Publications by authors named "Zhehao Hu"

Article Synopsis
  • The study introduces a new MR Multitasking (MT) technique designed to enhance radiotherapy treatment planning for abdominal sites by providing motion-resolved and multi-contrast images in a single scan.
  • The MT technique employs advanced imaging methods to accurately capture motion and structural details, showing promising results in both digital simulations and real patient studies, with favorable correlations to traditional imaging methods.
  • Initial clinical evaluations indicate that the MT technique allows for effective target delineation, suggesting that it could simplify and improve the abdominal radiotherapy planning process.
View Article and Find Full Text PDF

Purpose: Widely used conventional 2D T * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T * technique that enables rapid whole-heart coverage was developed and validated.

Methods: A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T * imaging.

View Article and Find Full Text PDF

Purpose: To extend the MR MultiTasking-based Multidimensional Assessment of Cardiovascular System (MT-MACS) technique with larger spatial coverage and water-fat separation for comprehensive aortocardiac assessment.

Methods: MT-MACS adopts a low-rank tensor image model for 7D imaging, with three spatial dimensions for volumetric imaging, one cardiac motion dimension for cine imaging, one respiratory motion dimension for free-breathing imaging, one T2-prepared inversion recovery time dimension for multi-contrast assessment, and one T2*-decay time dimension for water-fat separation. Nine healthy subjects were recruited for the 3T study.

View Article and Find Full Text PDF

Purpose: To develop an MR multitasking-based dynamic imaging for cerebrovascular evaluation (MT-DICE) technique for simultaneous quantification of permeability and leakage-insensitive perfusion with a single-dose contrast injection.

Methods: MT-DICE builds on a saturation-recovery prepared multi-echo fast low-angle shot sequence. The k-space is randomly sampled for 7.

View Article and Find Full Text PDF

Intracardiac thrombus in the left atrium and atrial appendage (LA/LAA) and left ventricle (LV) increases the risk of systemic thromboembolism and causes potentially devastating diseases such as ischemic stroke and acute ischemia in abdominal organs and lower extremities. Detecting the presence and monitoring the resolution of left heart intracardiac thrombus are of vital importance for stratifying patients and guiding treatment decisions. Currently, echocardiography is the most frequently used method for the above clinical needs, followed by computed tomography.

View Article and Find Full Text PDF

To develop and test the feasibility of a novel Single ProjectIon DrivEn Real-time Multi-contrast (SPIDERM) MR imaging technique that can generate real-time 3D images on-the-fly with flexible contrast weightings and a low latency.In SPIDERM, a 'prep' scan is first performed, with sparse k-space sampling periodically interleaved with the central k-space line (navigator data), to learn a subject-specific model, incorporating a spatial subspace and a linear transformation between navigator data and subspace coordinates. A 'live' scan is then performed by repeatedly acquiring the central k-space line only to dynamically determine subspace coordinates.

View Article and Find Full Text PDF

The aim of this study is to simultaneously quantify T1/T2 across three slices of the left-ventricular myocardium without breath-holds or ECG monitoring, all within a 3 min scan. Radial simultaneous multi-slice (SMS) encoding, self-gating, and image reconstruction was incorporated into the cardiovascular magnetic resonance (CMR) Multitasking framework to simultaneously image three short-axis slices. A T2prep-IR FLASH sequence with two flip angles was designed and implemented to allow B1+-robust T1 and T2 mapping.

View Article and Find Full Text PDF

Purpose: (1) To investigate the effect of internal localized movement on 3DMR intracranial vessel wall imaging and (2) to develop a novel motion-compensation approach combining volumetric navigator (vNav) and self-gating (SG) to simultaneously compensate for bulk and localized movements.

Methods: A 3D variable-flip-angle turbo spin-echo (ie, SPACE) sequence was modified to incorporate vNav and SG modules. The SG signals from the center k-space line are acquired at the beginning of each TR to detect localized motion-affected TRs.

View Article and Find Full Text PDF

Purpose: To develop an MR multitasking-based multidimensional assessment of cardiovascular system (MT-MACS) with electrocardiography-free and navigator-free data acquisition for a comprehensive evaluation of thoracic aortic diseases.

Methods: The MT-MACS technique adopts a low-rank tensor image model with a cardiac time dimension for phase-resolved cine imaging and a T -prepared inversion-recovery dimension for multicontrast assessment. Twelve healthy subjects and 2 patients with thoracic aortic diseases were recruited for the study at 3 T, and both qualitative (image quality score) and quantitative (contrast-to-noise ratio between lumen and wall, lumen and wall area, and aortic strain index) analyses were performed in all healthy subjects.

View Article and Find Full Text PDF