Publications by authors named "Zhen-Jia Cheng"

CdE (E = S, Se) quantum dots (QDs) with a broad and large Stokes shift PL emission have emerged as potential materials for white-light LEDs. However, this surface-related emission of nanocrystals is currently limited by low quantum efficiency. Herein, a convenient noninjected one-pot method at a relatively low temperature to prepare CdS QDs was readily achieved.

View Article and Find Full Text PDF

A compact system for single-shot sequential holographic imaging (SSSHI) with high temporal resolution and a large field of view is proposed. In this system, a specially designed sequence pulse train generator with a group of diffractive gratings inserted is adopted to simultaneously generate the probe pulse train and the reference pulse train required for recording a single-shot spatial frequency division multiplexing hologram. The system successfully overcomes the walk-off effect of the ultrashort pulse laser in SSSHI and, hence, effectively avoids the influence of the short coherence of ultrashort pulses on the spatial resolution (or field of view) of SSSHI; the complexity of the system and the difficulty in the precise synchronous alignment of the probe and the reference pulses also can be greatly reduced.

View Article and Find Full Text PDF

A method for realizing 2D single-shot measurements of birefringence parameters (including both retardation and optic axis orientation) of anisotropic materials using a simple recording setup and an efficient processing algorithm is proposed. The recording setup can be built simply by inserting a circular polarizer and a polarization beam splitter, respectively, in the object path and reference path of a conventional off-axis holographic imaging system, with no need for other adjustments. An algorithm for quantitatively retrieving the birefringence parameters from one single-shot hologram is proposed and demonstrated, in which a new quantity describing the birefringence, called complex birefringence parameter, is introduced, and a set of formulas used to extract the birefringence parameters is derived.

View Article and Find Full Text PDF

We propose a quantitative phase imaging system with exact slightly-off-axis configuration and suitable for objects both smaller and larger than the size of the effective recording region of the image sensors. In this system, the object is illuminated by a convergent spherical beam and a specially designed aperture filter is placed on the spatial frequency plane of the object wave; at the same time, a point source emitting from the edge of the aperture is taken as the reference beam, so that the optimal frequency condition for reconstruction of slightly-off-axis digital holograms can be always guaranteed for both large and small objects as well as different magnification (or the field of view) configurations. At the same time, a 1x2 single-mode optical fiber splitter is used for generating the reference and the illumination beams.

View Article and Find Full Text PDF

We propose a double-channel angular-multiplexing polarization holographic imaging system with common-path and off-axis configurations. In the system, its input plane is spatially divided into three windows: an object window and two reference windows, and two orthogonal linear polarizers are attached, respectively, on the two reference windows; a two-dimensional cross grating is inserted between the input and output planes of the system. Thus the object beam passing through the object window and the two orthogonal polarized reference beams passing through the two reference windows can overlap each other at the output plane of the system and form a double-channel angular-multiplexing polarization hologram (DC-AM-PH).

View Article and Find Full Text PDF

A time-resolved holographic polarization microscopy, based on angular multiplexing holographic technique, is proposed for imaging ultrafast phenomena in polarization-sensitive transparent materials. This method can retrieve and image the complex amplitude distributions of two orthogonal polarization components of two sequential vector wavefronts with ultrashort time interval by a single short recording. Some experimental results for imaging the pulse laser induced ultrafast events based on the method are given.

View Article and Find Full Text PDF

We proposed an iterative method for phase retrieval and diffractive imaging based on Babinet's principle and complementary random sampling (CRS). We demonstrated that the whole complex amplitude (not sieved) of an object wave can be accurately retrieved from the diffraction intensities of the object wave sampled by a group of binary CRS masks and the diffractive imaging for the object can be realized through a single digital inverse diffraction. Some experimental results are given for the demonstration.

View Article and Find Full Text PDF

A simple and practical system for generation of vector beams with arbitrary polarization and complex-amplitude distributions is proposed. The system mainly consists of a scalar computer-generated hologram (CGH), a small-angle birefringent beam splitter (BBS), and a Fourier lens with a filtering aperture (FA). The CGH is placed in front of the Fourier lens.

View Article and Find Full Text PDF