Objectives: The radiographical process of projection of a complex human form onto a two-dimensional image plane gives rise to distortions and magnifications. It is important that any simulation used for educational purposes should correctly reproduce these. Images generated using a commercially available computer simulation widely used in radiography education (ProjectionVR) were tested for geometric accuracy of projection in all planes.
View Article and Find Full Text PDFWe report on a new articular cartilage imaging technique with potential for clinical arthroscopic use, by supplementing the variable-incidence-angle polarization-sensitive optical coherence tomography method previously developed by us with a conical beam scan protocol. The technique is validated on bovine tendon by comparing experimental data with simulated data generated using the extended Jones matrix calculus. A unique capability of this new optical technique is that it can locate the "brushing direction" of collagen fibers in articular cartilage, which is structural information that extends beyond established methods such as split-line photography or birefringent fast-axis measurement in that it is uniquely defined over the full azimuthal-angle range of (-π, + π).
View Article and Find Full Text PDFOptical coherence tomography (OCT) is a modern high resolution subsurface medical imaging technique. Herein we describe: (i) the synthesis of a thiophene-functionalized oligo(ethylene glycol) methacrylate (OEGMA)-based statistical copolymer, denoted poly(2TMOI-OEGMA); (ii) the preparation of sterically-stabilized polypyrrole (PPy) nanoparticles of approximately 60 nm diameter; (iii) the evaluation of these nanoparticles as a NIR-absorbing optical contrast agent for high-resolution OCT imaging. We show that poly(2TMOI-OEGMA)-stabilized PPy nanoparticles exhibit similar optical properties to poly(vinyl alcohol) (PVA)-stabilized PPy nanoparticles of comparable size prepared using commercially available PVA.
View Article and Find Full Text PDFWe report on a new calibration technique that permits the accurate extraction of sample Jones matrix and hence fast-axis orientation by using fiber-based polarization-sensitive optical coherence tomography (PS-OCT) that is completely based on non-polarization-maintaining fiber such as SMF-28. In this technique, two quarter-wave plates (QWPs) are used to completely specify the parameters of the system fibers in the sample arm so that the Jones matrix of the sample can be determined directly. The device was validated on measurements of a QWP and an equine tendon sample by a single-mode fiber-based swept-source PS-OCT system.
View Article and Find Full Text PDFWe demonstrate theoretically and experimentally that the phase retardance and relative optic-axis orientation of a sample can be calculated without prior knowledge of the actual value of the phase modulation amplitude when using a polarization-sensitive optical coherence tomography system based on continuous polarization modulation (CPM-PS-OCT). We also demonstrate that the sample Jones matrix can be calculated at any values of the phase modulation amplitude in a reasonable range depending on the system effective signal-to-noise ratio. This has fundamental importance for the development of clinical systems by simplifying the polarization modulator drive instrumentation and eliminating its calibration procedure.
View Article and Find Full Text PDFWe report results to verify a theoretical framework to analyze the 3D depth-wise structural organization of collagen fibers in articular cartilage using polarization-sensitive optical coherence tomography. Apparent birefringence data obtained from multi-angle measurements using a time domain polarization-sensitive optical coherence tomography system has been compared with simulated data based on the extended Jones matrix calculus. Experimental data has been shown to agree with the lamellar model previously proposed for the cartilage microstructure based on scanning electron microscopy data.
View Article and Find Full Text PDFOptical coherence tomography (OCT) is a noninvasive imaging methodology that is able to image tissue to depths of over 1 mm. Many epithelial conditions, such as melanoma and oral cancers, require an invasive biopsy for diagnosis. A noninvasive, real-time, point of care method of imaging depth-resolved epithelial structure could greatly improve early diagnosis and long-term monitoring in patients.
View Article and Find Full Text PDFA near-infrared (NIR) absorbing contrast agent based on polypyrrole nanoparticles is described. Quantitative optical coherence tomography studies on tissue phantoms and Mie scattering calculations indicate their potential application for early-stage cancer diagnosis.
View Article and Find Full Text PDFIn a biological tissue, light scattering is based on the size and type of scatterers seen as refractive index variations that describe the optical properties shown. In this paper, we have implemented the variable incidence angle technique of multiple angle of illumination experiment on tendon and cartilage samples whose dominant constituents are genetically different types of collagen fibers, type I and type II, respectively. It is found that tendon displays a much greater angular anisotropy in its optical backscattering coefficient than the healthy cartilage.
View Article and Find Full Text PDFWe present a phase fluctuation calibration method for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method uses a low-voltage broadband polarization modulator driven by a synchronized sinusoidal burst waveform rather than an asynchronous waveform, together with the removal of the global phases of the measured Jones matrices by the use of matrix normalization. This makes it possible to average the measured Jones matrices to remove the artifact due to the speckle noise of the signal in the sample without introducing auxiliary optical components into the sample arm.
View Article and Find Full Text PDFRecently the effects of reduced bit-depth acquisition on swept-source optical coherence tomography (SS-OCT) image quality have been evaluated by using simulations and empirical studies, showing that image acquisition at 8-bit depth allows high system sensitivity with only a minimal drop in the signal-to-noise ratio compared to higher bit-depth systems. However, in these studies the 8-bit data is actually 12- or 14-bit ADC data numerically truncated to 8 bits. In practice, a native 8-bit ADC could actually possess a true bit resolution lower than this due to the electronic jitter in the converter etc.
View Article and Find Full Text PDFWe describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions.
View Article and Find Full Text PDF