A 78-year-old woman with diffuse large B-cell lymphoma was referred for an 18 F-FDG PET/CT to evaluate therapy response after 6 cycles of R-mini-CHOP. A new 18 F-FDG accumulation was noticed medial in the upper part of the right lower leg, spreading along the medial head of the gastrocnemius muscle. The shaft-bow-looking curvature, arch sign, of 18 F-FDG revealed a fluid collection on CT.
View Article and Find Full Text PDFCurrent dyslipidemia management in patients with atherosclerotic cardiovascular disease (ASCVD) is based on traditional serum lipids. Yet, there is some indication from basic research that serum apolipoproteins A-I, (a), B, C-I, C-II, C-III, and E may give better pathophysiological insight into the root causes of dyslipidemia. To facilitate the future adoption of clinical serum apolipoprotein (apo) profiling for precision medicine, strategies for accurate testing should be developed in advance.
View Article and Find Full Text PDFObjectives: In this paper, we describe the steps followed for the development of a certified reference material for immunoglobulin G antibodies against β2-glycoprotein I (also known as apolipoprotein H). These steps include processing of the material, commutability, the impact of dilution, the appropriate reconstitution conditions, homogeneity and stability during transport and storage.
Methods: We analysed 69 clinical samples from patients suffering from antiphospholipid syndrome with several commercial enzyme-linked immunosorbent assays (ELISA) purchased from in vitro diagnostic manufacturers.
Mediterr J Rheumatol
March 2019
Autoantibody measurement is the chosen tool, in addition to clinical observations, for the diagnosis of autoimmune diseases. Hence, it is essential for these measurements to be reliable and in the longer run to be standardised. Due to the intrinsic variability of analytes and reagents, and the heterogeneity of the available techniques, standardisation cannot be taken for granted, and results may vary between laboratories.
View Article and Find Full Text PDFBackground The importance of the standardisation of immunoassays for autoantibodies has been widely discussed. The appropriate use of certified reference materials (CRM) could contribute to a more accurate diagnosis and follow-up of a series of diseases such as small vessel-associated vasculitis. This is a systemic autoimmune disorder during which two autoantibodies can be present, MPO ANCA IgG and PR3 ANCA IgG.
View Article and Find Full Text PDFBackground: The core Alzheimer's disease cerebrospinal fluid (CSF) biomarkers total tau (T-tau), phosphorylated tau (P-tau), β-amyloid 1-42 (Aβ42) and β-amyloid 1-40 (Aβ40) are increasing in importance and are now part of the research criteria for the diagnosis of the disease. The main aim of this study is to evaluate whether a set of certified reference materials (CRMs) are commutable for Aβ42 and to serve as a feasibility study for the other markers. This property is a prerequisite for the establishment of CRMs which will then be used by manufacturers to calibrate their assays against.
View Article and Find Full Text PDFBackground: Measurement standardization of the catalytic concentration of α-amylase in serum is based on 3 pillars: the primary reference measurement procedure (PRMP), reference laboratories, and suitable certified reference materials (CRMs). Commutability is a prerequisite when using a CRM for calibration and trueness control of routine methods or for value transfer from the PRMP to end-user calibrators of routine methods through a calibration hierarchy.
Methods: We performed a commutability study with 30 serum pools and 5 candidate reference materials (RMs) for pancreatic α-amylase using an automated version of the PRMP and 5 different routine methods.
Commutability is a property of a reference material (RM) that relates to the closeness of agreement between results for an RM and results for clinical samples (CSs) when measured by ≥2 measurement procedures (MPs). Commutability of RMs used in a calibration traceability scheme is an essential property for them to be fit for purpose. Similarly, commutability of trueness controls or external quality assessment samples is essential when those materials are used to assess trueness of results for CSs.
View Article and Find Full Text PDFA serum Certified Reference Material (CRM) for supporting reliable autoimmune diagnostics was recently released by the Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre of the European Commission. It was produced in collaboration with a Working Group on the Harmonisation of Autoimmune Tests of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC WG-HAT). This material is aimed at facilitating the standardisation of measurements of anti-myeloperoxidase immunoglobulin G antibodies.
View Article and Find Full Text PDFThe 42 amino acid form of amyloid β (Aβ-) in cerebrospinal fluid (CSF) has been widely accepted as a central biomarker for Alzheimer's disease. Several immunoassays for CSF Aβ are commercially available, but can suffer from between laboratory and batch-to-batch variability as well as lack of standardisation across assays. As a consequence, no general cut-off values have been established for a specific context of use (e.
View Article and Find Full Text PDFThe detection and identification of botulinum neurotoxins (BoNT) is complex due to the existence of seven serotypes, derived mosaic toxins and more than 40 subtypes. Expert laboratories currently use different technical approaches to detect, identify and quantify BoNT, but due to the lack of (certified) reference materials, analytical results can hardly be compared. In this study, the six BoNT/A1-F1 prototypes were successfully produced by recombinant techniques, facilitating handling, as well as improving purity, yield, reproducibility and biosafety.
View Article and Find Full Text PDFBackground: The cerebrospinal fluid (CSF) amyloid-β (Aβ42) peptide is an important biomarker for Alzheimer's disease (AD). Variability in measured Aβ42 concentrations at different laboratories may be overcome by standardization and establishing traceability to a reference system. Candidate certified reference materials (CRMs) are validated herein for this purpose.
View Article and Find Full Text PDFIntroduction: Acquired angioedema is a rare disorder causing recurrent life-threatening angioedema, due to decreased activity of C1 esterase inhibitor.
Case Report: A 57-year-old man presented to our hospital with recurrent swelling of the hands, lips, tongue, scrotum and throat. Lab examination showed the presence of an IgM kappa monoclonal antibody.
The standardization of immunoassays for immunoglobulin (Ig)G myeloperoxidase-anti-neutrophil cytoplasmic antibodies (MPO-ANCA) could contribute to a more accurate diagnosis and follow-up of small vessels-associated vasculitis, a systemic autoimmune disorder that leads to necrosis of blood vessel walls. Despite significant efforts by different groups, the level of comparability of results from commercially available immunoassays used for IgG MPO-ANCA detection is still poor. Therefore, the potential for improvement using reference materials was assessed.
View Article and Find Full Text PDFIntroduction: Cerebrospinal fluid (CSF) amyloid-β 1-42 (Aβ42) is an important biomarker for Alzheimer's disease, both in diagnostics and to monitor disease-modifying therapies. However, there is a great need for standardization of methods used for quantification. To overcome problems associated with immunoassays, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has emerged as a critical orthogonal alternative.
View Article and Find Full Text PDFClin Chem Lab Med
May 2015
The concept of metrological traceability of measurement results to property values assigned to measurement standards of higher metrological order or to the International System of Units (SI) through sequential calibrations, using reference materials and reference measurement procedures, plays a key role in ensuring that end user measurement procedures perform at an acceptable level in the clinical context. The aim is that measurement results produced over time or by different end users or with different end user measurement procedures for the same measurand will be equivalent within their corresponding uncertainties. These goals can only be reached under certain conditions and if requirements laid down in international standards on calibration concepts, reference measurement procedures and reference materials are fulfilled.
View Article and Find Full Text PDFInternational standards for anti-beta2 glycoprotein I (anti-β2GPI) testing are needed. We evaluated the suitability of polyclonal/monoclonal candidate reference materials (RM) for the assay. IgG/IgM anti-β2GPI were affinity-purified (AP) from high-positive antiphospholipid syndrome sera and IgG from HCAL clone supernatant.
View Article and Find Full Text PDFBackground: Many different cystatin C-based equations exist for estimating glomerular filtration rate. Major reasons for this are the previous lack of an international cystatin C calibrator and the nonequivalence of results from different cystatin C assays.
Methods: Use of the recently introduced certified reference material, ERM-DA471/IFCC, and further work to achieve high agreement and equivalence of 7 commercially available cystatin C assays allowed a substantial decrease of the CV of the assays, as defined by their performance in an external quality assessment for clinical laboratory investigations.
Autoantibody measurement is an excellent tool to confirm the diagnosis of rheumatic autoimmune diseases. Hence, reliability and harmonization of autoantibody testing are essential, but these issues are still a matter of debate. Intrinsic variability in analytes and reagents as well as heterogeneity of the techniques are the main reasons for discrepancies in inter-laboratory variations and reporting of test results.
View Article and Find Full Text PDFBackground: Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material.
Methods: We performed a commutability study with 30 serum samples and the reference materials ERM-DA470, ERM-DA470k/IFCC, and ERM-DA472/IFCC, using 6 different methods.
Background: Human growth hormone (hGH) is measured for the diagnosis of secretion disorders. These measurements fall under the EU Directive 98/79/EC on in vitro diagnostic medical devices requiring traceability of commercial calibrator values to higher-order reference materials or procedures (Off J Eur Communities 1998 Dec 7;L 331:1-37). External quality assessment schemes show large discrepancies between results from different methods, even though most methods provide results traceable to the recommended International Standard (IS 98/574).
View Article and Find Full Text PDFBackground: Increased urinary excretion of albumin reflects kidney damage and is a recognized risk factor for progression of renal and cardiovascular disease. Considerable inter-method differences have been reported for both albumin and creatinine measurement results, and therefore the albumin-to-creatinine ratio. Measurement accuracy is unknown and there are no independent reference measurement procedures for albumin and no reference materials for either measurand in urine.
View Article and Find Full Text PDF