Publications by authors named "Zhaobo He"

Acid copper electroplating stands as a core technology in advanced packaging processes, facilitating the realization of metal interconnects, bumps, vias, and substrate wiring between transistors. The deposition quality of copper interconnect materials has a crucial impact on the final performance of chips, directly influencing their yield, reliability, and stability. In this intricate process, additives play a pivotal role in regulating the deposition quality and behavior of metal copper.

View Article and Find Full Text PDF

The copper connectivity technique is essential for achieving electrical interconnection in wafer level packaging (WLP), system in packaging (SiP), and 3D packaging. The essential processing material for copper connectivity is a copper sulfate electroplating solution in which organic additives play a crucial role in the regularity of copper electrodeposition. In this study, electrochemical tests, X-ray diffraction, 3D profiling, and scanning electron microscopy were used to investigate the leveling effect and mechanism of polyquaternary ammonium urea-containing polymer (PUB2) in the process of copper electrodeposition on-chip copper connections.

View Article and Find Full Text PDF

Non-invasive prenatal diagnostics (NIPD) has been an emerging field for prenatal diagnosis research. Carrying the whole genome coding of the fetus, fetal nucleated red blood cells (FNRBCs) have been pursued as a surrogate biomarker traveling around in maternal blood. Here, by combining a unique microbead-based centrifugal separation and enzymatic release, we demonstrated a novel method for FNRBC isolation from the blood samples.

View Article and Find Full Text PDF

Circulating tumor cells (CTCs) are a burgeoning topic in cancer biomarker discovery research with minimal invasive blood draws. CTCs can be used as potential biomarkers for disease prognosis, early cancer diagnosis and pharmacodynamics. However, the extremely low abundance of CTCs limits their clinical utility because of technical challenges such as the isolation and subsequent detailed molecular and functional characterization of rare CTCs from patient blood samples.

View Article and Find Full Text PDF

Detection of detached fetal nucleated red blood cells (fNRBCs) in the maternal peripheral blood may serve as a prospective testing method competing with the cell-free DNA, in non-invasive prenatal testing (NIPT). Herein, we introduce a facile and effective lab-on-a-chip method of fNRBCs detection using a capture-releasing material that is composed of biotin-doped polypyrrole nanoparticles. To enhance local topographic interactions between the nano-components and fNRBC, a specific antibody, CD147, coated on the nanostructured substrate led to the isolation of fNRBCs from maternal peripheral blood.

View Article and Find Full Text PDF

Cell-free DNA has been widely used in non-invasive prenatal diagnostics (NIPD) nowadays. Compared to these incomplete and multi-source DNA fragments, fetal nucleated red blood cells (fNRBCs), once as an aided biomarker to monitor potential fetal pathological conditions, have re-attracted research interest in NIPD because of their definite fetal source and the total genetic information contained in the nuclei. Isolating these fetal cells from maternal peripheral blood and subsequent cell-based bio-analysis make maximal genetic diagnosis possible, while causing minimal harm to the fetus or its mother.

View Article and Find Full Text PDF

Upconversion nanoparticles (UCNPs), with fascinating optical and chemical features, are a promising new generation of fluorescent probes. Although UCNPs have been widely used in diagnosis and therapy, there is an unmet need for a simple and effective surface engineering method that can produce cancer-targeting UCNPs. Here, we show that by coating particles with macrophage membranes, it becomes possible to utilize the adhesion between macrophages and cancer cells for effective cancer targeting.

View Article and Find Full Text PDF

In this paper, autofluorescent gelatin nanoparticles were synthesized as matrix metalloproteinase (MMP) responsive probes for cancer cell imaging. A modified two-step desolvation method was employed to generate these nanoparticles whose size was controllable and had stable autofluorescence. As glutaraldehyde was introduced as the crosslinking agent, the generation of Schiff base (CN) and double carbon bond (CC) between glutaraldehyde and gelatin endowed these gelatin nanoparticles distinct autofluorescence.

View Article and Find Full Text PDF

Microfluidics-based circulating tumor cell (CTC) isolation is achieved by using gelatin-coated silica microbeads conjugated to CTC-specific antibodies. Bead-binding selectively enlarges target cell size, providing efficient high-purity capture. CTCs captured can be further released non-invasively.

View Article and Find Full Text PDF

Background: Capture and identification of circulating tumor cells (CTCs) in the blood system can help guide therapy and predict the prognosis of cancer patients. However, simultaneous capture and identification of CTCs with both epithelial and mesenchymal phenotypes remains a formidable technical challenge for cancer research. This study aimed at developing a system to efficiently capture and identify these CTCs with heterogeneous phenotypes using transparent nanomaterials and quantum dots (QDs)-based multiplexed imaging.

View Article and Find Full Text PDF

For decades, poly(ethylene glycol) (PEG) has been widely incorporated into nanoparticles for evading immune clearance and improving the systematic circulation time. However, recent studies have reported a phenomenon known as "accelerated blood clearance (ABC)" where a second dose of PEGylated nanomaterials is rapidly cleared when given several days after the first dose. Herein, we demonstrate that natural red blood cell (RBC) membrane is a superior alternative to PEG.

View Article and Find Full Text PDF

As "liquid biopsies", circulating tumor cells (CTCs) have been thought to hold significant insights for cancer diagnosis and treatment. Despite the advances of microfluidic techniques that improve the capture of CTCs to a certain extent, recovering the captured CTCs with enhanced purity at the same time remains a challenge. Here, by combining on-chip purification and off-chip enzymatic treatment, we demonstrate a two-stage strategy to enhance the purity of captured cancer cells from blood samples.

View Article and Find Full Text PDF

Circulating tumor cells (CTCs) in the blood which have detached from both the primary tumor and any metastases may be considered as a "liquid biopsy" and are expected to replace tumor biopsies in the monitoring of treatment response and determining patient prognosis. Here, we introduce a facile and efficient CTC detection material made of hydroxyapatite/chitosan (HA/CTS), which is beneficial because of its transparency and excellent biological compatibility. Atomic force microscopy images show that the roughness of the HA/CTS nanofilm (HA/CTSNF) substrates can be controlled by changing the HA:CTS ratio.

View Article and Find Full Text PDF

A CTCs detection assay using transparent MnO2 nanospheres thin films to capture and release of CTCs is reported. The enhanced local topography interaction between extracellular matrix scaffolds and the antibody-coated substrate leads to improved capture efficiency. CTCs captured from artificial blood sample can be cultured and released, represent a new functional material capable of CTCs isolation and culture for subsequent studies.

View Article and Find Full Text PDF

We demonstrate the isolation of circulating tumor cells (CTCs) with a biocompatible nano-film composed of TiO2 nanoparticles. Due to the enhanced topographic interaction between nano-film and cancer cell surface, cancer cells (HCT116) spiked into PBS and healthy blood can be recovered from the suspension, whose efficiencies were respectively 80 % and 50 %. Benifit from the biocompatibility of this nano-film, in-situ culture of the captured cancer cells is also available, which provides an alternative selection when the capture cell number was inadequate or the sample cannot be analyzed immediately.

View Article and Find Full Text PDF