This study evaluated the feasibilities and outcomes following four-dimensional magnetic resonance imaging (4D-MRI) assisted stereotactic body radiation therapy (SBRT) for unresectable colorectal liver metastases (CRLMs). From March 2018 to January 2022, we identified 76 unresectable CRLMs patients with 123 lesions who received 4D-MRI guided SBRT in our institution. 4D-MRI simulation with or without abdominal compression was conducted for all patients.
View Article and Find Full Text PDFPurpose: Anatomical changes occurred during the treatment course of radiation therapy for lung cancer patients may introduce clinically unacceptable dosimetric deviations from the planned dose. Adaptive radiotherapy (ART) can compensate these dosimetric deviations in subsequent treatments via plan adaption. Determining whether and when to trigger plan adaption during the treatment course is essential to the effectiveness and efficiency of ART.
View Article and Find Full Text PDFMedical exposure to ionizing irradiation has become a recognised carcinogenic risk. Balancing the concomitant imaging dose and positioning accuracy is critical in image-guided-radiotherapy (IGRT) especially for children, whose higher biological susceptibility and longer expected life make them more vulnerable to develop secondary cancer. This work aims to evaluate and benchmark the imaging dose and positioning accuracy of a new MV cone-beam-CT (CBCT)-guided IGRT system, Varian Halcyon, against conventional kV CBCT.
View Article and Find Full Text PDFPurpose: Through the Monte Carlo (MC) simulation of 6 and 10 MV flattening-filter-free (FFF) beams from Varian TrueBeam accelerator, this study aims to find the best incident electron distribution for further studying the small field characteristics of these beams.
Methods: By incorporating the training materials of Varian on the geometry and material parameters of TrueBeam Linac head, the 6 and 10 MV FFF beams were modelled using the BEAMnrc and DOSXYZnrc codes, where the percentage depth doses (PDDs) and the off-axis ratios (OARs) curves of fields ranging from 4 × 4 to 40 × 40 cm(2) were simulated for both energies by adjusting the incident beam energy, radial intensity distribution and angular spread, respectively. The beam quality and relative output factor (ROF) were calculated.
Int J Radiat Oncol Biol Phys
November 2015
Purpose: Kilovoltage cone beam computed tomography (CT) (kVCBCT) imaging guidance improves the accuracy of radiation therapy but imposes an extra radiation dose to cancer patients. This study aimed to investigate concomitant imaging dose and associated cancer risk in image guided thoracic radiation therapy.
Methods And Materials: The planning CT images and structure sets of 72 patients were converted to CT phantoms whose chest circumferences (Cchest) were calculated retrospectively.
Purpose: To compare the dosimetric differences between jaw tracking technique (JTT) and static jaw technique (SJT) in dynamic intensity-modulated radiotherapy (d-IMRT) and assess the potential advantages of jaw tracking technique.
Methods: Two techniques, jaw tracking and static jaw, were used respectively to develop the d-IMRT plans for 28 cancer patients with various lesion sites: head and neck, lungs, esophageal, abdominal, prostate, rectal and cervical. The dose volume histograms (DVH) and selected dosimetric indexes for the whole body and for organs at risk (OARs) were compared.