Background And Aims: Ultrathin EGD (UT-EGD) is an ideal tool for unsedated upper GI examination and pediatric gastroenterology but is rarely competent for EUS miniprobe (EUS-MP). We developed a UT-EGD US method (UT-EUS) and verified its clinical application value through animal experiments.
Methods: Five Bama miniature pigs were selected.
IEEE Trans Ultrason Ferroelectr Freq Control
June 2022
High-frequency endoscopic ultrasound (HFEUS) imaging is an important tool commonly used in clinical practice for imaging hollow organs. The virtual source synthetic aperture (VSSA) method is effective in improving the imaging quality of HFEUS. However, interference from the motor control unit severely affects the accuracy of the conventional delay and sum (DAS) method, thus compromising the effectiveness of VSSA.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
June 2021
In this article, a PZT/Epoxy 1-3 piezoelectric composite based on picosecond laser etching technology is developed for the fabrication of high-frequency ultrasonic transducer. The design, fabrication, theoretical analysis, and performance of the piezocomposite and transducer are presented and discussed. According to the test results, the area of the PZT pillar is [Formula: see text], the average width of the kerf is [Formula: see text], and the thickness of the piezocomposite is [Formula: see text].
View Article and Find Full Text PDFPhotoacoustic (PA) imaging is a hybrid imaging technique that can provide both structural and functional information of biological tissues. Due to limited permissible laser energy deposited on tissues, highly sensitive PA imaging is required. Here, we developed a 20 MHz lead zirconium titanate (PZT) transducer (1.
View Article and Find Full Text PDFBiomed Res Int
August 2018
Ultrasound elastography is an imaging modality to evaluate elastic properties of soft tissue. Recently, 1D quasi-static elastography method has been commercialized by some companies. However, its performance is still limited on high strain level.
View Article and Find Full Text PDFDue to the small aperture of blood vessel, a considerable disadvantage to current intravascular ultrasound (IVUS) imaging transducers is that their lateral imaging resolution is much lower than their axial resolution. To solve this problem, a single-element, 50 MHz, 0.6 mm diameter IVUS transducer with a geometric focus at 3 mm was proposed in this paper.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
June 2016
Based on the Fresnel half-wave band interference, a micromachined self-focusing piezoelectric composite ultrasound transducer was proposed in this paper. The theoretical analysis was deduced based on the concept of constructive interference of acoustic waves and electromechanical response of piezoelectric composites. The calculated and simulation results showed that it combined the advantages of composite transducer and plate self-focusing transducer, and can achieve high electromechanical coupling coefficient, low acoustic impedance, high intensity, short focal length and micro size.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
June 2016
In order to design a 50MHz intravascular ultrasound (IVUS) transducer with good pulse-echo responses, in this paper, a finite element model (FEM) was built to simulate the transducer acoustic performances with different layer thicknesses. According to comparisons of the acoustic fields and the admittance curves, the optimum thickness parameters are gained. And then, an IVUS PZT transducer with controlled layer thicknesses was fabricated and tested.
View Article and Find Full Text PDF