To assess the effect of 10% carbamide peroxide (CP) and 6% hydrogen peroxide (HP) home bleaching agents on the translucency and color of monolithic zirconia. Ninety disc specimens were fabricated (diameter, 10 mm) from multi-layered (ML), ultra translucent multi-layered (UTML), and super translucent multi-layered (STML) zirconia blocks at three thicknesses (0.4,1,1.
View Article and Find Full Text PDFObjective: To evaluate the effect of adjustment and finishing procedures and thermal aging of monolithic zirconia on the surface roughness, phase transformation, and flexural strength.
Material And Methods: One hundred disk-shaped monolithic zirconia specimens were randomly divided into 5 groups: control, received only glazing; group Gr, was grinded; group GrP, was grinded and polished; group GrG, was grinded and re-glazed; group GrPG, was re-glazed after grinding and polishing. Half of the each group were stored in distilled water for 24 h and the remaining were thermocycled for 5000 cycles.
Background: There are studies that examined the effect of staining on the surface properties of composite resins, using different solutions and bleaching applications. However, the effect of both staining and bleaching on the same composite specimens is an issue that needs to be investigated.
Objectives: The aim of this study was to investigate the surface microhardness, roughness and color changes (ΔE) of 2 different composite resins after staining and bleaching.
Contemp Clin Dent
January 2019
Background: Routine laboratory procedures and repeated glazed effect the final color of metal-ceramic restorations (MCRs). Clinicians wonder if the color changes after routine laboratory procedures and repeated glazed is clinically acceptable or not.
Aims: The aim of this study was to determine the color changes of MCRs after routine laboratory procedures and then glazed for 1, 2, and 3 times.
Background: For successful restoration, it is necessary to minimize the microleakage between dentin and the composite material.
Objectives: The purpose of this study was to evaluate the microleakage of 2 different resin cements (self-adhesive and conventional) on dentin treated with acid, sodium hypochlorite (NaOCl), the acid-NaOCl mixture, the erbium-doped yttrium aluminum garnet (Er:YAG) laser, and their combination.
Material And Methods: Seventy dentin specimens were divided into 7 groups (n = 10) according to the surface treatment.
J Indian Prosthodont Soc
January 2017
Purpose: The aim of this study was to assess the intra-pulpal temperature changes in adhesive resin cements during polymerization.
Materials And Methods: Dentin surface was prepared with extracted human mandibular third molars. Adhesive resin cements (Panavia F 2.
The purpose of this study was to investigate the effect of ultrafast fiber laser treatment on the bond strength between titanium and resin cement. A total of 60 pure titanium discs (15 mm × 2 mm) were divided into six test groups (n = 10) according to the surface treatment used: group (1) control, machining; group (2) grinding with a diamond bur; group (3) ultrafast fiber laser application; group (4) resorbable blast media (RBM) application; group (5) electro-erosion with copper; and group (6) sandblasting. After surface treatments, resin cements were applied to the treated titanium surfaces.
View Article and Find Full Text PDFThe aim of this study was to evaluate the effects of systemic fucoxanthin treatment on alveolar bone resorption in rats with periodontitis. Thirty rats were divided into control, experimental periodontitis (EP), and experimental periodontitis-fucoxanthin (EP-FUCO) groups. Periodontitis was induced by ligature for four weeks.
View Article and Find Full Text PDFStatement Of Problem: A soft lining is applied under a removable prosthesis for various reasons. The porosity of the lining material may increase colonization by microorganisms and cause tissue inflammation.
Purpose: The purpose of this in vitro study was to evaluate the effect of sealer coating on the surface roughness of soft lining materials under 4 different conditions.
This study evaluated the bond strength of different adhesive agents to TheraCal LC and mineral trioxide aggregate (MTA) and examined the morphologic changes of these materials with different surface treatments. A total of 120 specimens, 60 of MTA Angelus (AMTA), and 60 of TheraCal LC, were prepared and divided into six subgroups according to the adhesive agent used; these agents included Scotchbond Multipurpose, Clearfil SE Bond, Clearfil Protect Bond, Clearfil S Bond, OptiBond All-in-One, and G-aenial Bond. After application of adhesive agents, Filtek Z250 composite resin was placed onto the specimens.
View Article and Find Full Text PDFThis in vitro study evaluated the whitening effect of four different over-the-counter products compared with a 10% carbamide peroxide (CP) bleaching gel. Specimens obtained from bovine incisors were stained in a tea solution and randomly divided into six groups according to the product used (n=10): CT: conventional toothpaste (negative control); CWT: Crest 3D White toothpaste; CWR: Crest 3D White mouth rinse; CWS: Crest 3D White strips; DW: Dazzling White (paint-on gel); and OP: Opalescence PF 10% CP (at-home bleaching gel, positive control). Over-the-counter products and 10% CP were used according to the manufacturer's recommendations.
View Article and Find Full Text PDFStatement Of Problem: Failure of the bond between metal and ceramic is common with metal ceramic prostheses.
Purpose: The purpose of this in vitro study was to investigate how recasting affects the metal-ceramic bond strength for 1 base metal and 1 noble alloy compared with laser-sintered Co-Cr alloy by using a procedure based on ANSI/ADA Specification No. 38.
J Biomed Mater Res B Appl Biomater
July 2013
The aim of this study was to evaluate of flexural strength of some adhesive resin cements. Three dual-cure composite resin cements (Nexus 3; Variolink II, Panavia F) were prepared. The manufacturer's mixing directions for the cements were followed.
View Article and Find Full Text PDFObjective: The purpose of this study was to evaluate the microtensile bond strength of resin cement to a feldspathic ceramic after treating the surface with (a) hydrofluoric (HF) acid, (b) air abrasion, (c) Er:YAG laser irradiation, (d) Nd:YAG laser irradiation, and (e) HF acid etching after either air abrasion or laser irradiation.
Background Data: It is unknown whether the laser application or its combination with another treatment method can be used as a tool to roughen the surface of a feldspathic ceramic in order to increase the bond strength between the resin cement and ceramic surface.
Materials And Methods: Forty feldspathic ceramic blocks (Ceramco(TM)) were prepared and divided into eight equal groups (n = 5) according to the following surface treatments: no treatment; etching with 9.
Objective: The purpose of this study was to evaluate the shear bond strength of a repair composite resin to a feldspathic ceramic surface that had been either etched with 9.5% hydrofluoric acid (HFA), irradiated by an Er:YAG or Nd:YAG laser, or etched with 9.5% HFA after being irradiated by each laser type.
View Article and Find Full Text PDFIn this study, the surface hardness of five light-cured composite resins were evaluated, namely: filled (Estelite), nanofil (AElite), unfilled (Valux Plus), hybrid (Tetric ceram), and Ormocer-based (Admira) composite resins. The microhardness values of composite specimens were measured at the top and bottom surfaces after 24 hours or 30 days of immersion in different solutions (tea, coffee, Turkish coffee, mouthwash, cola, and distilled water). Comparisons were made with univariate analysis of variance and Duncan's multiple range test.
View Article and Find Full Text PDFThe aim of this study was to investigate and compare the temperature rises which occurred during the setting reactions of different permanent cements used to lute fixed partial prosthodontics. In this study, four cements were used. They were mixed in three different proportions: according to manufacturers' recommendations, at doubled powder ratio, and at doubled liquid ratio.
View Article and Find Full Text PDFEur J Prosthodont Restor Dent
September 2006
In this study the solubility, water sorption and the bond strength of auto-polymerising and heat-polymerising acrylic resins were investigated. Two auto-polymerising and five heat polymerising acrylic resin materials were used for this study. Thirty-five specimens were prepared (50 mm in diameter and 0.
View Article and Find Full Text PDFThis study assessed the plasma and blood concentrations of Cr, Co, and Ni among subjects using removable partial dentures. A comparison was made between subjects with and without RPD treatment history. Control group consisted of 10 healthy individuals without dentures.
View Article and Find Full Text PDFDetermination of the occlusal vertical dimension (OVD) is one of the most important steps in making dentures. Various techniques have been used to make these measurements. Unfortunately, there is no universally accepted method available for clinical use.
View Article and Find Full Text PDFObjective: In this study, the time-related pH changes that occur in cements having different structures were observed.
Method And Materials: Eight cements consisting of four permanent and four temporary cements were used. The materials were prepared according to manufacturers' instructions.
The purpose of this study was to evaluate the influence of a thickness and processing method on linear dimension change and water sorption in a denture base resin after storage in water for 24 hours, one week, and four weeks. Sixty wax specimens 65 mm long and 10 mm wide were fabricated in three thicknesses, 1.5, 3, and 4.
View Article and Find Full Text PDFPresent study the relation between pH, thermal changes and dimensional stability during setting of irreversible hydrocolloid impression materials was investigated. Ten specimens of each product were prepared for different measurements: Thermal, pH changes and dimensional stability (mass and linear). Thermal and pH readings for 20 min and dimensional measurements for a 2 hr period were taken after mixing.
View Article and Find Full Text PDF