Publications by authors named "Zbigniew Tyminski"

The L6 chondritic meteorite, HaH-346, fell in Libya. However, neither the exact date of the fall nor the exact size of the original meteoroid or asteroid is known. A specimen of the meteorite, weighing 488 g, was measured using ultra low-background gamma-ray spectrometry in the 225 m deep underground facility HADES.

View Article and Find Full Text PDF

The gamma emitting impurities in Tc solution obtained from enriched molybdenum Mo metallic target after its irradiation in a cyclotron were measured using a high-purity germanium (HPGe) detector. The radioactivity range of tested samples of Tc was rather low, in the range from 0.34 to 2.

View Article and Find Full Text PDF

Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.

View Article and Find Full Text PDF

The standardisation of (111)In by 4π(LS)-γ coincidence and anticoincidence counting is presented. Absolute measurements were performed for samples with different concentrations of carrier solution and for different window settings in the gamma channel. The radioactive concentration of the master solution determined on the same reference date was consistent for all measurements performed.

View Article and Find Full Text PDF

Radionuclidic purity tests of (18)F radiopharmaceuticals (Na(18)F and fluorodeoxyglucose [(18)F]FDG) and radionuclide composition analysis of irradiated water [(18)O]H2O were performed. The measurements were conducted using a High-Purity Germanium (HPGe) detector and a liquid scintillation counter. Radionuclide identification and activity measurements were performed for samples from different stages of the production process.

View Article and Find Full Text PDF

The Radioisotope Centre POLATOM organized a proficiency test of activity measurements of (90)Y and (89)Sr with nuclear medicine departments in Polish hospitals. Radioactive solutions used in this exercise were standardized by the TDCR method using the measurement systems of the National Standard of Radionuclides Activity in Poland. Results were analysed in compliance with ISO/IEC 17043:2010 (ISO, 2010) by calculating z scores and ζ (zeta) scores.

View Article and Find Full Text PDF