interv Card Electrophysiol
November 2019
Background: The use of remanufactured single-use devices (SUDs), including cardiac electrophysiology catheters, has become established in the USA and other health care systems but without much published scientific evaluation on the relative safety or efficacy of these devices. In the United Kingdom (UK), the use of remanufactured SUDs has not been routine. We performed a structured evaluation of the safety and efficacy of a remanufactured circular mapping catheter (Stryker® remanufactured Lasso NAV 2515) during its introduction in our centre.
View Article and Find Full Text PDFBackground: Idiopathic ventricular ectopy (VE) shows predilection to sites within the left ventricular (LV) base such as the outflow tract/aortic sinuses, LV summit, and areas adjacent to the aortomitral continuity. We characterize VE arising from the inferior septum of the LV base that was successfully managed by LV endocardial ablation from the inferoseptal recess of the LV.
Objective: The purpose of this study was to determine the incidence, electrocardiographic (ECG) findings, electrophysiological findings, and anatomical features associated with VE arising from the basal inferoseptal process of the LV (ISP-LV) ablated using an LV endocardial approach via the inferoseptal recess of the LV.
Aim: The Biosense Webster ThermoCool® SmartTouch® Surround Flow (STSF) catheter is a recently developed ablation catheter incorporating Surround Flow (SF) technology to ensure efficient cooling and force sensing to quantify tissue contact. In our unit, it superseded the ThermoCool® SF catheter from the time of its introduction in May 2015.
Methods And Results: Procedure-related data were collected prospectively for the first 100 ablation procedures performed in our department using the STSF catheter.
Background: We have described the use of femoral access followed by pull through of the lead to a pectoral position to circumvent difficulty in implanting a left ventricular (LV) lead by standard methods.
Objective: The purpose of this study was to establish the effect of femoral implantation and pull through on the overall rate of success in percutaneous implantation of LV leads.
Methods: We collected data prospectively in all attempts at LV lead implantation from the time that we envisioned the femoral pull-through approach.
Purpose: The purpose of this study is to establish the role of Achieve Mapping Catheter in cryoablation for paroxysmal atrial fibrillation (PAF) in a randomized trial.
Methods: A total of 102 patients undergoing their first ablation for PAF were randomized at 2:1 to an Achieve- or Lasso-guided procedure. Study patients were systematically followed up for 12 months with Holter monitoring.
Indian Pacing Electrophysiol J
January 2014
We describe a patient presenting with incessant ectopic atrial tachycardia during a high risk twin pregnancy. Tachycardia was resistant to escalating doses of beta-blockade with digoxin. Because of increasing left ventricular dysfunction early in the third trimester, catheter ablation was performed successfully at 30 weeks gestation.
View Article and Find Full Text PDF