Pilocytic astrocytoma (PA) is classified as a Grade I benign neuroglial tumor. The extent of surgical resection is a critical factor influencing the prognosis for patients with PA. In prior researches of PA, the extent of surgical resection is generally categorized into GTR, STR and biopsy.
View Article and Find Full Text PDFBackground: The relationship between malnutrition and diabetic retinopathy (DR) is still unclear. The purpose of this study is to investigate the relationship between malnutrition and DR in type 2 diabetic patients.
Methods: A cross-sectional study was conducted on 612 patients with type 2 diabetes mellitus.
Objective: This study aims to examine the clinical significance of ultrasound evaluation of the gastrocnemius muscle (GM) in identifying sarcopenia in patients with type 2 diabetes (T2D).
Methods: One hundred and fifty-three patients with T2D were included in this study. We measured the appendicular skeletal muscle mass index (ASMI), handgrip strength, and 6-meter walking speed.
The coronavirus disease (COVID-19) pandemic has increased pressure to develop low-cost, compact, user-friendly, and ubiquitous virus sensors for monitoring infection outbreaks in communities and preventing economic damage resulting from city lockdowns. As proof of concept, we developed a wearable paper-based virus sensor based on a molecular imprinting technique, using a conductive polyaniline (PANI) polymer to detect the lentivirus as a test sample. This sensor detected the lentivirus with a 4181 TU/mL detection limit in liquid and 0.
View Article and Find Full Text PDFZika virus (ZIKV) became a public health concern when it re-emerged in 2015 owing to its ability to cause congenital deformities in the fetus and neurological complications in adults. Despite extensive data on protection, the interplay of protective and pathogenic adaptive immune responses toward ZIKV infection remains poorly understood. In this study, using a T-cell‒deficient mouse model that retains persistent ZIKV viral titers in the blood and organs, we show that the adoptive transfer of CD8+ T cells led to a significant reduction in viral load.
View Article and Find Full Text PDFIn a pattern of horizontal lines containing ± 45° zigzagging phase-shifted strips, vivid illusory motion is perceived when the pattern is translated up or down at a moderate speed. Two forms of illusory motion are seen: [i] a motion "racing" along the diagonal interface between the strips and [ii] lateral (sideways) motion of the strip sections. We found the relative salience of these two illusory motions to be strongly influenced by the vertical spacing and length of the line gratings, and the period length of the zigzag strips.
View Article and Find Full Text PDFPerfluorinated compounds like perfluorooctanesulfonic acid (PFOS) are synthetic water pollutants and have accumulated in environments for decades, causing a serious global health issue. Conventional assays rely on liquid chromatography and mass spectroscopy that are very expensive and complicated and thus limit the large-scale monitoring of PFOS in wastewater. To achieve low-cost and accurate detection of PFOS, we designed a paper-based sensor with molecularly imprinted polyaniline electrodes that have recognition sites specific to PFOS.
View Article and Find Full Text PDFThis article introduces a gel-based separation-free point-of-care (POC) device for whole blood glucose colorimetric detection. Enzymes and a chromogenic substrate needed for colorimetric detection of glucose were entrapped in a photopolymerized poly(ethylene) glycol diacrylate (PEG-DA) hydrogel that was cast-molded into a circular shape. Our method enables colorimetric detection without the need for preseparation of blood plasma as the nanometer-scale three-dimensional porous structure of the hydrogel allows the diffusion of small analytes such as glucose while blocking the much larger blood cells.
View Article and Find Full Text PDFA low-cost and enzyme-free glucose paper sensor is presented as a promising alternative to glucose test strips. This paper-based glucose sensor is prepared with molecularly imprinted (MIP) polyaniline (PANI) electrode. The determination of glucose concentrations was studied by the impedance change of the paper sensor before and after the blood samples dispensing at a low frequency.
View Article and Find Full Text PDFThe perception of color is an internal label for the inferred spectral reflectance of visible surfaces. To study how spectral representation is transformed through modular subsystems of successive cortical areas, we undertook simultaneous optical imaging of intrinsic signals in macaque V1, V2, and V4, supplemented by higher-resolution electrophysiology and two-photon imaging in awake macaques. We find a progressive evolution in the scale and precision of chromotopic maps, expressed by a uniform blob-like architecture of hue responses within each area.
View Article and Find Full Text PDFExtracellular vesicles (EVs) play an important role in intercellular communication. Recently, there has been increasing interest in EVs as potential diagnostic biomarkers and therapeutic vehicles. However, the molecular properties and cargo information of EV subpopulations have not yet been fully investigated due to lack of reliable and reproducible EV separation technology.
View Article and Find Full Text PDFObjectives: Zika virus (ZIKV) is a mosquito-borne that re-emerged in 2015. The association between ZIKV and neurological complications initiated the development of relevant animal models to understand the mechanisms underlying ZIKV-induced pathologies. Transient inhibition of the type I interferon (IFN) pathway through the use of an IFNAR1-blocking antibody, MAR1-5A3, could efficiently permit active virus replication in immunocompetent animals.
View Article and Find Full Text PDFJAMA Otolaryngol Head Neck Surg
June 2020
For the hundreds of millions of worldwide diabetic patients, glucose test strips are the most important and commonly used tool for monitoring blood glucose levels. Commercial test strips use glucose oxidases as recognition agents, which increases the cost and reduces the durability of test strips. To lower the cost of glucose sensors, we developed a paper-based electrical sensor with molecularly imprinted glucose recognition sites and demonstrated the determination of various glucose concentrations in bovine blood solutions.
View Article and Find Full Text PDFExosomes are nanosized extracellular vesicles that play a significant role in cell-cell communication. Recently, there is significant interest in exosome-related fundamental research, especially subgroups of exosomes as potential biomarkers for cancer diagnosis and prognosis. In this paper, we report a new size selective isolation method via elastic lift force and nanomembrane filtration and demonstrated the liposome recovery rate of 92.
View Article and Find Full Text PDFPer- and poly-fluoroalkyl substances (PFASs) are man-made chemicals that are toxic and widely detected in the environment, including drinking water sources. A cost-effective treatment process for PFASs is currently not available. We developed reusable hydrogel sorbents to remove long- and short-chain perfluoroalkyl acids and 2,3,3,3-tetrafluoro-2-(heptafluoropropoxy)propanoic acid (GenX), which is are emerging PFAS.
View Article and Find Full Text PDFStudying the mismatch between perception and reality helps us better understand the constructive nature of the visual brain. The Pinna-Brelstaff motion illusion is a compelling example illustrating how a complex moving pattern can generate an illusory motion perception. When an observer moves toward (expansion) or away (contraction) from the Pinna-Brelstaff figure, the figure appears to rotate.
View Article and Find Full Text PDFHow primates perceive objects along with their detailed features remains a mystery. This ability to make fine visual discriminations depends upon a high-acuity analysis of spatial frequency (SF) along the visual hierarchy from V1 to inferotemporal cortex. By studying the transformation of SF across macaque parafoveal V1, V2, and V4, we discovered SF-selective functional domains in V4 encoding higher SFs up to 12 cycles/°.
View Article and Find Full Text PDF