Publications by authors named "Zhaofan Yang"

The complexity of the tumor microenvironment (TME) severely hinders the therapeutic effects of various cancer treatment modalities. The TME differs from normal tissues owing to the presence of hypoxia, low pH, and immune-suppressive characteristics. Modulation of the TME to reverse tumor growth equilibrium is considered an effective way to treat tumors.

View Article and Find Full Text PDF

Low-potential electrochemiluminescence (ECL) luminophores with excellent ECL behavior have attracted considerable interest in biological analysis. Herein, we explored the ECL behavior of ZnTPP with different aggregates for the first time. In this work, we used the mixed solvent method to prepare the H- and J-aggregates of zinc tetraphenylporphyrin (ZnTPP).

View Article and Find Full Text PDF

Highly efficient detection in the aqueous phase for water-insoluble organic molecule probes is challenging. The bright aggregated-state electrochemiluminescence (ECL) of 1,1-disubstituted 2,3,4,5-tetraphenylsiloles by a co-reactant approach was discovered, and a heterogeneous aggregation-induced emission ECL (HAIE-ECL) was constructed at the electrode surface, showing very high ECL efficiency (37.8 %) and selective recognition for industrially important DNBP plasticizer with a low detection limit of 0.

View Article and Find Full Text PDF

We provide evidence of oxygen-involved electrochemiluminescence (ECL) of metal-free porphyrins and metalloporphyrins first. O and OH, which are oxygen intermediates, are indispensable for the formation of excited porphyrins, which has been proven by trapping free radical strategies. The wide differences regarding emission location and mechanism between metal-free porphyrins [including meso-tetra(4-methoxyphenyl)porphine (HTMPP), meso-tetraphenylporphyrin (HTPP), and meso-tetra(4-carboxyphenyl)porphine (HTCPP)] and metalloporphyrins (MTPP) depend on whether protons are present in the center of the porphin ring.

View Article and Find Full Text PDF

How to improve the accuracy of target detection substance in low-content and complex of real sample, which is still a major challenge in the analysis field. There is no doubt that the internal standard method is the best choice in the analysis methods. The internal standard method of ECL strategy can furnish more accurate detection results in the changeable complex environment, and it can dispel the primary vaguest interference in the system through the self-calibration of two emission spectra.

View Article and Find Full Text PDF