Objective: This study aims to evaluate the effects of low tidal volume and positive end expiratory pressure (PEEP) combined with pressure-controlled ventilation-volume guaranteed (PCV-VG) ventilation on one lung ventilation (OLV) in patients with tuberculous destroyed lung (TDL).
Methods: Patients of two groups were all treated with volume controlled ventilation (VCV) on two-lung ventilation, and the tidal volume was set to 8 ml/kg according to standard body weight, breath rate was set to 10-14 times/min, inspiration and expiration ratio was set to 1:1.5.
Background: Previous studies have demonstrated that Helicobacter pylori is a critical factor in the development of gastrointestinal diseases. However, only limited studies have reported results on the relationship between H pylori infection and patients with type 2 diabetes mellitus (T2DM). Moreover, the conclusions from these past studies are variable.
View Article and Find Full Text PDFObjective: This study aims to evaluate the effects of low tidal volume and positive end expiratory pressure (PEEP) combined with pressure-controlled ventilation-volume guaranteed (PCV-VG) ventilation on one lung ventilation (OLV) in patients with tuberculous destroyed lung (TDL).
Methods: Patients of two groups were all treated with volume controlled ventilation (VCV) on two-lung ventilation, and the tidal volume was set to 8 ml/kg according to standard body weight, breath rate was set to 10-14 times/min, inspiration and expiration ratio was set to 1:1.5.
Chiral stationary phases (CSPs) have always been research hotspot in enantiomer separation. Currently, most of the CSPs are based on silica platform. In this research, monodisperse, porous glycidyl methacrylate-divinylbenzene copolymer particles (poly(GMA-DVB)) were designed and prepared.
View Article and Find Full Text PDFIntroduction: This study aimed to evaluate the effects of dexmedetomidine (DEX) on lung injury, the oxygenation index and perioperative pulmonary complications in elderly patients who underwent thoracotomy with one-lung ventilation (OLV).
Material And Methods: A total of 120 elderly patients with lung cancer were included in the present study. According to the random number table method, these patients were randomly divided into two groups: group D and group C.
In the present study, submicrometer flow-through silica microspheres (Sub-FTSiO) was for the first time obtained via a suspension polymerization method coupled with sol-gel transition and phase separation. The Sub-FTSiO was characteristic of rich mesopores, penetrable macropores and small particle size, which would be beneficial to fast mass transfer, low column backpressure and high column efficiency. It was directly used as the hydrophilic interaction liquid chromatographic (HILIC) stationary phase, and the fast separation of seven water-soluble vitamins in 2.
View Article and Find Full Text PDFBackground: The present study aims to evaluate the influence of alveolar recruitment strategy (ARS) and positive end-expiratory pressure (PEEP) combined with autoflow on respiratory mechanics, the oxygen index (OI), pulmonary shut [Qs/Qt(%)], and the concentrations of IL-6 and TNF-α in venous blood after surgery in obese patients who experienced thoracic surgery with one-lung ventilation (OLV).
Methods: A total of 36 obese patients with ASAII-III degree, who experienced selective pulmonary lobectomy, were within 36-74 years old, and had a BMI of 30-40 kg/m, were randomly divided into two groups: control group (C group) and protective ventilation group (P group). In the P group, ARS was given once when OLV began.
In this study, the ethyl-bridged hybrid silica microsphere with hierarchically meso-macroporous structure was initially synthesized through a method combining dispersion polymerization with sol-gel transition and phase separation. The flow-through macropores rendered the microsphere a rough surface like a waxberry, and thus the material was named as waxberry-like ethyl-bridged hybrid silica sphere (WEHS). WEHS was characteristic of appropriate alkali-stability, which was highly difficult for the pure silica.
View Article and Find Full Text PDFIn the present study, a polar-embedded reversed-phase liquid chromatographic stationary phase that contained internal sulfone groups was prepared. The synthesis involved the "thiol-ene" click chemistry between the vinyl functionalized silica and 1-octadecanethiol, followed by the oxidization of sulfide to sulfone groups. The resulting material simultaneously possessed the alkyl chain, i.
View Article and Find Full Text PDFThe demand for fast chromatographic enantioseparation aroused the hot research in stationary phase matrix. In the present study, the flow-through silica, which is characterized by hierarchical pores of through pores in several hundred nanometer range and mesopores about 20nm, was attempted for fast enantioseparation. Thanks to the large surface area and full openness of the through pores, the flow-through silica had comparable cellulose derivative loading amount as the commercial wide-pore silica, which was impracticable for most of the core-shell particles and sub-2-μm fully porous silica.
View Article and Find Full Text PDFThe aim of the present study was to investigate the effect of penehyclidine (PHC) on endotoxin-induced acute lung injury (ALI), as well as to examine the mechanism underlying this effect. A total of 60 rats were randomly divided into five groups, including the control (saline), LPS and three LPS + PHC groups. ALI was induced in the rats by injection of 8 mg lipopolysaccharide (LPS)/kg body weight.
View Article and Find Full Text PDFOctadecyl bonded silica (ODS) is the most popular packing for reversed-phase chromatography. However, it generally demonstrates bad resolution for polar analytes because of the residue silanols and its poor stability in aqueous mobile phase. To address the problem, a new reversed-phase packing containing both polar-embedded and polar-endcapped moieties was proposed.
View Article and Find Full Text PDFA mixed-mode chromatographic stationary phase, C18-DTT (dithiothreitol) silica (SiO2) was prepared through "thiol-ene" click chemistry. The obtained material was characterized by fourier transform infrared spectroscope, nitrogen adsorption analysis and contact angle analysis. Chromatographic performance of the C18-DTT was systemically evaluated by studying the effect of acetonitrile content, pH, buffer concentration of the mobile phase and column temperature.
View Article and Find Full Text PDFA novel nickel oxide nanoparticle-deposited silica (SiO2@NiO) composite was prepared via liquid-phase deposition (LPD) and then employed as a solid-phase extraction (SPE) sorbent. When the SPE was coupled with liquid chromatography-electrospray ionization mass spectrometry (LC-ESI/MS) analysis, an analytical platform for the sensitive determination of benzimidazole residues in egg and milk was established. The limits of detection of nine benzimidazoles were in the range of 0.
View Article and Find Full Text PDFIn the current study, novel featured silica, named penetrable silica, simultaneously containing macropores and mesopores, was immobilized with bovine serum albumin (BSA) via Schiff base method. The obtained BSA-SiO2 was employed as the high-performance liquid chromatographic (HPLC) stationary phase. Firstly, D- and L-tryptophan were used as probes to investigate the chiral separation ability of the BSA-SiO2 stationary phase.
View Article and Find Full Text PDFIn the present study, a novel configuration of liquid-phase microextraction was proposed, in which a magnetic stirrer with a groove was used as the extractant phase holder. It was termed as magnetic stirrer liquid-phase microextraction. In this way, the stability of the organic solvent was much improved under high stirring speed; the extraction efficiency was enhanced due to the enormously enlarged contact area between the organic solvent and aqueous phase.
View Article and Find Full Text PDFA mixed-mode chromatographic packing material, C18 and diol groups modified silica (C18-Diol), was prepared with controllable hydrophobicity and hydrophilicity. It demonstrated excellent aqueous compatibility and stability in aqueous mobile phase; compared to the traditional C18 column, improved peak shape of basic analytes was also obtained. Additionally, it exhibited both reversed-phase liquid chromatographic (RPLC) and hydrophilic interaction chromatographic (HILIC) performance; the analyte separation scope was thus enlarged, demonstrated by simultaneous separation of twenty acids, bases and neutrals.
View Article and Find Full Text PDFMagnetic nanoparticles (MNPs) featured with divinylbenzene (DVB) and sulfonate functionalities (Fe3O4-DVB-SO3(-)) were prepared via "thiol-ene" click chemistry. The hydrophobic DVB moieties were dedicated for extraction while the hydrophilic sulfonate groups were designed for dispersing the MNPs in aqueous sample solution. Thus, the specially designed material could ensure operational convenience and improve reproducibility during extraction.
View Article and Find Full Text PDFBenzophenone-type UV filters (BPs) are ubiquitous in the environment. Transformation products (TPs) of BPs with suspected toxicity are likely to be produced during disinfection of water by chlorination. To quickly predict the toxicity of TPs, in this study, a novel two-dimensional liquid-chromatography (2D-LC) method was established in which the objective of the first dimension was to separate the multiple components of the BPs sample after chlorination, using a reversed-phase liquid-chromatography mode.
View Article and Find Full Text PDFThe present study described the preparation and application of zwitterionic stationary phases (ACS) with controllable ratio of positively charged tertiary amine groups and negatively charged carboxyl groups. Various parameters, including water content, pH values and ionic strength of the mobile phase, were investigated to study the chromatographic characteristics of ACS columns. The prepared ACS columns demonstrated a mix-mode retention mechanism composed of surface adsorption, partitioning and electrostatic interactions.
View Article and Find Full Text PDFIn this study, a novel two-dimensional liquid chromatographic (2D-LC) system was developed for simultaneous separation and toxicity prediction of pharmaceutical and its related substances. A conventional ODS column was used on the 1st-D to separate the sample; while, bio-partitioning micellar chromatography served as the 2nd-D to predict toxicity of the components. The established system was tested for the toxicity of ibuprofen and its impurities with known toxicity.
View Article and Find Full Text PDFThe zirconia-coated silica (ZrO2/SiO2) material was obtained by coupling layer-by-layer (LbL) self-assembly method and sol-gel technology, to take dual advantages of the suitable porous structure of SiO2 and basic resistance of ZrO2. Adenosine 5'-monophosphate (5'-AMP) was then self-assembled onto ZrO2/SiO2 via Lewis acid-base interaction, generating 5'-AMP-ZrO2/SiO2. The chromatographic properties of 5'-AMP-ZrO2/SiO2 were systemically studied by evaluating the effect of acetonitrile content, pH and buffer concentration in the mobile phase.
View Article and Find Full Text PDFA rapid analysis method by coupling carbon nanotube film (CNTF) microextraction with desorption corona beam ionization (DCBI) was developed for the determination of Sudan dyes (I-IV) and Rhodamine B in chilli oil samples. Typically, CNTF was immersed into the diluted solution of chilli oil for extraction, which was then placed directly under the visible plasma beam tip of the DCBI source for desorption and ionization. Under optimized conditions, five dyes were simultaneously determined using this method.
View Article and Find Full Text PDFA hydrophilic stationary phase (SP) was prepared through grafting N-methylene phosphonic acid chitosan on magnesia-zirconia particles (P-CTS-MgO-ZrO2) via Lewis acid-base interaction. The resulting material was characterized by thermogravimetric analysis, Fourier transform infrared spectroscopy, scanning electron microscope and nitrogen adsorption analysis. The chromatographic performance of P-CTS-MgO-ZrO2 was systemically evaluated by studying effect of acetonitrile content, pH and buffer concentration in the mobile phase.
View Article and Find Full Text PDFIn the present study, magnetic nanoparticles (MNPs) with phenyl functionalized core and a hydrophilic methylcellulose coating were synthesized. The functionalized MNPs showed excellent dispersibility in aqueous solution and they were applied to magnetic solid phase extraction (MSPE) of sildenafil and its metabolite, desmethyl sildenafil, from human urine and plasma samples followed by high performance liquid chromatographic analysis. The factors that may influence the extraction, including the amount of MNPs, pH and salt concentration of sample solution, extraction and desorption time, and the volume of desorption solvent, were investigated in detail.
View Article and Find Full Text PDF