Background: Precise measurement of the intraosseous corridor within the superior pubic ramus is essential for the accurate percutaneous placement of a retrograde superior ramus screw (SRS). However, conventional manual measurement methods are often subjective, leading to variations in results among observers. Our goal was to develop an automated and dependable method for determining the retrograde SRS corridor.
View Article and Find Full Text PDFTo realize strong donor-acceptor face-to-face stacking for efficient through-space charge transfer-type thermally activated delayed fluorescence, a conceptually new design strategy is proposed to couple flexible bridges with adequate rigidity via built-in intramolecular hydrogen bonds (IHBs). The resulting emitter ACE-CN has a planarized benzyl methyl ether bridge self-anchored by the C-H···O IHB and shows a high photoluminescence quantum efficiency of 93%. The solution- and vacuum-processed devices exhibited high external quantum efficiencies of 11.
View Article and Find Full Text PDFObjective: Surgical treatment with internal fixation, specifically percutaneous fixation with three cannulated compression screws (CCSs), is the preferred choice for young and middle-aged patients. The mechanical advantage of the optimal spatial configuration with three screws provides maximum dispersion and cortical support. We suspect that the spatial proportion of the oblique triangle configuration (OTC) in the cross-section of the femoral neck isthmus (FNI) may significantly improve shear and fatigue resistance of the fixed structure, thereby stabilizing the internal fixation system in femoral neck fracture (FNF).
View Article and Find Full Text PDFBackground: Activating signal cointegrator 3 (ASCC3) has been identified as an oncogenic factor that impairs host immune defense. However, the underlying mechanisms of carcinogenesis and its impact on the antitumor immune response remain unclear. In this study, we aimed to investigate the molecular mechanisms of ASCC3 in the progression of non-small cell lung cancer (NSCLC).
View Article and Find Full Text PDFHepatobiliary Pancreat Dis Int
December 2022
Purpose: This study was to test the hypothesis that intramedullary (IM) nailing fixation of midshaft clavicle fractures could result in better clinical outcomes and lower complications rates than plating fixation.
Methods: PubMed, Embase, and the Cochrane Library database were used to search all English language published randomized controlled trials (RCTs) of midshaft clavicle fractures using plating versus IM nailing. The characteristics of the study participants were collected.
Closed reduction and internal fixation with three cannulated compression screws is a common method for treating femoral neck fractures in young and middle-aged patients. Protocols including the inverted triangle configuration and dispersion of the screws still needed further supports. The purpose of this study was to explore a novel oblique triangle configuration (OTC) of three screws in fixing femoral neck fractures based on the morphology of the femoral neck isthmus (FNI).
View Article and Find Full Text PDFBackground: The cross-sectional area of three parallel screws might affect the stability of the internal fixation of femoral neck fractures. The screws fixed in the oblique-triangle configuration (OTC) were assumed to have a larger cross-sectional area, but the biomechanical stability has not yet been validated. In this study, finite element analyses were performed to compare the biomechanical properties of the internal fixation fixed by the OTC and the traditional Inverted Equilateral Triangle Configuration (IETC).
View Article and Find Full Text PDFObjectives: To investigate the cross-section shape of the femoral neck isthmus (FNI) in three-dimensional reconstruction model of the femoral neck.
Methods: From December 2009 to December 2012, computed tomography (CT) data of bilateral hip joint from 200 consecutive patients (137 males and 63 females, 69.41 ± 9.
Objective: A3 intertrochanteric fracture is an extremely unstable fracture, which is often treated with intramedullary nail, but the implant failure is common due to the posterior medial fragment cannot be reconstructed. A new medial sustainable nail (MSN-Ⅱ) which can reconstruct the femoral medial support by sustainable screw was introduced in this study. The mechanical effect was verified by biomechanical experiment.
View Article and Find Full Text PDFPurpose: A hybrid pedicle screw system for minimally invasive spinal fixation was developed based on the uniplanar pedicle screw construct and a new intermediate screw. Its biomechanical performance was evaluated using finite element (FE) analysis.
Methods: A T12-L2 FE model was established to simulate the L1 vertebral compression fracture with Magerl classification A1.
Background: The reverse obliquity inter-trochanteric fracture is a distinct fracture pattern that is mechanically different from most inter-trochanteric fractures and the optional treatment of it is still controversial. The purpose of this study was to compare differences in the efficacy of a novel nail (medial support nail [MSN-II]) and proximal femoral nail anti-rotation (PFNA-II) in the treatment of reverse obliquity inter-trochanteric fractures (Arbeitsgemeinschaft fur Osteosynthesfrogen/Orthopedic Trauma Association [AO/OTA] 31-A3.1) using finite-element analysis.
View Article and Find Full Text PDFBackground: The femoral neck torsion angle (FNTA) is an important but often neglected parameter in assessments of the anatomical morphology of the femoral neck, which is often confused with the femoral neck anteversion angle (FNAA) in the current literature. Currently, the measurement methods reported in the literature all adopt the naked eye or two-dimensional (2D) visualization method, and the measurement parameters and details are not clearly defined. The objection of this research was to provide a reliable 3D method for determining the femoral neck axis, to improve the measurement method of the FNTA, and to analyze the anatomical and clinical significance of the results.
View Article and Find Full Text PDFOptimal acetabular cup orientation is of substantial importance to good long-term function and low complication rates after total hip arthroplasty (THA). The radiographic anteversion (RA) and inclination (RI) angles of the cup are typically studied due to the practicability, simplicity, and ease of interpretation of their measurements. A great number of methods have been developed to date, most of which have been performed on pelvic or hip anteroposterior radiographs.
View Article and Find Full Text PDFBackground: Available research about the anatomic patterns of intertrochanteric fractures is lacking, and fracture mapping has not previously been performed on intertrochanteric fractures. This study aimed to determine the major trajectories of intertrochanteric fracture lines using computed tomography data from a series of surgically treated patients.
Methods: In this study, 504 patients with intertrochanteric fractures were retrospectively analyzed.
Robots in orthopedic surgery have been developed rapidly for decades and bring significant benefits to the patients and healthcare providers. However, robotics in fracture reduction remains at the infant stage. As essential components of the current robotic system, external fixators were used in fracture reduction, including the unilateral and Ilizarov-like ring fixators.
View Article and Find Full Text PDFObjective: To assess the differences in bone mineral density (BMD) and hip geometry in trochanteric and cervical hip fractures in elderly Chinese patients.
Methods: A consecutive series of 196 hip fracture patients aged over 50 years was recruited from November 2013 to October 2015, including 109 cases of cervical fractures (36 males and 73 females) and 87 cases of trochanteric fractures (34 males and 53 females). All patients were evaluated through dual-energy X-ray absorptiometry, and baseline characteristics, BMD and structural parameters were collected and reviewed.
Purpose: The optimal closed reduction technique for unstable pelvic fractures remains controversial. The purpose of this study is to verify the effectiveness and report early experiences with the reduction of unstable pelvic fractures using a computer-aided pelvic reduction frame.
Methods: From January 2015 to August 2016, a total of 10 patients with unilateral unstable pelvic fractures were included in this study.
Previous studies have reported age-specific pathological and functional outcomes in young and aged patients suffering spinal cord injury, but the mechanisms remain poorly understood. In this study, we examined mice with spinal cord injury. Gene expression profiles from the Gene Expression Omnibus database (accession number GSE93561) were used, including spinal cord samples from 3 young injured mice (2-3-months old, induced by Impactor at Th9 level) and 3 control mice (2-3-months old, no treatment), as well as 2 aged injured mice (15-18-months old, induced by Impactor at Th9 level) and 2 control mice (15-18-months old, no treatment).
View Article and Find Full Text PDF