Publications by authors named "Zeinab A Elsherif"

Atorvastatin and ezetimibe are lipid-lowering drugs prescribed for the treatment of hypercholesterolemia. An LC-MS-MS method has been developed and validated for the simultaneous estimation of atorvastatin and ezetimibe in human plasma using pitavastatin as an internal standard. Liquid-liquid extraction was used for the purification and preconcentration of analytes from human plasma matrix.

View Article and Find Full Text PDF

Three stability-indicating assay methods were developed for the determination of tropisetron in a pharmaceutical dosage form in the presence of its degradation products. The proposed techniques are HPLC, TLC, and first-derivative spectrophotometry (1D). Acid degradation was carried out, and the degradation products were separated by TLC and identified by IR, NMR, and MS techniques.

View Article and Find Full Text PDF

Three stability-indicating methods were developed for the determination of racecadotril (RCT) in the presence of its alkaline degradation products. The first was an HPLC method in which efficient chromatographic separation was achieved on a C18 analytical column and a mobile phase of acetonitrile-methanol-water-acetic acid (52:28:20:0.1, v/v/v/v).

View Article and Find Full Text PDF

A simple sensitive, selective and accurate reversed-phase high performance liquid chromatographic method was developed and validated for the quantitative determination of lansoprazole, omeprazole and pantoprazole sodium sesquishydrate in the presence of their acid-induced degradation products. The three compounds were monitored at 280 nm using Nova-Pak C(18) column and a mobile phase consisting of 0.05 M potassium dihydrogen phosphate : methanol : acetonitrile (5 : 3 : 2 v/v/v).

View Article and Find Full Text PDF

Two reproducible stability indicating methods were developed for the determination of risperidone (RISP) in presence of its degradation products in pure form and in tablets. The first method was based on reversed phase high performance liquid chromatography (HPLC), on Lichrosorb RP C 18 column (250 mm i.d.

View Article and Find Full Text PDF

Two sensitive and reproducible methods were developed and validated for the determination of ziprasidone (ZIP) in the presence of its degradation products in pure form and in pharmaceutical formulations. The fi rst method was based on reversed-phase high-performance liquid chromatography (HPLC), on a Lichrosorb RP C(18) column using water:acetonitrile:phosphoric acid (76:24:0.5 v/v/v) as the mobile phase at a fl ow rate of 1.

View Article and Find Full Text PDF